RESIDENTIAL ELECTRICIAN EXAM #2
  • RESIDENTIAL ELECTRICIAN EXAM #2

  • Exam (elaborations) • 5 pages • 2024
  • The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches - Answer-C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) bathrooms - Answer-D: bathrooms Ref: 240.24(E) The MAXIMUM number of grounded conductors allowed to be terminated in an individual terminal,...
    (0)
  • $10.99
  • + learn more
Residential Electrician Exam #2 || Questions and Answer 100% Accurate
  • Residential Electrician Exam #2 || Questions and Answer 100% Accurate

  • Exam (elaborations) • 13 pages • 2024
  • Residential Electrician Exam #2 || Questions and Answer 100% Accurate Residential Electrician Exam #2 || Questions and Answer 100% Accurate The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches - ANSWER-C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) ...
    (0)
  • $11.49
  • + learn more
Residential Electrician Exam #1 || Questions and Answers 100% Correct
  • Residential Electrician Exam #1 || Questions and Answers 100% Correct

  • Exam (elaborations) • 11 pages • 2024
  • Residential Electrician Exam #1 || Questions and Answers 100% Correct Residential Electrician Exam #1 || Questions and Answers 100% Correct Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - ANSWER-A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) swi...
    (0)
  • $10.49
  • + learn more
RESIDENTIAL ELECTRICIAN EXAM #1 2024/2025 WITH 100% ACCURATE SOLUTIONS
  • RESIDENTIAL ELECTRICIAN EXAM #1 2024/2025 WITH 100% ACCURATE SOLUTIONS

  • Exam (elaborations) • 8 pages • 2024
  • RESIDENTIAL ELECTRICIAN EXAM #1 2024/2025 WITH 100% ACCURATE SOLUTIONS
    (0)
  • $16.49
  • + learn more
Residential Electrician Exam #1 Questions and Answers 100% Correct
  • Residential Electrician Exam #1 Questions and Answers 100% Correct

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #1 Questions and Answers 100% Correct Residential Electrician Exam #1 Questions and Answers 100% Correct Residential Electrician Exam #1 Questions and Answers 100% Correct Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only - ANSWER-A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, ge...
    (0)
  • $9.99
  • + learn more
Residential Electrician Exam #1Complete Questions With 100% Correct Answers.  Graded A+
  • Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Graded A+

  • Exam (elaborations) • 6 pages • 2024
  • Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Ferrous metal enclosures for grounding electrode conductors shall be _____. a) electrically continuous b) electrically isolated c) not permitted d) rigid metal conduit (RMC) only A: electrically continuous Ref: 250.64(E) Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. a) switched receptacles for cord-connected incandescent luminaires b) permanently...
    (0)
  • $9.59
  • + learn more
Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+
  • Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+

  • Exam (elaborations) • 6 pages • 2024
  • Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+ The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) bathrooms D: bathrooms Ref: 240.24(E) The MAXIMUM number of groun...
    (0)
  • $10.09
  • + learn more
Residential Electrician Exam #4 Questions And Answers
  • Residential Electrician Exam #4 Questions And Answers

  • Exam (elaborations) • 7 pages • 2024
  • Available in package deal
  • When a single branch-circuit with an equipment grounding conductor is supplying a detached garage from a house, what, if any, additional grounding electrode(s) is/are required at the garage? a) A ground rod and underground metal water pipe. b) A metal underground water pipe only. c) A metal underground water pipe and building steel, if available. d) No additional electrodes are required. - Answer-D: No additional electrodes are required. Ref: 250.32(A), Ex. The point of attachment of a se...
    (0)
  • $7.99
  • + learn more
Residential Electrician Exam #2 Questions and Answer 100% Accurate
  • Residential Electrician Exam #2 Questions and Answer 100% Accurate

  • Exam (elaborations) • 5 pages • 2024
  • Available in package deal
  • Residential Electrician Exam #2 Questions and Answer 100% AccurateResidential Electrician Exam #2 Questions and Answer 100% AccurateResidential Electrician Exam #2 Questions and Answer 100% Accurate The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches - ANSWER-C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed ...