Package deal
Residential Electrician Verified Bundle With Complete Questions And Answers
Residential Electrician Verified Bundle With Complete Questions And Answers
[Show more]Residential Electrician Verified Bundle With Complete Questions And Answers
[Show more]Hot or live wire - Ungrounded conductor 
Neutral wire - Grounded conductor 
Panel earth ground - Grounding electrode conductor 
Earth or ground wire - Equipment grounding conductor 
Grounding rod - Grounding Electrode 
Main disconnect - Service disconnect 
Main panel - Service or distribution electr...
Preview 3 out of 23 pages
Add to cartHot or live wire - Ungrounded conductor 
Neutral wire - Grounded conductor 
Panel earth ground - Grounding electrode conductor 
Earth or ground wire - Equipment grounding conductor 
Grounding rod - Grounding Electrode 
Main disconnect - Service disconnect 
Main panel - Service or distribution electr...
Which of that following locations at dwelling units require GFCI protection? - Answer-a. Receptacles 
within gaarages 
Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable 
diameter? - Answer-a. Type MC 
Which of the following circuits require a minimum of 20A ...
Preview 1 out of 4 pages
Add to cartWhich of that following locations at dwelling units require GFCI protection? - Answer-a. Receptacles 
within gaarages 
Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable 
diameter? - Answer-a. Type MC 
Which of the following circuits require a minimum of 20A ...
A(n) _______ is the circuit conductors between the final overcurrent device and the outlets. 
open circuit 
branch circuit 
feeder circuit 
service conductor - Answer-branch circuit 
The circuit conductors between the service equipment and the final branch circuit overcurrent 
protection device is a...
Preview 2 out of 14 pages
Add to cartA(n) _______ is the circuit conductors between the final overcurrent device and the outlets. 
open circuit 
branch circuit 
feeder circuit 
service conductor - Answer-branch circuit 
The circuit conductors between the service equipment and the final branch circuit overcurrent 
protection device is a...
The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop 
shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches - Answer-C: 20 inches 
Ref: 210.52(C)(5) 
For dwelling units, panelboards are permitted to be located in all the areas listed E...
Preview 2 out of 7 pages
Add to cartThe MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop 
shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches - Answer-C: 20 inches 
Ref: 210.52(C)(5) 
For dwelling units, panelboards are permitted to be located in all the areas listed E...
When a single branch-circuit with an equipment grounding conductor is supplying a detached garage 
from a house, what, if any, additional grounding electrode(s) is/are required at the garage? 
a) A ground rod and underground metal water pipe. 
b) A metal underground water pipe only. 
c) A metal unde...
Preview 2 out of 7 pages
Add to cartWhen a single branch-circuit with an equipment grounding conductor is supplying a detached garage 
from a house, what, if any, additional grounding electrode(s) is/are required at the garage? 
a) A ground rod and underground metal water pipe. 
b) A metal underground water pipe only. 
c) A metal unde...
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase 
underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG 
copper to 1 AWG copper is __ AWG copper 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - Answer-4...
Preview 2 out of 15 pages
Add to cartThe minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase 
underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG 
copper to 1 AWG copper is __ AWG copper 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - Answer-4...
Which of that following locations at dwelling units require GFCI protection? - Answer-Receptacles within 
gaarages 
Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable 
diameter? - Answer-Type MC 
Which of the following circuits require a minimum of 20A of ove...
Preview 1 out of 4 pages
Add to cartWhich of that following locations at dwelling units require GFCI protection? - Answer-Receptacles within 
gaarages 
Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable 
diameter? - Answer-Type MC 
Which of the following circuits require a minimum of 20A of ove...
What is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug connected 
dishwasher installed under a kitchen counter in a dwelling unit? 
a) 11⁄2 feet 
b) 2 feet 
c) 3 feet 
d) 4 feet - Answer-D: 4 feet 
Ref: 422.16(B)(2)(2) 
What is the MINIMUM size copper SE cable with type T...
Preview 2 out of 8 pages
Add to cartWhat is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug connected 
dishwasher installed under a kitchen counter in a dwelling unit? 
a) 11⁄2 feet 
b) 2 feet 
c) 3 feet 
d) 4 feet - Answer-D: 4 feet 
Ref: 422.16(B)(2)(2) 
What is the MINIMUM size copper SE cable with type T...
the NEC is the basic standard; local and state codes are to be considered also. - Answer-What code sets 
standards for electrical installation work? 
The local electrical inspection authority - Answer-what authority enforces the requirements set by the 
NEC? 
Minimum - Answer-does the NEC provide mi...
Preview 2 out of 7 pages
Add to cartthe NEC is the basic standard; local and state codes are to be considered also. - Answer-What code sets 
standards for electrical installation work? 
The local electrical inspection authority - Answer-what authority enforces the requirements set by the 
NEC? 
Minimum - Answer-does the NEC provide mi...
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - Answer-A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer...
Preview 2 out of 8 pages
Add to cartFerrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - Answer-A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.
No, you only buy these notes for $14.69. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
81531 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now