RESIDENTIAL WIREMAN ELECTRICAL EXAM REVIEWS
- Exam (elaborations) • 5 pages • 2024
-
- $9.99
- + learn more
RESIDENTIAL WIREMAN ELECTRICAL 
EXAM REVIEWS 
The minimum size equipment grounding conductor for a 100 
ampere, 120/240 volt single phase underground dwelling 
feeder whose ungrounded conductors have been increased in 
size from 3 AWG copper to 1 AWG copper is __ AWG copper 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - CORRECT 
ANSWER-4 
The continuity of the grounded conductor shall depend on a 
busbar or __ only. 
Continuity, Grounded conductors 
200.12 - CORRECT AN...
-
Fire Alarm TFM12 questions and answers well illustrated.
- Exam (elaborations) • 7 pages • 2023
- Available in package deal
-
- $10.49
- + learn more
Fire Alarm TFM12 questions and answers well illustrated. 
 
 
 
 
 
 
 
 
 
 
 
What does PLFA stand for? - correct answers.Power Limited Fire Alarm 
 
What does NPLFA stand for? - correct answers.Non Power Limited Fire Alarm 
 
What material must NPLFA circuit conductors be made from - correct answers.Only solid or stranded copper is permitted 
 
What is a single station detector? - correct answers.Battery powered smoke detectors that do not communicate off premises. 
 
What is a multiple stati...
-
Load Calculations Branch and Feeder Circuits Exam Questions and Complete Solutions.
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
Load Calculations Branch and Feeder Circuits Exam Questions and Complete Solutions 
 
maximum load that may be supplied by 20a, 120v circuit? - Ans: 20a x 120v = 2400va 
 
maximum load that may be supplied by 20a, 3 wire, 120/240v circuit? - Ans: 20a x 240v = 4800va 
 
maximum load that may be supplied by 20a, 208v 3 phase circuit? - Ans: 20a x 208v x 1.732 = 7205.12va 
 
minimum size circuit breaker required for 9 florescent ballast rated at 1.5a at 120v, as a continuous load? - Ans: determine ...
-
26401-20 - Load Calculations: Feeders and Services. Exam Questions With Correct Answers.
- Exam (elaborations) • 4 pages • 2024
-
- $10.49
- + learn more
©THEBRIGHTSTARS 2024 
26401-20 - Load Calculations: Feeders and 
Services. Exam Questions With 
Correct Answers. 
What NEC Article covers feeder circuits? - answerNEC Article 215 
The conductors and equipment for delivering electric energy from the serving utility to the 
wiring system of the premises served is a? - answerService 
The overhead conductors between the utility electric supply system and the service point is 
_____? - answerService drop 
What sections make up electrical Calculation...
-
	NEC Journeyman Test Prep graded A+ Latest 2022/2023
- Exam (elaborations) • 2 pages • 2022
-
- $9.99
- + learn more
For electrically operated in - sink waste disposers, what is the minimum and maximum length allowed for electrical cable? 
18 inches- 36 inches. 
422.16 (B)(1)(2) 
 
 
 
Rigid metal conduit must be securely fastened within how many feet of junction box? 
3 feet. 
344.30 (A) 
*See exceptions 
 
 
 
In a health care location where flammable anesthetics are employed, the entire area shall be considered to be a Class 1 Division 1 location that extends upward to a level of how many feet above the flo...