SPI
Liberty University
Page 3 out of 51 results
Sort by
-
SPI Davies, UT Physics, part 1 questions with complete solutions
- Exam (elaborations) • 4 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? 
A: Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. 
B: Prolong the sonogram to make videos of the fetus for each family member. 
C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. 
D: Maximize the acoustic output to brighten the overall image. 
E: Extend...
-
Davies SPI REVIEW print part 2| 500 questions| with complete solutions
- Exam (elaborations) • 62 pages • 2023
- Available in package deal
-
- $15.49
- + learn more
In order for distance measurements to be accurate in an ultrasound tissue phantom, the phantom sound propagation speed must be: 
A: 13 us/cm 
B: 1.54 m/s 
C: 154o m/s 
D: 1/2 the speed of sound in tissue 
E: Twice the speed of sound in soft tissue CORRECT ANSWERS: C: 1540 m/s 
 
You expanded the image sector width to improve visualization of a large mass. What can you do to maintain the same temporal resolution you had before your adjustment? 
A: Increase the digitization bit depth 
B: In...
-
DAVIES SPI: II. Physical Principles (20% of ARDMS)
- Exam (elaborations) • 31 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
You have increased the transmit power while performing a pelvic ultrasound examination. This action increases which of the following? 
 
A. Penetration 
B. Acoustic power 
C. Image brightness 
D. Voltage applied to the transducer elements 
E. All of the above CORRECT ANSWERS: E. All of the above 
 
Attenuation of the sound beam increases with increasing: 
 
A. Path length 
B. Absorption 
C. Frequency 
D. Scattering and reflection 
E. All of the above CORRECT ANSWERS: E. All of the above 
...
-
Davies SPI 153 questions with complete solutions
- Exam (elaborations) • 11 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
Interference patterns of reflected waves causes? CORRECT ANSWERS: acoustic speckle 
 
which of the following terms denotes the time it takes for one cycle to occur? CORRECT ANSWERS: Period 
 
which of the following increases as frequency increases? CORRECT ANSWERS: absorption 
scattering 
attenuation 
 
What is meant by the dead zone in performance testing? CORRECT ANSWERS: Distance from the transducer to the first identifiable echo. 
 
What sound-tissue interaction is necessary to form an u...
-
SPI Review Questions – Davies| 120 questions| with complete solutions
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
Will not cause a redirection of part of the ultrasound energy CORRECT ANSWERS: absorption 
 
You are scanning a large mass composed primarily of fat. What will you most likely encounter? CORRECT ANSWERS: axial misregistration of object distal to the mass on the screen due to the slower propagation speed through fat 
 
What 2 conditions must be present to cause a refraction in soundwave? CORRECT ANSWERS: oblique incidence and 
change in propagation speed 
 
What may be detected with refraction...
Want to regain your expenses?
-
Spi Davies Spi Davies| 618 questions| 172 pages| with complete solutions
- Exam (elaborations) • 172 pages • 2023
- Available in package deal
-
- $14.99
- + learn more
What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? 
 
A. Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. 
 
B. Prolong the sonogram to make videos of the fetus for each family member. 
 
C. Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. 
 
D. Maximum the acoustic output to brighten the overall image. 
 
E. E...
-
Davie's SPI Review| 304 questions| with complete solutions
- Exam (elaborations) • 21 pages • 2023
- Available in package deal
-
- $12.99
- + learn more
This converter converts the numbers stored in memory to proportional voltages that control the brightness on a CRT monitor CORRECT ANSWERS: Digital to Analog Converter 
 
The Digital Scan Converter is AKA: CORRECT ANSWERS: Image Memory 
 
This is where images are stored in the ultrasound system: CORRECT ANSWERS: Scan Converter 
 
The system component which is most responsible for transmit focusing: CORRECT ANSWERS: Beam Former 
 
The process of filling in the empty spaces between scan lines:...
-
DAVIES SPI REVIEW| 129 questions| with complete solutions
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
Which of the following helps to improve the elevation resolution to B- mode image? correct answers Focusing with and acoustic lens 
 
During and exam, you encounter all of the interactions of ultrasound and tissue listed. Which one will NOT cause redirection of part of the ultrasound energy? correct answers Absorption 
 
When you adjust the TGC component of the ultrasound system implements the changes? correct answers Receiver 
 
Which is NOT true about lateral resolution? correct an...
-
Davies SPI REVIEW| 1707 questions| 178 pages| verified answers
- Exam (elaborations) • 178 pages • 2023
- Available in package deal
-
- $16.99
- + learn more
What action below would be most in keeping with the ALARA principle while performing a diagnostic ultrasound examination? 
A: Allow multiple students to scan an obstetrical patient because the fetus is in a good position for imaging. 
B: Prolong the sonogram to make videos of the fetus for each family member. 
C: Complete the diagnostic scan in a timely fashion at the lowest output power that achieves a quality image. 
D: Maximize the acoustic output to brighten the overall image. 
E: Extend...
-
SPI Registry| 80 questions| with complete solutions
- Exam (elaborations) • 6 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
All numerical values should have corresponding _____. CORRECT ANSWERS: units 
 
An ______ tool can be used to measure area CORRECT ANSWERS: ellipse 
 
_________ is not a unit. CORRECT ANSWERS: Percent 
 
Giga CORRECT ANSWERS: billion 
10^9 
G 
 
micro CORRECT ANSWERS: millionth 
10^-6 
 
How many hertz is 3MHz? 
a. 3,000,000 
b. 3,000 
c. 333 
d. 0.003 CORRECT ANSWERS: 3,000,000 
 
How much bigger is a billion than a million? 
a. 10 times 
b. 100 times 
c. 1,000 times 
d. 500 times CORREC...
How much did you already spend on Stuvia? Imagine there are plenty more of you out there paying for study notes, but this time YOU are the seller. Ka-ching! Discover all about earning on Stuvia