EPA 608
Liberty University
Page 2 out of 45 results
Sort by
-
Epa 608 Universal Questions With Correct Answers
- Exam (elaborations) • 18 pages • 2023
- Available in package deal
-
- $14.49
- + learn more
Refrigeration technicians who violate the Clean Air Act can: - ans Lose their EPA certification, be fined, be required to appear in Federal court. 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - ans recovery and recycling. 
 
Refrigerant that is recovered can be returned to: - ans the same system or other systems owned by the same person without restriction. 
 
Refrigerant can not be called "reclaimed" unless it: - . ...
-
EPA Section 608 Technician Certification Study Guide questions with correct answers
- Exam (elaborations) • 34 pages • 2023
- Available in package deal
-
- $13.49
- + learn more
What are the typical uses of the center port of gauge set? ans Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? ans Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used on the gauges of a manifold gauge set? ans High side is 0 to 500 PSIG; Low side is 0 to 350 PSIG and 0 to 30 in. Hg below atmospheric pressure. 
 
Is the refrigerant leaving a condenser at a high or...
-
EPA Universal questions with correct answers
- Exam (elaborations) • 16 pages • 2023
- Available in package deal
-
- $12.99
- + learn more
Which refrigerants contain the most chlorine? ans CFC. 
R11,R12,R500. 
 
As of what date did it become unlawful to intentionally release Class I and Class II refrigerants to the atmosphere? ans July 1 1992. 
 
Which refrigerants have the lowest ozone depletion potential (ODP)? ans HFC. 
R134a. 
 
The molecule found in CFC and HCFC refrigerants that destroys ozone in the stratosphere is: ans Chlorine. 
 
Stratospheric ozone consists of: ans Three oxygen atoms. 
 
S...
-
EPA 608 study material including (Core, type 1, 2 and 3) questions with correct answers
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $10.49
- + learn more
a vacum pump should be connected ans as far away from the pump as possible 
 
a high capacity vacuum pump and short, large diameter hoses will ans dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
ozone contains three ans oxygen atoms 
 
one chlorine atom can destroy ans 100,000 ozone molecules 
 
CFC's do not dissolve in water and do not breakdown into other compounds that dissolve in water ans CFC's cannot be washed out of the lowe...
-
EPA Certification Exam questions with correct answers
- Exam (elaborations) • 12 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
Which Refrigerants contain the most chlorine? ans CFC's 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? ans July 1, 1992 
 
Which Refrigerants have the lowest zone depletion potential? ans HFC's 
 
The molecule found in CFC's and HCHC's refrigerants that destroys the ozone in the stratosphere is: ans Chlorine 
 
Stratospheric ozone consists of: ans Three oxygen atoms 
 
Stratospheric ozone de...
Fear of missing out? Then don’t!
-
EPA 608 Certification questions with correct answers
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $12.49
- + learn more
What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? ans November 14, 1994 
 
Section 608 of the Federal Clean Air Act requires technicians to what? ans Recover all refrigerants. 
 
The objective of the Clean Air Act is to protect what? ans The earth's stratosphere. 
 
HFC's ans HydroFlouroCarbon's 
 
CFC's ans ChloroFluoroCarbon's 
 
ODP ans Ozone Depletion Potential 
 
Which international treaty agreeme...
-
EPA 608 study material including (Core, type 1, 2 and 3) questions with complete solutions
- Exam (elaborations) • 5 pages • 2022
-
Available in package deal
-
- $7.49
- + learn more
a vacum pump should be connected correct answer: as far away from the pump as possible 
 
a high capacity vacuum pump and short, large diameter hoses will correct answer: dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
ozone contains three correct answer: oxygen atoms 
 
one chlorine atom can destroy correct answer: 100,000 ozone molecules 
 
CFC's do not dissolve in water and do not breakdown into other compounds that dissolve in water correct answer: CFC's ca...
-
Core Study Guide EPA 608| 182 questions| with complete solutions
- Exam (elaborations) • 11 pages • 2022
-
Available in package deal
-
- $8.49
- + learn more
What is the state of the refrigerant entering the metering device? correct answer: High pressure liquid 
 
What components are metering devices? correct answer: Thermostatic expansion valve and capillary tube 
 
What is the state of refrigerant entering the compressor? correct answer: Low Pressure Vapor 
 
What is the color of the low side gauge on the gauge manifold set? correct answer: Blue 
 
What can the compound gauge be used for? correct answer: Can only be used for low pressures and ...
-
EPA 608 Core practice test| 65 questions| with complete solutions
- Exam (elaborations) • 5 pages • 2022
-
Available in package deal
-
- $6.49
- + learn more
To process refrigerant to a level that is equal to new product specifications as correct answer: Reclaiming 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for correct answer: Leak testing 
 
Silicone elastomers are not compatible with what refrigerant correct answer: HFC 
 
How many molecules does an ozone molecule contain? correct answer: 3 oxygen atoms 
 
Recover any remaining refrigerant and then render the cylinder useless, ...
-
EPA 608 Core 2022| 59 questions| with complete solutions
- Exam (elaborations) • 5 pages • 2022
-
Available in package deal
-
- $6.49
- + learn more
One of the most important tools for a HVACR tech is the gauge manifold set correct answer: The left side, compound gauge (blue) and the right side, high-pressure gauge (red), are attached to the manifold to measure system pressures. Hoses are used to connect the manifold to the refrigeration system's access ports or service valves to gain access to system pressures. The compound gauge measures low-pressure (psig) and vacuum (inches Hg). 
 
The left side, compound gauge (blue) and the right si...
Do you wonder why so many students wear nice clothes, have money to spare and enjoy tons of free time? Well, they sell on Stuvia! Imagine your study notes being downloaded a dozen times for $15 each. Every. Single. Day. Discover all about earning on Stuvia