Required fire rating of demising partition between tenant spaces -Answer- 1-hour Required fire rating of partitions along a public corridor -Answer- 1-hour Thresholds, if provided at doorways, shall be ___inch high maximum. -Answer- 1/2 inch maximum Doors opening from occupied spaces into ...

[Show more]

Preview 2 out of 11  pages

  • October 18, 2024
  • 11
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • NCIDQ PRAC
  • NCIDQ PRAC
avatar-seller
PossibleA
NCIDQ PRAC EXAM



NCIDQ PRAC EXAM STUDY QUESTIONS
AND ANSWERS UPDATED 2024
Required fire rating of demising partition between tenant spaces -Answer- ✔1-hour

Required fire rating of partitions along a public corridor -Answer- ✔1-hour

Thresholds, if provided at doorways, shall be ___inch high maximum. -Answer- ✔1/2
inch maximum

Doors opening from occupied spaces into the path of egress travel shall not project
more than ___" into the required width -Answer- ✔7"

Where a pair of doors is provided, one of the doors MUST not be less than ____ wide. -
Answer- ✔36"

Door handles/pulls/ latches shall be ____inches minimum and _____inches maximum
above the finish floor -Answer- ✔34 inches minimum and 48 inches maximum

_____ doors shall swing in the direction of egress travel where serving a room or area
containing an occupant load of 50 or more persons. -Answer- ✔pivot or side-hinged
swinging doors

This type of fire separation is required between an Assembly Occupancy and a
Mercantile Occupancy -Answer- ✔2 hour fire separation

Partitions that demise an Assembly Occupancy of _____or greater must be 1-hr fire
rated -Answer- ✔750 sq. ft.

The means of egress must have a ceiling height not less than ____. -Answer- ✔7'-6"

Where must smoke and heat detectors be located? -Answer- ✔In all rooms, corridors,
and storage areas

Fire extinguishers MUST be located no more than ____feet from the furthest occupant.
-Answer- ✔75 feet

The minimum number of fire extinguishers MUST be calculated based on...? -Answer-
✔one fire extinguisher per 3,000 sq. ft.

An audio/ visual fire signal device must be visible from any location in the room or space
and must be mounted at...? -Answer- ✔between 6'-8" to 7'-6" AFF


NCIDQ PRAC EXAM

, NCIDQ PRAC EXAM



There MUST be an audio/ visual fire signal device located in....? -Answer- ✔in each
restroom, hallway, lobby, and general assembly area

Storage rooms exceeding _____sq ft must be 1-hour rated. -Answer- ✔100 sq ft

Glazing in fire rated partitions, doors, or sidelights may not exceed _____ sq. in. -
Answer- ✔240 sq. in.

All objects at a height of 27"-80" AFF must not protrude more than ___ into an egress
path of travel. -Answer- ✔4"

Protruding objects are permitted to extend below the minimum ceiling height provided a
minimum headroom of ___ shall be provided along the path of egress -Answer- ✔6'-8"

The travel distance must not exceed _____ measured along the path of travel -Answer-
✔250'-0"

Means of Egress: ALL paths of travel MUST be accessible and provide ___ at changes
of travel direction. -Answer- ✔at a minimum, 60" turning circle

Can a path of egress travel pass through a secondary space that is subject to closure
by doors or contains storage materials? -Answer- ✔NO

Means of egress: the common path of egress travel distance must not exceed _____. -
Answer- ✔MUST NOT exceed 100'-0"

Means of egress: how is travel distance to an exit measured? -Answer- ✔It must be
measured on the floor along the centerline of the natural path of travel, starting from the
most remote point to the centerline of the exit.

Height of doors must not be less than ____. -Answer- ✔7 feet

All door openings shall be a minimum of ____ wide. -Answer- ✔minimum 36" wide

Where a power door operator is provided, it shall be installed on ______ so as to allow
persons to activate the opening of the door from either side. -Answer- ✔It shall be
installed on the latch side

Where can you find requirements for power door operations controls? -Answer-
✔Egress 4.5.4




NCIDQ PRAC EXAM

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller PossibleA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.89. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81311 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.89
  • (0)
  Add to cart