100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
PACKAGE DEAL OF NERC QUESTION AND ANSWERS RATED A+ 2023 $38.49   Add to cart

Package deal

PACKAGE DEAL OF NERC QUESTION AND ANSWERS RATED A+ 2023

NERC ~ RC (NP3 Transmission) Question and answers correctly solved 2023 Exam (elaborations) NERC Terms Question and answers 2023 verified to pass Exam (elaborations) NERC CIP STANDARDS Question and answers already passed 2023 Exam (elaborations) NERC book quiz questions and answers already pa...

[Show more]
20 items

NERC Reliability Coordinator Exam Vocabulary 2023 Questions with complete solution

(0)
$19.49

NERC Reliability Coordinator Exam Vocabulary 2023 Questions with complete solution Accelerating Power - correct answer In a GENERATOR, the difference between the MECHANICAL INPUT POWER and the electrical output POWER (assuming no LOSSES). For a GENERATOR's TORQUE ANGLE to change, the GENERAT...

View example

KNOWN NERC EXAM QUESTIONS: From Class and answers rated A+ 2023

(0)
$12.49

KNOWN NERC EXAM QUESTIONS: From Class and answers rated A+ 2023 A Balancing Authority notices that Operating Reserve has steadily declined throughout the hour. What is the most likely cause? a) Loss of a large generator in the area b) An inaccurate load forecast c) Loss of a major transmissi...

View example

NERC RC Exam Question and answers 100% correct 2023

(0)
$12.49

NERC RC Exam Question and answers 100% correct 2023 Common standard time period for station battery to handle outage of AC power to chargers - correct answer 8-12 hours Time to restore data exchange redundancy when redundancy testing by RC/TOP/BA deemed unsuccessful - correct answer 2 h...

View example

NERC Certification Practice Questions and answers 100% correct 2023

(0)
$10.99

NERC Certification Practice Questions and answers 100% correct 2023 Which of the following represents a virtual tie-line updated in real time? - correct answer pseudo-tie Balancing Areas shall analyze forecasted generation availability and reserve levels, and inform their reliability coordi...

View example

SOS NERC Prep - Reliability Exam Question and answers already passed 2023

(0)
$16.99

SOS NERC Prep - Reliability Exam Question and answers already passed 2023 The Reliability Coordinator just informed you of a slow time error correction which will begin at the top of the next hour. Your EMS system will not let you change your scheduled frequency. Your Frequency Bias Setting is -1...

View example

Nerc Test Question and answers already passed 2023

(0)
$12.99

Nerc Test Question and answers already passed 2023 According to Nerc Standards, an emergency interchange transaction can be exempt from tagging if it is less than_________________ - correct answer 60 minutes A BA or LSE that requests an EEA 3 must complete and EEA 3 report and submit it to ...

View example

Practice Test NERC Questions and answers correctly solved 2023

(0)
$16.49

A transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? - correct answer The phase angle will increase. When load is increased ...

View example

BNER BNERC EXAM PREPARATION Question and answers already pass 2023 AAL DOES NOT APPLY - correct answer According to BAAL requirements of BAL-001, which of the following statements is true when actual frequency is greater than Scheduled Frequency? Tie

(0)
$13.49

BNERC EXAM PREPARATION Question and answers already pass 2023 AAL DOES NOT APPLY - correct answer According to BAAL requirements of BAL-001, which of the following statements is true when actual frequency is greater than Scheduled Frequency? Tie Lines - correct answer The ACE equation must...

View example

BNERC EXAM PREPARATION Question and answers already pass 2023

(0)
$12.49

BNERC EXAM PREPARATION Question and answers already pass 2023 AAL DOES NOT APPLY - correct answer According to BAAL requirements of BAL-001, which of the following statements is true when actual frequency is greater than Scheduled Frequency? Tie Lines - correct answer The ACE equation must...

View example

NERC Transmission Practice Test Questions with complete solution 2023

(0)
$12.49

NERC Transmission Practice Test Questions with complete solution 2023 Which type of relay operates on the premise of comparing the flow in and out of the area of protection? - correct answer Differential relay Underfrequency load shedding is set-up so that which of the following does NOT oc...

View example

NERC text questions and answer rated A+ 2023

(0)
$15.49

NERC text questions and answer rated A+ 2023 Operating reserve may be provided by which of the following? A. LTCs B. Capacitor banks C. Voltage regulators D. Interruptible loads D. Interruptible loads Which of the following is the responsibility of a reserve sharing group (RSG)? A. Complyi...

View example

NERC Reliability Standards Question and answers 100% correct 2023

(0)
$12.49

NERC Reliability Standards Question and answers 100% correct 2023 BAL-001-0.1a Real Power Balancing Control Performance BAL-STD-002-0 Operating Reserves (WECC) BAL-003-0.1b Frequency Response and Bias BAL-004-0 Time Error Correction BAL-004-WECC-01 Automatic Time Error Correction BAL-00...

View example

NERC cheat sheet Question and answers already passed 2023

(0)
$12.49

NERC cheat sheet Question and answers already passed 2023 3 phase power equation - correct answer √3 x V x I x Power factor Total power equation - correct answer S = √3 x V x I Generator rpm equation - correct answer N = 120xF/P Droop Equation - correct answer Generator C...

View example

SOS NERC Prep - RElIABILITY Exam Question and answers 2023 verified to pass

(0)
$18.49

SOS NERC Prep - RElIABILITY Exam Question and answers 2023 verified to pass A) Increase Net Interchange Schedule by 20 MWs. - correct answer The Reliability Coordinator just informed you of a slow time error correction which will begin at the top of the next hour. Your EMS system will not let ...

View example

NERC Practice Set 3 Questions with complete solution 2023

(0)
$11.99

NERC Practice Set 3 Questions with complete solution 2023 b. Perform power flow study in preparation of opening Line 1 - correct answer Your system is experiencing heavy loading and low voltage . What is the first response for a System Operator ? a) Take lines out of service b) Put ca...

View example

NERC Standards Question and answers 100% correct 2023

(0)
$14.49

NERC Standards Question and answers 100% correct 2023 How Many Active Standards are in BAL (Resource and Demand Balancing) - correct answer There are 8 Active Standards Listed Below: BAL-001-2 Real Power Balancing Control Performance Related Information Subject to Enforcement BAL-001-TRE-1 ...

View example

NERC book quiz questions and answers already passed 2023

(0)
$12.49

NERC book quiz questions and answers already passed 2023 You are an external BA with a frequency bais of 20 MW/.1 Hz that sees a frequency of 60.02 due to a large loss of load in the contingent BA. If your generator governor control systems responded to the frequency deviation approximately how m...

View example

NERC CIP STANDARDS Question and answers already passed 2023

(0)
$11.49

NERC CIP STANDARDS Question and answers already passed 2023 CIP 2 Identifying BES Cyber Systems - correct answer ...IBESCS CIP 3 Cyber Security Policy for BES Cyber Systems - correct answer ...CSPFBESCS CIP 4 Access Authorization Procedure - correct answer ...AAP CIP 4 CIP Excep...

View example

NERC Terms Question and answers 2023 verified to pass

(0)
$12.99

NERC Terms Question and answers 2023 verified to pass EEA 1 (Energy Emergency Alert) - correct answer EEA 2 (Energy Emergency Alert) - correct answer EEA 3 (Energy Emergency Alert) - correct answer DCS (Distributed Control Standard) - correct answer A Balancing Authority i...

View example

NERC ~ RC (NP3 Transmission) Question and answers correctly solved 2023

(0)
$13.99

NERC ~ RC (NP3 Transmission) Question and answers correctly solved 2023 Q32618 When a high voltage transmission line circuit breaker trips open as a result of a fault, a synchronous check relay will monitor certain values on both the line side and the bus side of the open circuit breaker. Before ...

View example
Show all
avatar-seller

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Academia199. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $38.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67163 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$276.80 $38.49
  • (0)
  Add to cart