EPA 608 Core Questions with correct answers
all of the above Correct Answer - Refrigeration technicians who violate the clean air act can: 
A. lose their epa certification 
B. be fined. 
C. be required to appear in federal court 
D. all of the above 
 
november 1995 Correct Answer - It has been illegal to vent substitutes for CFC and HCFC refrigerants since: 
 
R22 Correct Answer - which refrigerant has the lowest odp? 
R22, R11, R12, R113 
 
recover Correct Answer - to remove refrigerant in any condition from a system and store it in an...
- Exam (elaborations)
- • 13 pages •
all of the above Correct Answer - Refrigeration technicians who violate the clean air act can: 
A. lose their epa certification 
B. be fined. 
C. be required to appear in federal court 
D. all of the above 
 
november 1995 Correct Answer - It has been illegal to vent substitutes for CFC and HCFC refrigerants since: 
 
R22 Correct Answer - which refrigerant has the lowest odp? 
R22, R11, R12, R113 
 
recover Correct Answer - to remove refrigerant in any condition from a system and store it in an...
EPA 608 9th edition Questions with correct answers
Reusable refrigerant containers under high-pressure must be hydrostatically tested how often? Correct Answer - 5 years 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? Correct Answer - $44,539 
 
HCFCs contain Correct Answer - Hydrogen, Chlorine, Fluorine, and Carbon 
 
Which of the following refrigerants is an HFO? Correct Answer - R-1234ze 
 
An ozone molecule contains; Correct Answer - Three oxygen atoms 
 
...
- Exam (elaborations)
- • 13 pages •
Reusable refrigerant containers under high-pressure must be hydrostatically tested how often? Correct Answer - 5 years 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? Correct Answer - $44,539 
 
HCFCs contain Correct Answer - Hydrogen, Chlorine, Fluorine, and Carbon 
 
Which of the following refrigerants is an HFO? Correct Answer - R-1234ze 
 
An ozone molecule contains; Correct Answer - Three oxygen atoms 
 
...
EPA 608 (TYPE II) Exam
When a new system has been assembled, the first thing to do is? Correct Answer - Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? Correct Answer - Pressurized with nitrogen then leak checked. 
 
The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds _________ of t...
- Exam (elaborations)
- • 9 pages •
When a new system has been assembled, the first thing to do is? Correct Answer - Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? Correct Answer - Pressurized with nitrogen then leak checked. 
 
The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds _________ of t...
EPA Section 608 Technician Certification Study Guide Questions with correct answers
What are the typical uses of the center port of gauge set? Correct Answer - Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? Correct Answer - Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used on the gauges of a manifold gauge set? Correct Answer - High side is 0 to 500 PSIG; Low side is 0 to 350 PSIG and 0 to 30 in. Hg below atmospheric pressure. 
 
Is the refrigerant leaving a c...
- Exam (elaborations)
- • 34 pages •
What are the typical uses of the center port of gauge set? Correct Answer - Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? Correct Answer - Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used on the gauges of a manifold gauge set? Correct Answer - High side is 0 to 500 PSIG; Low side is 0 to 350 PSIG and 0 to 30 in. Hg below atmospheric pressure. 
 
Is the refrigerant leaving a c...
EPA 608 Type 3 Questions with correct answers
On low pressure chillers, moisture typically enters the refrigerant system through Correct Answer - air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: Correct Answer - 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller Correct Answer - ... 
 
A hydrostatic tube test kit is used to: Correct Answer - determine if a tube leaks 
 
Commercial and industrial process refrigera...
- Exam (elaborations)
- • 17 pages •
On low pressure chillers, moisture typically enters the refrigerant system through Correct Answer - air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: Correct Answer - 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller Correct Answer - ... 
 
A hydrostatic tube test kit is used to: Correct Answer - determine if a tube leaks 
 
Commercial and industrial process refrigera...
UPwith DATED EPA 608 QUIZLET (2023) Questions with correct answers
the state of the refrigerant entering the metering device is? Correct Answer - A subcooled high pressure liquid. 
 
what type of refrigerant is used in VERY high-pressure appliances? Correct Answer - R-503 
 
what type of refrigerant is used in MEDIUM pressure appliances? Correct Answer - R-500 
 
what type of refrigerant is used in HIGH pressure appliances? Correct Answer - R-410A and R-22 
 
what device is located at the END of the liquid line? Correct Answer - The expansion device. 
 
what ty...
- Exam (elaborations)
- • 18 pages •
the state of the refrigerant entering the metering device is? Correct Answer - A subcooled high pressure liquid. 
 
what type of refrigerant is used in VERY high-pressure appliances? Correct Answer - R-503 
 
what type of refrigerant is used in MEDIUM pressure appliances? Correct Answer - R-500 
 
what type of refrigerant is used in HIGH pressure appliances? Correct Answer - R-410A and R-22 
 
what device is located at the END of the liquid line? Correct Answer - The expansion device. 
 
what ty...
EPA Certification Exam Questions with correct answers
Which Refrigerants contain the most chlorine? Correct Answer - CFC's 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? Correct Answer - July 1, 1992 
 
Which Refrigerants have the lowest zone depletion potential? Correct Answer - HFC's 
 
The molecule found in CFC's and HCHC's refrigerants that destroys the ozone in the stratosphere is: Correct Answer - Chlorine 
 
Stratospheric ozone consists of: Correct Answer - Three oxy...
- Exam (elaborations)
- • 13 pages •
Which Refrigerants contain the most chlorine? Correct Answer - CFC's 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? Correct Answer - July 1, 1992 
 
Which Refrigerants have the lowest zone depletion potential? Correct Answer - HFC's 
 
The molecule found in CFC's and HCHC's refrigerants that destroys the ozone in the stratosphere is: Correct Answer - Chlorine 
 
Stratospheric ozone consists of: Correct Answer - Three oxy...
HVAC: EPA 608 Certification Study Guide Questions with correct answers
Are there drop-in replacements for R-12 systems? Why or why not? Correct Answer - No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
What type of oil is used in R-134a and what oils will it mix with? Correct Answer - Ester based oils and they do not mix with other oils 
 
What type of lubricant is used with HCFCs? Correct Answer - Alkylbenzene lubricant 
 
What is difference b/w ternary blend a azeotropic blend? Correct Answer - Ternary blends ...
- Exam (elaborations)
- • 14 pages •
Are there drop-in replacements for R-12 systems? Why or why not? Correct Answer - No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
What type of oil is used in R-134a and what oils will it mix with? Correct Answer - Ester based oils and they do not mix with other oils 
 
What type of lubricant is used with HCFCs? Correct Answer - Alkylbenzene lubricant 
 
What is difference b/w ternary blend a azeotropic blend? Correct Answer - Ternary blends ...
EPA 608 study material including (Core, type 1, 2 and 3) Questions with correct answers
a vacum pump should be connected Correct Answer - as far away from the pump as possible 
 
a high capacity vacuum pump and short, large diameter hoses will Correct Answer - dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
ozone contains three Correct Answer - oxygen atoms 
 
one chlorine atom can destroy Correct Answer - 100,000 ozone molecules 
 
CFC's do not dissolve in water and do not breakdown into other compounds that dissolve in water Correct Answer - CFC...
- Exam (elaborations)
- • 9 pages •
a vacum pump should be connected Correct Answer - as far away from the pump as possible 
 
a high capacity vacuum pump and short, large diameter hoses will Correct Answer - dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
ozone contains three Correct Answer - oxygen atoms 
 
one chlorine atom can destroy Correct Answer - 100,000 ozone molecules 
 
CFC's do not dissolve in water and do not breakdown into other compounds that dissolve in water Correct Answer - CFC...
EPA 608 Certification Questions with correct answers
What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? Correct Answer - November 14, 1994 
 
Section 608 of the Federal Clean Air Act requires technicians to what? Correct Answer - Recover all refrigerants. 
 
The objective of the Clean Air Act is to protect what? Correct Answer - The earth's stratosphere. 
 
HFC's Correct Answer - HydroFlouroCarbon's 
 
CFC's Correct Answer - ChloroFluoroCarbon's 
 
ODP Correct Answer - Ozone Depletion Poten...
- Exam (elaborations)
- • 9 pages •
What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? Correct Answer - November 14, 1994 
 
Section 608 of the Federal Clean Air Act requires technicians to what? Correct Answer - Recover all refrigerants. 
 
The objective of the Clean Air Act is to protect what? Correct Answer - The earth's stratosphere. 
 
HFC's Correct Answer - HydroFlouroCarbon's 
 
CFC's Correct Answer - ChloroFluoroCarbon's 
 
ODP Correct Answer - Ozone Depletion Poten...