Papersbysue
Hello there? Welcome to my store here you are guaranteed high Quality past and recent study materials tailor made to make your study time at your institution easy and seamless. They are all GRADED A+ .ARE YOUR EXAMS DUE???you will get every study material here. You are WELCOME AND FEEL FREE TO REACH OUT TO ME FOR ASSISTANCE .
- 236
- 0
- 9
Community
- Followers
- Following
245 items
EPA 608 Book Exam TYPE III CERTIFICATION CORRECT 100%
Technicians maintaining, servicing, repairing or disposing of low-pressure appliances must be certified as - ANSWER Type III Technician or a Universal Technician. 
 
As of November 14, 1994, the sale of CFC and HCFC refrigerants is restricted to - ANSWER Certified technicians, NOTE: If EPA regulations change after the technician is certified, it will be the technician's responsibility to comply with any future changes. 
 
Because a low-pressure system operates below atmospheric pressure (in a v...
- Package deal
- Exam (elaborations)
- • 4 pages •
Technicians maintaining, servicing, repairing or disposing of low-pressure appliances must be certified as - ANSWER Type III Technician or a Universal Technician. 
 
As of November 14, 1994, the sale of CFC and HCFC refrigerants is restricted to - ANSWER Certified technicians, NOTE: If EPA regulations change after the technician is certified, it will be the technician's responsibility to comply with any future changes. 
 
Because a low-pressure system operates below atmospheric pressure (in a v...
EPA 608 Type III Correct Questions & Answers 2023-2024
Identify the pressure corresponding to 32 degrees F for R-123: ________. 
 
a) 23 inches of Hg vacuum 
b) 20 inches of Hg vacuum 
c) 17 inches of Hg vacuum 
d) 11 inches of Hg vacuum - ANSWER b) 20 inches of Hg vacuum 
 
A hydrostatic tube test kit is used to: _________. 
 
a) blow all water from the tubes 
b) remove any water from the machine 
c) vent refrigerant 
d) determine if a tube leaks - ANSWER d) determine if a tube leaks 
 
Excessive running of a purge system on a low pressure chiller ...
- Package deal
- Exam (elaborations)
- • 18 pages •
Identify the pressure corresponding to 32 degrees F for R-123: ________. 
 
a) 23 inches of Hg vacuum 
b) 20 inches of Hg vacuum 
c) 17 inches of Hg vacuum 
d) 11 inches of Hg vacuum - ANSWER b) 20 inches of Hg vacuum 
 
A hydrostatic tube test kit is used to: _________. 
 
a) blow all water from the tubes 
b) remove any water from the machine 
c) vent refrigerant 
d) determine if a tube leaks - ANSWER d) determine if a tube leaks 
 
Excessive running of a purge system on a low pressure chiller ...
EPA 608 Type III Study Guide Correct 100% Accurate(2023-2024 Latest Update)
The state of the refrigerant entering the metering device is: - ANSWER High pressure liquid 
 
The following components are metering devices: - ANSWER Evaporator pressure regulator, Thermostatic expansion valve 
 
The state of the refrigerant entering the compressor is: - ANSWER Low pressure vapor 
 
Before the recovery process can be initiated, a technician must know: - ANSWER The type of refrigerant in the system 
 
Checking the pressure of a recovery cylinder at a known temperature can determ...
- Package deal
- Exam (elaborations)
- • 5 pages •
The state of the refrigerant entering the metering device is: - ANSWER High pressure liquid 
 
The following components are metering devices: - ANSWER Evaporator pressure regulator, Thermostatic expansion valve 
 
The state of the refrigerant entering the compressor is: - ANSWER Low pressure vapor 
 
Before the recovery process can be initiated, a technician must know: - ANSWER The type of refrigerant in the system 
 
Checking the pressure of a recovery cylinder at a known temperature can determ...
EPA 608 Type 3 Certifications Questions & Answers
When using recovery or recycling equipment manufactured or imported on or after Nov 15, 1993, the required level of evacuation for low pressure equipment is _____ Hg absolute: 
 
30mm 
25mm 
15mm 
20mm - ANSWER 25mm 
 
The EPA requires that all commercial and industrial process refrigeration systems with more than 50lb of refrigerant be repaired when the annual leak rate exceeds ______: 
 
35% 
15% 
30% 
25% - ANSWER 35% 
 
Open-drive compressors are typically _____ compressors 
 
centrifugal 
r...
- Package deal
- Exam (elaborations)
- • 16 pages •
When using recovery or recycling equipment manufactured or imported on or after Nov 15, 1993, the required level of evacuation for low pressure equipment is _____ Hg absolute: 
 
30mm 
25mm 
15mm 
20mm - ANSWER 25mm 
 
The EPA requires that all commercial and industrial process refrigeration systems with more than 50lb of refrigerant be repaired when the annual leak rate exceeds ______: 
 
35% 
15% 
30% 
25% - ANSWER 35% 
 
Open-drive compressors are typically _____ compressors 
 
centrifugal 
r...
EPA 608 Type III Practice Questions & Answer
what is the primary water source for a recovery unit condensing coil? - ANSWER local municipal water supply 
 
approximately how much refrigerant vapor is left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed? - ANSWER 100 lbs 
 
a rupture disc on a recovery vessel for low pressure refrigerant relieves at ____ - ANSWER 15 psig 
 
on a centrifugal system, the purge unit takes its suction from the ____ - ANSWER top of the condenser 
 
a centrifugal ch...
- Package deal
- Exam (elaborations)
- • 3 pages •
what is the primary water source for a recovery unit condensing coil? - ANSWER local municipal water supply 
 
approximately how much refrigerant vapor is left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed? - ANSWER 100 lbs 
 
a rupture disc on a recovery vessel for low pressure refrigerant relieves at ____ - ANSWER 15 psig 
 
on a centrifugal system, the purge unit takes its suction from the ____ - ANSWER top of the condenser 
 
a centrifugal ch...
EPA 608 Practice exam Type 3| 50 Questions | Correct 100%
The maximum test pressure for leak testing a low-pressure centrifugal chiller is - ANSWER 10 psig 
 
Excessive operation of a purge system means - ANSWER The system has a leak on the sub-ambient pressure side of the system 
 
For a commercial refrigeration system with a charge of 50 pounds or more refrigerant, a substantial (or threshold) week rate will be reduced to ________ after January 1, 2019. - ANSWER 20% 
 
For a comfort cooling system with a charge of 50 pounds or more of refrigerant, a ...
- Package deal
- Exam (elaborations)
- • 4 pages •
The maximum test pressure for leak testing a low-pressure centrifugal chiller is - ANSWER 10 psig 
 
Excessive operation of a purge system means - ANSWER The system has a leak on the sub-ambient pressure side of the system 
 
For a commercial refrigeration system with a charge of 50 pounds or more refrigerant, a substantial (or threshold) week rate will be reduced to ________ after January 1, 2019. - ANSWER 20% 
 
For a comfort cooling system with a charge of 50 pounds or more of refrigerant, a ...
EPA 608 Type III Sample Test Questions & Answers
Where do leaks commonly occur in low pressure systems? 
a. Evaporator 
b. Condenser 
c. Purge unit 
d. Gaskets or fittings - ANSWER d. Gaskets or fittings 
 
Where do leaks commonly occur in open-drive type compressor systems? 
a. Evaporator 
b. Condenser 
c. Shaft seal 
d. Cooling tower - ANSWER c. Shaft seal 
 
Does refrigerant go out of the system in low pressure systems or does air and 
moisture go in? 
a. Refrigerant escapes through low pressure leaks. 
b. Air and moisture enter the refrige...
- Package deal
- Exam (elaborations)
- • 9 pages •
Where do leaks commonly occur in low pressure systems? 
a. Evaporator 
b. Condenser 
c. Purge unit 
d. Gaskets or fittings - ANSWER d. Gaskets or fittings 
 
Where do leaks commonly occur in open-drive type compressor systems? 
a. Evaporator 
b. Condenser 
c. Shaft seal 
d. Cooling tower - ANSWER c. Shaft seal 
 
Does refrigerant go out of the system in low pressure systems or does air and 
moisture go in? 
a. Refrigerant escapes through low pressure leaks. 
b. Air and moisture enter the refrige...
EPA 608 Type 3 Correct Questions & Answers
On low pressure chillers, moisture typically enters the refrigerant system through - ANSWER air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ANSWER 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ANSWER ... 
 
A hydrostatic tube test kit is used to: - ANSWER determine if a tube leaks 
 
Commercial and industrial process refrigeration systems must be repaired wh...
- Package deal
- Exam (elaborations)
- • 10 pages •
On low pressure chillers, moisture typically enters the refrigerant system through - ANSWER air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ANSWER 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ANSWER ... 
 
A hydrostatic tube test kit is used to: - ANSWER determine if a tube leaks 
 
Commercial and industrial process refrigeration systems must be repaired wh...
EPA 608 Type III Complete Questions & Answers
What do R-11 and R-123 refrigerants have in common? 
 
A. They are oxygen depleting 
B. They are Class I and II substances as defined by the EPA 
C. Both A and B 
D. Neither A nor B - ANSWER C. Both A and B 
 
What is the required evacuation level for recovering refrigerant from a low-pressure appliance with a recovery machine manufactured before November 15, 1993? 
 
A. 0 psig 
B. 4" Hg 
C. 10 A Hg 
D. 25" Hg - ANSWER D. 25" Hg 
 
How is frost best removed from a sight glass? 
 
A. reverse ...
- Package deal
- Exam (elaborations)
- • 11 pages •
What do R-11 and R-123 refrigerants have in common? 
 
A. They are oxygen depleting 
B. They are Class I and II substances as defined by the EPA 
C. Both A and B 
D. Neither A nor B - ANSWER C. Both A and B 
 
What is the required evacuation level for recovering refrigerant from a low-pressure appliance with a recovery machine manufactured before November 15, 1993? 
 
A. 0 psig 
B. 4" Hg 
C. 10 A Hg 
D. 25" Hg - ANSWER D. 25" Hg 
 
How is frost best removed from a sight glass? 
 
A. reverse ...
PACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correct
PACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Dire
- Package deal
- • 9 items •
- Funeral directing final exam Correct Questions & Solutions!! • Exam (elaborations)
- Funeral Directing Final Exam Prep 100% correct • Exam (elaborations)
- Funeral Directing Final Exam Review 100%correct • Exam (elaborations)
- Funeral Directing 1 Final Exam 100% accurate • Exam (elaborations)
- Funeral Directing final exam review 100%accurate • Exam (elaborations)
- And more ….
PACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Directing Final Exam Prep 100% correctPACKAGE DEAL FOR :Funeral Dire