Classrep2
On this page, you find all documents, package deals, and flashcards offered by seller ClassRep2.
- 1981
- 0
- 89
Community
- Followers
- Following
3 Reviews received
2070 items
SCSC 205 exam 2 CORRECT 100%
What are the components of a typical ideal soil? - ANSWER-Organic 5% 
-Air 25% 
-Water 25% 
-Mineral 45% 
 
There are 6 soil functions. List 4 of them. - ANSWER-Medium for plant growth 
-Recycling system for nutrients and organic wastes 
-Modifier of the Atmosphere 
-Habitat for soil organisms 
-System for water supply and purification 
-Engineering medium 
 
There are 14 essential macro and micronutrients. Name 10 and 
their elemental symbols. - ANSWER-Macro nutrients -Micronutrients 
(N)Nitrog...
- Exam (elaborations)
- • 3 pages •
What are the components of a typical ideal soil? - ANSWER-Organic 5% 
-Air 25% 
-Water 25% 
-Mineral 45% 
 
There are 6 soil functions. List 4 of them. - ANSWER-Medium for plant growth 
-Recycling system for nutrients and organic wastes 
-Modifier of the Atmosphere 
-Habitat for soil organisms 
-System for water supply and purification 
-Engineering medium 
 
There are 14 essential macro and micronutrients. Name 10 and 
their elemental symbols. - ANSWER-Macro nutrients -Micronutrients 
(N)Nitrog...
NATE AC EXAM BUNDLE 2024!!
NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM
- Package deal
- • 11 items •
- NATE AC Service Certification Correct 100% • Exam (elaborations)
- NATE Air Conditioning Installation & Service Practice Questions With Complete Solutions!! • Exam (elaborations)
- NATE A/C Exam #1 Questions & Answers(RTED A+) • Exam (elaborations)
- NATE AC Service Certification Questions & Answers(RATED A+) • Exam (elaborations)
- NATE: Air Conditioning Components CORRECT 100% • Exam (elaborations)
- And more ….
NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM BUNDLE 2024!!NATE AC EXAM
NATE A/C Exam #2 CORRECT 100%
The Fahrenheit scale is based on boiling water at sea level at what temperature? 
 
 A: 459 degrees 
 
 B: 212 degrees 
 
 C: 180 degrees 
 
 D: 100 degrees - ANSWERB: 212 degrees 
 
Zero pounds gauge corresponds on the absolute scale to: 
 
 A: 144 
 
 B: 212 
 
 C: 14.7 
 
 D: zero - ANSWERC: 14.7 
 
Hidden heat in refrigeration work is referred to as: 
 
 A: Intensity of heat 
 
 B: Latent heat 
 
 C: Heat a thermometer can "sense" 
 
 D: Cold - ANSWERB: Latent heat 
 
Absol...
- Package deal
- Exam (elaborations)
- • 17 pages •
The Fahrenheit scale is based on boiling water at sea level at what temperature? 
 
 A: 459 degrees 
 
 B: 212 degrees 
 
 C: 180 degrees 
 
 D: 100 degrees - ANSWERB: 212 degrees 
 
Zero pounds gauge corresponds on the absolute scale to: 
 
 A: 144 
 
 B: 212 
 
 C: 14.7 
 
 D: zero - ANSWERC: 14.7 
 
Hidden heat in refrigeration work is referred to as: 
 
 A: Intensity of heat 
 
 B: Latent heat 
 
 C: Heat a thermometer can "sense" 
 
 D: Cold - ANSWERB: Latent heat 
 
Absol...
NATE: Air Conditioning Troubleshooting CORRECT 100%
What are the symptoms of a TXV air conditioning system if it has lost its charge: - ANSWERThe superheat will increase and the low-side pressure will decrease 
 
A customer who owns a split air conditioning system complains that his system has been running but his house doesn't seem to be cooling properly. When the service technician arrives on the job, he or she finds that the indoor blower is operating and the air filter is clean. The condenser fan on the outdoor unit is operating, but he or...
- Package deal
- Exam (elaborations)
- • 9 pages •
What are the symptoms of a TXV air conditioning system if it has lost its charge: - ANSWERThe superheat will increase and the low-side pressure will decrease 
 
A customer who owns a split air conditioning system complains that his system has been running but his house doesn't seem to be cooling properly. When the service technician arrives on the job, he or she finds that the indoor blower is operating and the air filter is clean. The condenser fan on the outdoor unit is operating, but he or...
NATE AC Practice 3 Questions & Answers(RATED A+)
During an annual service check up, it is discovered that there is a moderate amount of resistance on a "bellyband" crankcase heater. What does this condition indicate? 
 
A. the crankcase heater will operate 
B. the crankcase heater will not operate 
C. the crankcase heater is open 
D. the crankcase heater voltage must be increased for proper operation - ANSWERA. the crankcase heater will operate 
 
High superheat is a symptom of: 
 
A. a system overcharge 
B. a clogged air filter 
C. a bl...
- Package deal
- Exam (elaborations)
- • 17 pages •
During an annual service check up, it is discovered that there is a moderate amount of resistance on a "bellyband" crankcase heater. What does this condition indicate? 
 
A. the crankcase heater will operate 
B. the crankcase heater will not operate 
C. the crankcase heater is open 
D. the crankcase heater voltage must be increased for proper operation - ANSWERA. the crankcase heater will operate 
 
High superheat is a symptom of: 
 
A. a system overcharge 
B. a clogged air filter 
C. a bl...
nate ac service test CORRECT 100%
A technician has determined a supply in a flexible duct system is leaking. What should be checked? - ANSWERAll connections inner and outer layers. 
 
Electronic air cleaners can operate with internal voltages as high as? - ANSWER5000v 
 
Why do some electromechanical type thermostats require connections to both the hot side and common side of the low voltage transfromer - ANSWERDisplay lights must be powered using both sides of the line 
 
the continuity reading on a functional fuse will be - AN...
- Package deal
- Exam (elaborations)
- • 8 pages •
A technician has determined a supply in a flexible duct system is leaking. What should be checked? - ANSWERAll connections inner and outer layers. 
 
Electronic air cleaners can operate with internal voltages as high as? - ANSWER5000v 
 
Why do some electromechanical type thermostats require connections to both the hot side and common side of the low voltage transfromer - ANSWERDisplay lights must be powered using both sides of the line 
 
the continuity reading on a functional fuse will be - AN...
NATE Core Exam Practice Questions 100% Answered!!
Ch. 1-1 The ability to utilize all types of communication skills is ________ to the HVACR technician. 
a) not as important as "hands-on" technical skills 
b) somewhat important 
c) unimportant 
d) very important - ANSWERd) very important 
 
Ch. 1-2 It is important to be _______ in filling out service orders so that office staff, other technicians, and customers will know what work you completed on the job. 
a) clear 
b) complete 
c) concise 
d) all of the above - ANSWERd) all of the abov...
- Package deal
- Exam (elaborations)
- • 11 pages •
Ch. 1-1 The ability to utilize all types of communication skills is ________ to the HVACR technician. 
a) not as important as "hands-on" technical skills 
b) somewhat important 
c) unimportant 
d) very important - ANSWERd) very important 
 
Ch. 1-2 It is important to be _______ in filling out service orders so that office staff, other technicians, and customers will know what work you completed on the job. 
a) clear 
b) complete 
c) concise 
d) all of the above - ANSWERd) all of the abov...
NATE Practice Exam CORRECT 100%
A suction line accumulator should be used in a residential heating pump only when recommended by the manufacturer if: 
 
a. Long refrigerant lines increase system charge over recommended maximum charge 
 
b. added oil dilution is required to maintain proper lubrication 
 
c. the system has low vapor line pressure drop and accumulator is added to improve efficiency 
 
d. the system does not include a high pressure switch or time delay - ANSWERA. Long refrigerant lines increase system charge ove...
- Package deal
- Exam (elaborations)
- • 36 pages •
A suction line accumulator should be used in a residential heating pump only when recommended by the manufacturer if: 
 
a. Long refrigerant lines increase system charge over recommended maximum charge 
 
b. added oil dilution is required to maintain proper lubrication 
 
c. the system has low vapor line pressure drop and accumulator is added to improve efficiency 
 
d. the system does not include a high pressure switch or time delay - ANSWERA. Long refrigerant lines increase system charge ove...
NATE: Air Conditioning Components CORRECT 100%
The part of an air conditioning system that changes the refrigerant from a low-pressure gas to a high-pressure gas is the: - ANSWERcompressor 
 
The part of an air conditioning system that changes the refrigerant from a high-pressure gas to a high-pressure liquid is the: - ANSWERcondenser 
 
The part of an air conditioning system that changes the refrigerant from a low-pressure liquid to a low-pressure gas is the: - ANSWERevaporator 
 
A split-system air conditioning unit has: - ANSWERthe compre...
- Package deal
- Exam (elaborations)
- • 3 pages •
The part of an air conditioning system that changes the refrigerant from a low-pressure gas to a high-pressure gas is the: - ANSWERcompressor 
 
The part of an air conditioning system that changes the refrigerant from a high-pressure gas to a high-pressure liquid is the: - ANSWERcondenser 
 
The part of an air conditioning system that changes the refrigerant from a low-pressure liquid to a low-pressure gas is the: - ANSWERevaporator 
 
A split-system air conditioning unit has: - ANSWERthe compre...
NATE AC Service Certification Questions & Answers(RATED A+)
A system is supplied from the factory with a charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? 
 
A. 6 ounces 
B. 5 pounds 
C. 5 pounds 10 ounces 
D. 6 pounds - ANSWERD. 6 pounds 
 
25ft - 15ft = 10ft 
10ft x .6 = 6 ounces 
5 pounds + 10 ounces + 6 ounces 
5 pounds + 16...
- Package deal
- Exam (elaborations)
- • 8 pages •
A system is supplied from the factory with a charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? 
 
A. 6 ounces 
B. 5 pounds 
C. 5 pounds 10 ounces 
D. 6 pounds - ANSWERD. 6 pounds 
 
25ft - 15ft = 10ft 
10ft x .6 = 6 ounces 
5 pounds + 10 ounces + 6 ounces 
5 pounds + 16...
ENPC Test Questions 2 |Answers|100% Verified Correct!!!
This must be a joke. So many obvious wrong answers. How did this get on Stuvia? Apparently no quality control at Stuvia.
State of Colorado Sales License Test Questions With Correct Answers| Verified!!
State of Colorado Sales License Test Questions With Correct Answers| Verified!!
Thanks