API 574 for API 570 Questions and Answers 100% Pass
- Exam (elaborations) • 36 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
API 574 for API 570 Questions and 
 
Answers 100% Pass 
 
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, does not 
cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS A 
 
The refining industry generally uses what type piping for severe service? 
a. brass 
 
b. cast 
c. seamless 
 
d. longitudinal seam welded C 
 
Piping made by rolling plates to size and welding the seams is large...
-
API 574 for API 570 Questions and Answers 100% Pass
- Exam (elaborations) • 36 pages • 2024
-
- $11.49
- + learn more
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, does not 
cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS A 
The refining industry generally uses what type piping for severe service? 
a. brass 
b. cast 
c. seamless 
d. longitudinal seam welded C 
Piping made by rolling plates to size and welding the seams is larger than ______ inches outside 
diameter. 
a. 10b. 16 
c. 14 
d. 12 ...
-
API 574 for API 570 Exam Questions and Answers 100% Pass
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
API 574 for API 570 Exam Questions and 
Answers 100% Pass 
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, 
does not cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS - Answer- A 
The refining industry generally uses what type piping for severe service? 
a. brass 
b. cast 
c. seamless 
d. longitudinal seam welded - Answer- C 
Piping made by rolling plates to size and welding the s...
-
API 574 for API 570 Exam Study Questions and Answers 2024
- Exam (elaborations) • 15 pages • 2024
-
- $11.99
- + learn more
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, does not cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS - A 
 
The refining industry generally uses what type piping for severe service? 
a. brass 
b. cast 
c. seamless 
d. longitudinal seam welded - C 
 
Piping made by rolling plates to size and welding the seams is larger than ______ inches outside diameter. 
a. 10 
b. 16 
c. 14...
-
API 570 - Open Book - Exam Questions With Revised Correct Detailed Answers Guarantee Pass
- Exam (elaborations) • 18 pages • 2024
-
Available in package deal
-
- $11.34
- + learn more
API 570 - Open Book - Exam 
Questions With Revised Correct 
Detailed Answers 
Guarantee Pass 
1) What is the maximum allowed hydrotest pressure for piping with class 300 
flanges that are made of ASTM 182 Gr. F316 Material? The Design 
Temperature is 600 °F - ASME B16.5: 2.6, Tables 1.1-1 & 2-2.2c 
1100 Psig. 
2) What is the required preheat temperature for an A106 Gr. B pipe with 
carbon content less than 0.2% and has a wall thickness of 0.500"? - ASME 
B31.3: Table 330.1.1 
50 ...
Get paid weekly? You can!
-
API 574 for API 570 Exam Questions and Answers 100% Pass
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
API 574 for API 570 Exam Questions and 
Answers 100% Pass 
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, 
does not cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS - Answer- A 
The refining industry generally uses what type piping for severe service? 
a. brass 
b. cast 
c. seamless 
d. longitudinal seam welded - Answer- C 
Piping made by rolling plates to size and welding the s...
-
API 570 Open Book Exam Questions and Answers 100% Pass
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
API 570 Open Book Exam Questions and 
Answers 100% Pass 
A hydrotest is being conducted on an underground line as a substitute for the external 
inspection. The test pressure is 200 psig. At the end of the test, the pressure must be at 
least: - Answer- C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design 
temperature of 950 degrees F. The flange material is ASTM A217 gr.C12 - Answer- B. 
375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B mater...
-
Pipefitter Star Exam (All possible questions with 100% correct answers; A+ GUARANTEED)
- Exam (elaborations) • 48 pages • 2023
- Available in package deal
-
- $17.99
- + learn more
What causes 90% of all construction injuries and deaths and are used to help OSHA inspectors improve their effectiveness? correct answers Focus Hazards 
 
What is the minimum safe working distance for overhead power lines? correct answers 10 feet 
 
What is the standard procedure used to safely de-energize equipment on circuits before they are worked on? correct answers Lockout/Tagout 
 
Which of the following is not true about Material Safety Data Sheets? correct answers They can be written in ...
-
API 574 for API 570 Questions Answered & Graded 2024/25
- Exam (elaborations) • 15 pages • 2024
-
Available in package deal
-
- $9.99
- + learn more
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, does not cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS 
A 
Track progress 
API Recommended Practice 574, Inspection of Piping, Tubing Valves, and Fittings, does not cover: 
a. control valves. 
b. piping smaller than 2" NPS. 
c. tubing smaller than 1.5" diameter. 
d. fittings smaller than 2" NPS - Correct Answer A...
-
API 570 Open Book Exam Questions and Answers 100% Pass
- Exam (elaborations) • 8 pages • 2024
-
- $12.49
- + learn more
API 570 Open Book Exam Questions and 
Answers 100% Pass 
A hydrotest is being conducted on an underground line as a substitute for the external 
inspection. The test pressure is 200 psig. At the end of the test, the pressure must be at 
least: - Answer- C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design 
temperature of 950 degrees F. The flange material is ASTM A217 gr.C12 - Answer- B. 
375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B mater...