EPA Lead Inspector questions and answers latest top score.
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $10.99
- 1x sold
- + learn more
EPA Lead Inspector questions and answers latest top score. 
 
 
 
 
 
 
 
 
 
 
 
 
Lead-based paint (LBP) - correct answers.Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 
 
Dust sample clearance values - correct answers.- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troug...
-
EPA LEAD INSPECTOR EXAM PREP QUESTIONS AND ANSWERS GRADED A+
- Exam (elaborations) • 16 pages • 2023
- Available in package deal
-
- $12.99
- 12x sold
- + learn more
EPA LEAD INSPECTOR EXAM PREP QUESTIONS AND ANSWERS GRADED A+
-
EPA Lead Inspector 2023 Exam Questions And Answers
- Exam (elaborations) • 7 pages • 2023
-
Available in package deal
-
- $14.99
- 2x sold
- + learn more
EPA Lead Inspector 2023 Exam Questions And Answers
-
EPA Lead Inspector (Actual Test 100% verified; correctly solved)
- Exam (elaborations) • 9 pages • 2023
- Available in package deal
-
- $10.59
- 1x sold
- + learn more
Lead-based paint (LBP) correct answers Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 
 
Dust sample clearance values correct answers - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft > 2 sq ft (can be r...
-
EPA Lead Inspector Exam bundle With 100% Correct Answers 2023
- Package deal • 10 items • 2023
-
- $30.49
- 1x sold
- + learn more
EPA Lead Inspector Exam bundle With 100% Correct Answers 2023
Fear of missing out? Then don’t!
-
EPA Lead Inspector Latest Update Graded A+
- Exam (elaborations) • 19 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
EPA Lead Inspector Latest Update 
 
Graded A+ 
 
Lead-based paint (LBP) Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 
0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead 
standard was updated to 1.0 
 
Dust sample clearance values - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 
250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in 
NY) - Samples must be at 1 sq ft &...
-
EPA LEAD INSPECTOR EXAM AND 2024-2025 QUESTIONS AND ANSWERS
- Exam (elaborations) • 31 pages • 2024
-
- $13.99
- + learn more
What do lead based paint inspections focus on? -Correct Answer they focus attention on the sources of lead that could poison children and reduce the cost of lead hazard control by identifying which surfaces are coated with lead-based paint. 
 
What are certified inspectors capable of? -Correct Answer 1. identifying the lead-based painted surfaces in housing 
2. Certify the results of an inspection in writing. 
3. Conduct post-hazard control clearance sampling to determine if 
a. the specified...
-
EPA Lead Inspector Questions and Answers Graded A+
- Exam (elaborations) • 19 pages • 2024
-
- $9.99
- + learn more
EPA Lead Inspector Questions and 
 
Answers Graded A+ 
 
Lead-based paint (LBP) Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 
0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead 
standard was updated to 1.0 
 
Dust sample clearance values - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 
250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in 
NY) - Samples must be at 1...
-
EPA Lead Inspector Exam Questions and Answers 2024/2025 (Solved 100%)
- Exam (elaborations) • 25 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
EPA Lead Inspector Exam Questions and Answers 2024/2025 (Solved 100%) Permanent abatement options include... - ANSWER-Paint removal, component 
removal, enclosure, encapsulation 
What agencies focus on childhood lead poisoning prevention? - ANSWER-CDPH, HUD, 
EPA 
What is the CAL OSHA Standard for lead? - ANSWER-Title 8 CCR 1532.1 
What is the Guidelines for the Evaluation and Control of Lead Based Paint Hazards in 
Housing? - ANSWER-1995 HUD Guidelines 