Real time transmission constraints or contingencies may be alleviated with generators operating : 
 
A. below 60 hertz 
B. on a new price curve 
C. on a new cost curve 
D. off cost ( out of merit) - correct answer D. off cost ( out of merit ) 
 
Monitoring LMP may give insights into : 
 
A. system constraints 
B. system voltage 
C. system frefuency 
D. time error - correct answer A. system constraints 
 
PJM calls for which of the following to recover the ACE so that tie line schedules are m...
-
PJM EXAM &PRACTICE EXAM 2024/2025 NEWEST!! COMPLETE ACTUAL 1032 (FROM 6 VERSIONS ) EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS ALREADY GRADED A+.
- Exam (elaborations) • 165 pages • 2024
-
- $26.99
- + learn more
PJM EXAM &PRACTICE EXAM 2024/2025 NEWEST!! COMPLETE ACTUAL 1032 
(FROM 6 VERSIONS ) EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED 
ANSWERS ALREADY GRADED A+. 
 
PJM EXAM &PRACTICE EXAM 2024/2025 NEWEST!! COMPLETE ACTUAL 1032 
(FROM 6 VERSIONS ) EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED 
ANSWERS ALREADY GRADED A+. 
 
PJM EXAM &PRACTICE EXAM 2024/2025 NEWEST!! COMPLETE ACTUAL 1032 
(FROM 6 VERSIONS ) EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED 
ANSWERS ALREADY GRADED A+. 
PJM EXAM &PRACTICE ...
-
PJM Generation Dispatch Exam 2024 with 100% correct answers
- Exam (elaborations) • 6 pages • 2024
-
- $16.49
- + learn more
Which of the following statements is correct concerning PJM assuming frequency control of the restoration process? 
 
A) PJM assumes control once an external transmission tie has been established. 
B) Once an Area Control Error can be calculated, PJM will assume control. 
C) Whenever it becomes too much of a burden for any one Transmission Owner within the RTO 
D) Whenever the Transmission Owners within the RTO agree to let PJM control the process. - correct answer C) Whenever it becomes too m...
-
PJM TRANSMISSION EXAM STUDY (PJM TRANSMISSION EXAM STUDY MATERIAL AS OF 6/30/2024) QUESTIONS CORRECTLY ANSWERED!!
- Exam (elaborations) • 35 pages • 2024
-
- $23.99
- + learn more
PJM TRANSMISSION EXAM STUDY (PJM TRANSMISSION EXAM STUDY MATERIAL AS OF 6/30/2024) QUESTIONS CORRECTLY ANSWERED!!
Get paid weekly? You can!
-
PJM Generation Operation Exam 2024 |Questions with Complete Solutions
- Exam (elaborations) • 8 pages • 2024
-
- $12.49
- + learn more
Control center facilities must have a minimum of how many days of fuel for the backup 
generator? - 5 days 
If PJM ACE shows overgeneration, actual imports are: - Less than scheduled 
Who should a generator contact at PJM to clear an outage ticket? - Master Coordinator 
To correct for a slow or fast clock, system frequency schedules are offset by: - +/-.02 Hz 
What frequency would PJM set to correct for fast-time error? - 59.98Hz 
What frequency would PJM set to correct for slow-time error? - 60...
-
PJM Transmission Exam Study Guide | Questions with 100% Correct Answers | Verified| Latest Updated 2024.
- Exam (elaborations) • 39 pages • 2024
-
- $13.99
- + learn more
PJM Transmission Exam Study Guide | Questions with 100% Correct Answers | Verified| Latest Updated 2024. 
During System Restoration, what is the optimal Frequency Range? 
59.75 - 61 Hz 
The 500 kV system has normal bus voltages between? 
500 to 550 kVRead More 
When Connecting 2 islands, the operator must match? 
Voltage, Phase Angle and Frequency 
What are the Minimum Source Requirements for a 500kV line? (Gen/mile and load/mile) 
30 MW Gen/mile of energized 500 kV and 20 MW Load/mile of energi...
-
PJM Practice Exam 2024 | Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
Real time transmission constraints or contingencies may be alleviated with generators 
operating________. A. below 60 Hz. B. on a new price curve. C. on a new cost curve. D. off cost (out of 
merit). - off cost (out of merit) 
What is the minimum size for a solar park to be required to have real and reactive power 
telemetry? A. 1 MW. B. 3 MW C. 5 MW D. 7 MW - 3 MW 
PJM calls for which of the following to recover the ACE so that tie line schedules are maintained? A. 
instantaneous reserve check ...
-
PJM 6910 Capstone Final Exam Actual Questions and Answers 2024/2025 Solved 100%;Northeastern University
- Exam (elaborations) • 12 pages • 2024
-
- $16.49
- + learn more
PJM 6910 Capstone Final Exam Actual Questions and Answers 2024/2025 Solved 100%;Northeastern University 
PJM 6910 Capstone Final Exam Actual Questions and Answers 2024/2025 Solved 100%;Northeastern University
-
PJM Generation Dispatch Exam | Questions And Answer | 2024 Updated Quiz
- Exam (elaborations) • 57 pages • 2024
-
Available in package deal
-
- $13.99
- + learn more
PJM Generation Dispatch Exam | Questions And Answer | 2024 Updated Quiz 
 
PJM Generation Dispatch Exam | Questions And Answer | 2024 Updated Quiz
That summary you just bought made someone very happy. Also get paid weekly? Sell your study resources on Stuvia! Discover all about earning on Stuvia