Arrt regis - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Arrt regis? On this page you'll find 664 study documents about Arrt regis.
Page 4 out of 664 results
Sort by
-
ARRT Registry Exam review (Graded A+ actual test)
- Exam (elaborations) • 110 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
What is the correct term used to describe an intravenous injection of a concentrated volume of contrast 
media? 
a. bolus 
b. infusion 
c. extravasation 
d. luminal - a. bolus 
Which of the following methods utilizes a detector that captures x-ray energy and converts it into an 
electronic signal? 
a. indirect capture 
b. CCD 
c. cassette based radiography 
d. direct capture - d. direct capture 
The energy of a characteristic x-ray photon created when an L shell electron fills a K shell vacancy ...
-
ARRT review - MRI registry review program questions and answers
- Exam (elaborations) • 132 pages • 2024
- Available in package deal
-
- $15.49
- + learn more
An RF pulse of what flip angle will maximize the component of the net magnetization projected into the transverse plane? 
 
a. 180 
b. 120 
c. 90 
d. 45 
c. 
 
 
 
T1 relaxation refers to ____ relaxation. 
 
a. spin-spin 
b. longitudinal 
c. phase 
d. transverse 
b. 
 
 
 
Which of the following statements is false? 
 
a. T1 relaxation refers to longitudinal recovery of magnetization while T2 relaxation refers to the transverse decay of magnetization 
b. T1 relaxation and T2 relaxation occur sim...
-
ARRT Registry Exam QUESTIONS AND ANSWER 2024/2025 FULLY SOLVED 100%
- Exam (elaborations) • 66 pages • 2024
- Available in package deal
-
- $13.48
- + learn more
ARRT Registry Exam QUESTIONS AND ANSWER 2024/2025 
FULLY SOLVED 100% 
What is the correct term used to describe an intravenous injection of a concentrated 
volume of contrast media? 
a. bolus 
b. infusion 
c. extravasation 
d. luminal - Answer a. bolus 
Which of the following methods utilizes a detector that captures x-ray energy and converts it 
into an electronic signal? 
a. indirect capture 
b. CCD 
c. cassette based radiography 
d. direct capture - Answer d. direct capture 
The energy of a c...
-
ARRT REGISTRY PROCEDURES questions and answers
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
sthenic 
average build 
 
 
 
hyposthenic 
slender 
 
 
 
asthenic 
extremely thin 
 
 
 
hypersthenic 
above average or massive build 
 
 
 
what landmark corresponds to C4-5? 
thyroid cartilage 
 
 
 
what landmark corresponds to the sternal notch? 
T2,3 
 
 
 
what landmark corresponds to the sternal angle? 
T4,5 
 
 
 
what landmark corresponds to the inferior angle of the scapula? 
T7 
 
 
 
what landmark corresponds to the xiphoid tip? 
T10 
 
 
 
what landmark corresponds to the level of ...
-
ARRT REGISTRY EXAM LATEST UPDATE LATEST 280 REAL EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) | AGRADE
- Exam (elaborations) • 47 pages • 2024
-
- $15.00
- + learn more
Which of the following medications is administered to a patient during an allergic reaction? 
A. Adenocard 
B. Intropin 
C. Lasix 
D. Decadron - D. Decadron 
What is the correct term used to describe an intravenous injection of a concentrated volume of contrast media? 
A. Bolus 
B. Infusion 
C. Extravasation 
D. Luminal - A. Bolus 
Identify the position that will place the positive contrast agent in the body of the stomach and pylorus during a double contrast upper GI exam 
A. Recumbent LPO 
B. ...
Get paid weekly? You can!
-
ARRT REGISTRY EXAM LATEST UPDATE LATEST 200 REAL EXAM QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) | A GRADE
- Exam (elaborations) • 71 pages • 2024
-
- $15.00
- + learn more
What is the correct term used to describe an intravenous injection of a concentrated 
volume of contrast media? 
a. bolus 
b. infusion 
c. extravasation 
d. luminal - Answer a. bolus 
Which of the following methods utilizes a detector that captures x-ray energy and 
converts it into an electronic signal? 
a. indirect capture 
b. CCD 
c. cassette based radiography 
d. direct capture - Answer d. direct capture 
The energy of a characteristic x-ray photon created when an L shell electron fills a K ...
-
ARRT Registry Review 1 questions and answers
- Exam (elaborations) • 21 pages • 2024
- Available in package deal
-
- $15.99
- + learn more
What most effectively minimizes radiation exposure to the patient? 
Beam restriction 
 
 
 
Radiographic subjects composed of just a few, very dissimilar tissue densities are likely to produce: 
High radiographic contrast 
 
 
 
In which of the following positions are the pyloric canal and duodenal bulb best demonstrated during a GI series? 
A. RAO 
B. left lateral 
C. recumbent PA 
D. recumbent AP 
A. RAO 
 
 
 
According to NCRP regulations, leakage radiation from the x-ray tube must NOT excee...
-
Arrt ct registry Questions and Answers 100% Pass
- Exam (elaborations) • 52 pages • 2024
-
- $13.49
- + learn more
Arrt ct registry Questions and Answers 100% Pass 
1. 
The normal range of respiration of an adult is 
A. 5- 10 breaths per minute 
B. 12-20 breaths per minute 
c. 20-30 breaths per minute 
D. 35-50 breaths per minute - Correct Answer ️️ -B. 12-20 
2 
which of the following is a parenteral route of medication administration 
A. sublingual 
B. Intramuscular 
C. transdermal 
D. Oral - Correct Answer ️️ -B. Intramuscular 
3 
The preperation for a contrast- enhanced CT exam of a patient with ...
-
Arrt ct registry Questions & Answers Rated 100% Correct!!
- Exam (elaborations) • 45 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
1. 
The normal range of respiration of an adult is 
A. 5- 10 breaths per minute 
B. 12-20 breaths per minute 
c. 20-30 breaths per minute 
D. 35-50 breaths per minute - Answer-B. 12-20 
2 
which of the following is a parenteral route of medication administration 
A. sublingual 
B. Intramuscular 
C. transdermal 
D. Oral - Answer-B. Intramuscular 
3 
The preperation for a contrast- enhanced CT exam of a patient with prior allergic reaction to iodinated 
contrast media may include 
A. pre medicatio...
-
CT Registry Review - ARRT questions and answers
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $12.99
- + learn more
Absorbed dose 
the amount of energy absorbed per unit mass 
(grays or rads) 
 
 
 
back projection 
- 3rd step in IR loop of iterative reconstruction algorithm 
- ray sum data are projected back onto a matrix. 
 
 
 
blood urea nitrogen (BUN) 
renal function (nitrogen in blood) 
(7-25mg/dl) 
 
 
 
bow-tie filter 
Filter compensating for a cylindrical shape (body) 
-filter is thicker at the ends 
 
 
 
contiguous images 
images with equal section thicknesses & reconstruction intervals 
 
 
 
Alia...