An electri - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about An electri? On this page you'll find 957 study documents about An electri.

Page 4 out of 957 results

Sort by

NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.
  • NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.

  • Exam (elaborations) • 18 pages • 2023
  • NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.
    (0)
  • $15.99
  • + learn more
Journeyman Electrician Exam 3
  • Journeyman Electrician Exam 3

  • Exam (elaborations) • 11 pages • 2024
  • Journeyman Electrician Exam 3 Where a water pipe passes over an indoor motor control center, leak protection apparatus shall have a MINIMUM clearance of _____. a) 6 feet to the protection apparatus b) 6 feet to the water pipe c) 6 1⁄2 feet to the protection apparatus d) 6 1⁄2 feet to the water pipe - A: 6 feet to the protection apparatus Ref: 110.26(F)(1)(a) Branch circuit grounded conductors that are not connected to an overcurrent device shall be permitted to be sized at LEA...
    (0)
  • $9.99
  • + learn more
Journeyman Electrician Practice Exam #7
  • Journeyman Electrician Practice Exam #7

  • Exam (elaborations) • 13 pages • 2024
  • Journeyman Electrician Practice Exam #7 Where the outer sheath of Type MI cable is made of steel _____________. A. it shall provide an adequate path to serve as an equipment grounding conductor B. a separate equipment grounding conductor shall be provided C. the grounding and grounded conductors shall be connected together D. it shall not be longer than 6 feet - B. a separate equipment grounding conductor shall be provided The interior of enclosures or raceways installed under...
    (0)
  • $9.99
  • + learn more
NYC Electrician Exam Q&A PASSED TEST
  • NYC Electrician Exam Q&A PASSED TEST

  • Exam (elaborations) • 19 pages • 2024
  • NYC Electrician Exam Q&A PASSED TEST The value of current, time, or both at which an adjustable circuit breaker is set to trip is known as? A) Inverse time B) Ampacity C) Automatic D) Setting - ANSWER D) Setting. The cross-sectional area of three or more THW conductors in a conduit must not exceed what percent of the cross-sectional area of the conduit? A) 30% B) 40% C) 50% D) 60% - ANSWER B) 40 % Chapter 9 Table 1 EMT must be supported within what distance from an outlet b...
    (0)
  • $12.49
  • + learn more
MASTER ELECTRICIAN EXAM REVIEW
  • MASTER ELECTRICIAN EXAM REVIEW

  • Exam (elaborations) • 12 pages • 2024
  • MASTER ELECTRICIAN EXAM REVIEW
    (0)
  • $12.49
  • + learn more
Master Electrician Exam Review Questions and Answers 100% Correct
  • Master Electrician Exam Review Questions and Answers 100% Correct

  • Exam (elaborations) • 12 pages • 2024
  • Master Electrician Exam Review Questions and Answers 100% CorrectMaster Electrician Exam Review Questions and Answers 100% CorrectMaster Electrician Exam Review Questions and Answers 100% Correct branch circuit - ANSWER-That portion of a wiring system extending beyond the final overcurrent device is called the: Calculated load - ANSWER-The final sum of the computed loads, based on the minimum code requirements, is the Resistance - ANSWER-As compared to #10, a #8 wire of the same Iength ha...
    (0)
  • $11.49
  • + learn more
Journeyman electrician exam prep 2024
  • Journeyman electrician exam prep 2024

  • Exam (elaborations) • 10 pages • 2024
  • Available in package deal
  • Journeyman electrician exam prep 2024 What table sizes bonding jumpers for for AC systems? -Answer-250.102(C)(1) The NEC defines continuous load to be a load where max current on the circuit continues for at least how many hours? -Answer-Three To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many current carrying conductors in a raceway? -Answer-Greater than three Where in the NEC codebook would you find EMT sizes for a given size and number of conduc...
    (0)
  • $12.49
  • + learn more
RESIDENTIAL ELECTRICIAN EXAM #2
  • RESIDENTIAL ELECTRICIAN EXAM #2

  • Exam (elaborations) • 5 pages • 2024
  • The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. a) 12 inches b) 18 inches c) 20 inches d) 24 inches - Answer-C: 20 inches Ref: 210.52(C)(5) For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. a) hallways b) garages c) kitchens d) bathrooms - Answer-D: bathrooms Ref: 240.24(E) The MAXIMUM number of grounded conductors allowed to be terminated in an individual terminal,...
    (0)
  • $10.99
  • + learn more