ACI Grade 1 - Written Test Questions & 100% Verified Answers | Latest Update | Already Graded A+
- Exam (elaborations) • 46 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Sampling by this practice covers procedures for obtaining representative samples, on 
which tests are to be performed to determine ___ with quality requirements of the 
specifications listed under which the concrete is furnished (C172/C172M-17 = Sampling 
Freshly Mixed Concrete) 
: Compliance 
This practice covers sampling from five types of equipment which are... (C172/C172M17 = Sampling Freshly Mixed Concrete) 
: Stationary, paving, revolving drum, continous, and open top mixers 
The elaps...
-
ACI Grade 1 - Written Test Questions With 100% Correct Answers 2024/2025
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
ACI Grade 1 - Written Test Questions With 
100% Correct Answers 2024/2025 
Sampling by this practice covers procedures for obtaining representative samples, on which 
tests are to be performed to determine ___ with quality requirements of the specifications 
listed under which the concrete is furnished (C172/C172M-17 = Sampling Freshly Mixed 
Concrete) - answerCompliance 
This practice covers sampling from five types of equipment which are... (C172/C172M-17 = 
Sampling Freshly Mixed Concrete) - ...
-
ACI Grade 1 Field Testing Certification Practice Test – 100% Solved
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
ACI Grade 1 Field Testing Certification 
Practice Test – 100% Solved 
For concrete with aggregates less than 3 inches, the thermometer must remain in the 
fresh concrete sample a minimum of 5 minutes or until the temperature reading 
stabilizes. (T or F) -Answer-False (2-5 minutes) 
The temperature measuring device must be accurate to within 0.1 degree. (T or F) - 
Answer- 
The temperature measuring device shall have a capacity of measuring temperature of 
freshly mixed concrete throughout a r...
-
ACI Grade 1 - Written Test Questions With 100% Correct Answers 2024/2025
- Exam (elaborations) • 22 pages • 2024
-
- $13.49
- + learn more
ACI Grade 1 - Written Test Questions With 
100% Correct Answers 2024/2025 
Sampling by this practice covers procedures for obtaining representative samples, on which 
tests are to be performed to determine ___ with quality requirements of the specifications 
listed under which the concrete is furnished (C172/C172M-17 = Sampling Freshly Mixed 
Concrete) - answerCompliance 
This practice covers sampling from five types of equipment which are... (C172/C172M-17 = 
Sampling Freshly Mixed Concrete) - ...
-
ACI Grade 1 Field Testing Certification Practice Test Questions with Answers 100% Correct
- Exam (elaborations) • 9 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
ACI Grade 1 Field Testing Certification Practice Test 
Questions with Answers 100% Correct 
For concrete with aggregates less than 3 inches, the thermometer must remain in the 
fresh concrete sample a minimum of 5 minutes or until the temperature reading 
stabilizes. (True or False) - Answer- False 
The temperature measuring device must be accurate to within 0.1 degrees. (True or 
False) - Answer- False 
The temperature measuring device shall have a capacity of measuring temperature of 
freshly ...
And that's how you make extra money
-
ACI Grade 1 Field Testing Certification Practice Test – Irving Questions and Answers
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
ACI Grade 1 Field Testing Certification Practice Test 
– Irving Questions and Answers 
For concrete with aggregates less than 3 inches, the thermometer must remain in the 
fresh concrete sample a minimum of 5 minutes or until the temperature reading 
stabilizes. (T or F) - Answer-False (2-5 minutes) 
The temperature measuring device must be accurate to within 0.1 degree. (T or F) - 
Answer- 
The temperature measuring device shall have a capacity of measuring temperature of 
freshly mixed concr...
-
ACI Concrete Field Testing Technician- Grade I | 140 Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 14 pages • 2023
- Available in package deal
-
- $15.49
- 1x sold
- + learn more
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. 
[_____mm] into the freshly mixed concrete. - 3 in. [75 mm] 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed 
concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - 1 degree F [0.5 C], 30 
degrees F to 120 F [0 C to 50 C] 
The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. - 
Annually, accu...
-
ACI Grade 1 Field Testing Certification Practice Test – Irving Correctly Answered Questions| UpToDate | Already Graded A+
- Exam (elaborations) • 17 pages • 2024
-
- $12.49
- + learn more
For concrete with aggregates less than 3 inches, the thermometer must remain in the 
fresh concrete sample a minimum of 5 minutes or until the temperature reading 
stabilizes. (T or F) ☑: False (2-5 minutes) 
The temperature measuring device must be accurate to within 0.1 degree. (T or F) ☑: 
The temperature measuring device shall have a capacity of measuring temperature of 
freshly mixed concrete throughout a range of _____ to _____ degree F ( ______ to 
______ degree C) ☑: 30 to 120...
-
ACI Grade 1 Field Testing Certification Practice Test - 2024
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
ACI Grade 1 Field Testing Certification 
Practice Test - 2024 
For concrete with aggregates less than 3 inches, the thermometer must remain in the 
fresh concrete sample a minimum of 5 minutes or until the temperature reading 
stabilizes. (T or F) -Answer-False (2-5 minutes) 
The temperature measuring device must be accurate to within 0.1 degree. (T or F) - 
Answer- 
The temperature measuring device shall have a capacity of measuring temperature of 
freshly mixed concrete throughout a range of _...
-
ICC Codes Exam Questions with Correct Answers.docx
- Exam (elaborations) • 7 pages • 2024
-
Available in package deal
-
- $13.59
- 1x sold
- + learn more
ICC Codes Exam Questions with Correct A 
 
Which of the following publications is most useful for a Special Inspector? - Answer-ACI 318 
 
A 	is a horizontal member that transfers loads laterally. - Answer-Beam 
 
Plain concrete refers to: - Answer-Concrete with less than the minimum amount of reinforcement 
 
Answer-Flexure, compression 
 
The best place to look up definitions in ACI 318-14 is: - Answer-Chapter 2 
 
Foundations cast at the same elevation as the soil grade are known as: - Answer...