Nicet level 1 2 3 - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Nicet level 1 2 3? On this page you'll find 104 study documents about Nicet level 1 2 3.
Page 3 out of 104 results
Sort by
-
Nicet level 1 Review Practice Exam Questions & Answers.
- Exam (elaborations) • 17 pages • 2024
-
Available in package deal
-
- $11.49
- + learn more
Nicet level 1 Review Practice Exam Questions & Answers. 
 
 
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) - CORRECT ANSWER rises or falls over 3 inches 
 
If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of _______. 
 
(Nfpa 72 18.4.8.1) - CORRECT ANSWER the visible ap...
-
Nicet Level 2: Concrete Exam Questions and Answers 2024
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Nicet Level 2: Concrete Exam Questions and Answers 2024 
What is the testing frequency for concrete? - Answer-every 50 yards 
When should you take cylinder samples? - Answer-Every 100 yards 
What are the components on a batch ticket? - Answer-1. Ticket Number 
2. Plant 
3. Project Number 
4. Mix ID 
5. Time of Batch 
6. Time arrival 
7. Time Discharge 
8. Time Completed 
9. Mix proportions 
When should concrete samples should not be taken? - Answer-Before 10% and 90% of 
truck has been discharge...
-
NICET Fire Alarm Level 1 Exam Questions And Revised Correct Answers
- Exam (elaborations) • 8 pages • 2024
-
- $12.99
- + learn more
NICET Fire Alarm Level 1 Exam Questions And Revised Correct Answers 
 
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? - Answer -18 months 
 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? - Answer -66 inches 
 
Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the center-line of the door? - Answer -21 fee...
-
NICET LEVEL 1 HIGHWAY CONSTRUCTION EXAM QUESTIONS AND ANSWERS
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
NICET LEVEL 1 HIGHWAY CONSTRUCTION EXAM 
QUESTIONS AND ANSWERS 
Acceptance - Answer-The written acceptance by the Department of the Work. 
acceptance testing - Answer-Testing conducted by the Department to measure the 
degree of compliance to the Contract 
actual cost - Answer-The computed cost using calculations provided 
addendum - Answer-A Contract revision or response to a Contractor inquiry issued after 
advertisement and before the opening of bids. 
as-built quantity - Answer-The quantity ...
-
NICET Level 1 - Water Based Layout Already Rated A+
- Exam (elaborations) • 15 pages • 2024
-
Available in package deal
-
- $10.49
- + learn more
NICET Level 1 - Water Based Layout Already Rated A+ 
Toggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size 
under ceilings of hollow tile or metal lath and plaster. 
1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
While conducting a flow test, the chosen hydrant should be ______ 
As close to the property 
where the sprinkler system is being installed. (Ref, NFPA 13 Sec. A.24.2.2. or NFPA 291) 
What formula is used to determine the discharge coef...
Want to regain your expenses?
-
NICET Level 2 NFPA 25: Standard for Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems Exam 2024
- Exam (elaborations) • 5 pages • 2024
-
- $11.49
- + learn more
NICET Level 2 NFPA 25: Standard for 
Inspection, Testing, and Maintenance 
of Water-Based Fire Protection 
Systems Exam 2024 
Chapter 1 - Answer-Administration 
Chapter 2 - Answer-Referenced Publications (Other NFPA Standards) 
Chapter 3 - Answer-Definitions 
Chapter 4 - Answer-General Requirements (Owner's Chapter) 
Chapter 5 - Answer-Sprinkler Systems (Heads, Hangers, Waterflow Alarm Devices, AF 
Systems, Dry Pipe Systems) 
Chapter 6 - Answer-Standpipe & Hose Systems 
Chapter 7 - Answer-Hydra...
-
NICET Level 2 Exam questions & Answers, rated A+[LATEST EXAM UPDATES]
- Exam (elaborations) • 7 pages • 2024
-
Available in package deal
-
- $8.49
- + learn more
NICET Level 2 Exam questions & 
Answers, rated A+ 
4 - Consider a room which is 40' square. How many 15cd wall mounted strobes are required to 
adequately cover this space? 
Annually - What is the testing frequency of a strobe? 
15 - In a corridor application, visible appliances shall be rated not less than ________ cd? 
4 hours - Consider a household fire alarm system where the primary power is provided by a circuit 
that can be switched off by means other than a circuit breaker. The batter...
-
TFM01 Exam Questions and Answers 100% Pass
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
TFM01 Exam Questions and Answers 
The fire marshal shall send notice to each examinee of the results of the examination no 
later than -Answer-30 days 
If the examination is conducted by a testing service the state marshal shall send notice 
of the results no later than -Answer-14 days 
If examination results will be delayed the state marshal shall send notice to the 
examinee no later than -Answer-90 days 
A renewal of a registration certificate or license is valid for a period of -Answer-2 yea...
-
Nicet Level 2 questions and answers 2024
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
Nicet Level 2 questions and answers 2024 
4 - Answer-Consider a room which is 40' square. How many 15cd wall mounted strobes 
are required to adequately cover this space? 
Annually - Answer-What is the testing frequency of a strobe? 
15 - Answer-In a corridor application, visible appliances shall be rated not less than 
________ cd? 
4 hours - Answer-Consider a household fire alarm system where the primary power is 
provided by a circuit that can be switched off by means other than a circuit br...
-
TCFP Fire Marshal with 100- correct answers(GUARANTEED SUCCESS)).
- Exam (elaborations) • 4 pages • 2024
-
- $12.99
- + learn more
A registered firm is defined as 
A person or organization holding a current certificate of registration 
 
 
 
An expired certificate or license of registration is no longer valid for renewal after 
2 years 
 
 
 
 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:00 
/ 
0:15 
Full screen 
Brainpower 
Read More 
New applications for certificates or licenses of registration must be signed by 
All owners of the company, the sole proprietor, OR by each partner of a compan...
How much did you already spend on Stuvia? Imagine there are plenty more of you out there paying for study notes, but this time YOU are the seller. Ka-ching! Discover all about earning on Stuvia