S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Answers All 100% Correct
- Exam (elaborations) • 23 pages • 2024
-
- $12.49
- + learn more
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 
sprinkler test Answers All 100% Correct 
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO 
DETERMINE QUALIFICATIONS. - Answer- OWNER 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES 
FOR A MIN. OF __________ YEARS. - Answer- 3 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH 
REQUIREMENTS. - Answer- IMPAIRMENT COORDINATOR 
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ 
FLOOR(S) ARE CONSIDERED ...
-
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test actual questions and answers with complete solution
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test 
actual questions and answers with complete solution 
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO 
DETERMINE QUALIFICATIONS. - Answer ️️ -OWNER 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES 
FOR A MIN. OF __________ YEARS. - Answer ️️ -3 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH 
REQUIREMENTS. - Answer ️️ -IMPAIRMENT COORDINATOR 
REGULAR MX AND MINOR REPAIRS NOT AFFECT...
-
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023
- Exam (elaborations) • 20 pages • 2023
-
- $8.39
- + learn more
THE __________ IS RESPO NSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. OWNER RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. 3 THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. IMPAIRMENT COORDINATOR REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED PLANNED REMOVAL FROM SERVICE. 1 SHUTDOWNS AFFECTING MORE THAN _________ FLOOR(S) ARE CONSIDERED UNPLANNED OUT OF SE...
-
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Questions With Complete Answers 100% Correct.
- Exam (elaborations) • 20 pages • 2024
-
Available in package deal
-
- $12.99
- + learn more
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. - correct answer OWNER 
 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. - correct answer 3 
 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. - correct answer IMPAIRMENT COORDINATOR 
 
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED PLANNED REM...
-
Z-51 REFRIGERATION TEST QUESTIONS AND ANSWERS 100% VERIFIED.
- Exam (elaborations) • 19 pages • 2024
-
- $13.49
- + learn more
Z-51 REFRIGERATION TEST QUESTIONS AND ANSWERS 100% VERIFIED. 
 
 
 
 
Efficiency of the refrigerant cycle is affected by the operations of the condenser. Of the following, a more efficient centrifugal compressor operation results from: - correct answer. Lowering the condensing pressure 
 
The heat removed from the refrigerant in a condenser is: - correct answer. Sensible and latent heat 
 
The refrigerant unit that you have been assigned to is being taken out of service for a major repair....
And that's how you make extra money
-
S-12 CITYWIDE SPRINKLER SYSTEMS ALREADY GRADED A+
- Exam (elaborations) • 11 pages • 2024
-
Available in package deal
-
- $10.49
- + learn more
S-12 CITYWIDE SPRINKLER SYSTEMS ALREADY GRADED A+ 
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. 
️OWNER 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF 
__________ YEARS. ️3 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. 
️IMPAIRMENT COORDINATOR 
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED 
PLANNED REMOVAL FROM SERVICE. ️1 
SHUT...
-
Refrigeration Machine Operator Exam 1 Questions with Correct Answers
- Exam (elaborations) • 16 pages • 2024
-
Available in package deal
-
- $16.49
- + learn more
efficiency of the refrigerant cycle is affected by the operations of the condenser. Of the following, a more efficient centrifugal compressor operation results from: - Answer-Lowering the condensing pressure 
 
The heat removed from the refrigerant in a condenser is: - Answer-sensible and latent heat 
 
The refrigerant unit that you have been assigned to is being taken out of service for a major repair. You have been assigned to withdraw refrigerant for storage in suitable containers. According ...
-
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023
- Exam (elaborations) • 25 pages • 2023
-
Available in package deal
-
- $10.49
- + learn more
S-12 CITYWIDE SPRINKLER SYSTEMS, 
S12 sprinkler test Spring 2023 
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND 
TO DETERMINE QUALIFICATIONS. 
OWNER 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON 
PREMISES FOR A MIN. OF __________ YEARS. 
3 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY 
WITH REQUIREMENTS. 
IMPAIRMENT COORDINATOR 
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN 
________ FLOOR(S) ARE CONSIDERED PLANNED REMOVAL FROM 
SERVICE. 
1 ...
-
FDNY Z-51 REFRIGERATION EXAM TEST QUESTIONS WITH CORRECT ANSWERS
- Exam (elaborations) • 18 pages • 2023
-
Available in package deal
-
- $11.99
- + learn more
FDNY Z-51 REFRIGERATION EXAM 
TEST QUESTIONS WITH CORRECT 
ANSWERS 
Efficiency of the refrigerant cycle is affected by the operations of the condenser. Of the 
following, a more efficient centrifugal compressor operation results from: - ANSWER 
Lowering the condensing pressure 
The heat removed from the refrigerant in a condenser is: - ANSWER Sensible and 
latent heat 
The refrigerant unit that you have been assigned to is being taken out of service for a 
major repair. You have been assig...
-
S12 Certificate of Fitness Sprinkler Exam Questions and Complete Solutions Graded A+
- Exam (elaborations) • 72 pages • 2024
- Available in package deal
-
- $13.49
- + learn more

 
When the pump is in operation a small water leak on the pump bearings is desirable and should not be considered a malfunction. Additionally, water should discharge from a ---- relief valve (electric pump) or --- exchanger (diesel pump) while the fire pump is operating under a "no-flow" condition. - Answer: circulation /heat 
 
A sprinkler system is a - Answer: fire extinguishing system, other than a water mist system, that utilizes water as the extinguishing agent. 
 
Inspection, test...