Epa 608 stuvia - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Epa 608 stuvia? On this page you'll find 61 study documents about Epa 608 stuvia.
Page 3 out of 61 results
Sort by
-
EPA 608 Type III Complete Questions & Answers!!
- Exam (elaborations) • 11 pages • 2023
-
Available in package deal
-
- $10.49
- + learn more
What do R-11 and R-123 refrigerants have in common? 
 
A. They are oxygen depleting 
B. They are Class I and II substances as defined by the EPA 
C. Both A and B 
D. Neither A nor B - ANSWER C. Both A and B 
 
What is the required evacuation level for recovering refrigerant from a low-pressure appliance with a recovery machine manufactured before November 15, 1993? 
 
A. 0 psig 
B. 4" Hg 
C. 10 A Hg 
D. 25" Hg - ANSWER D. 25" Hg 
 
How is frost best removed from a sight glass? 
 
A. reverse ...
-
EPA 608: Type III Correct 100% Correct!!
- Exam (elaborations) • 5 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
Techs maintaining, servicing, repairing, or disposing of low pressure appliances must be certified as? - ANSWER Type III or universal technician 
 
As of what date was the sale of CFCs and HCFCs restricted to certified techs? - ANSWER Nov 14, 1994 
 
Who is responsible to comply with changes in section 608? - ANSWER The technician 
 
Because low pressure systems operate in a vacuum , where will leaks occur? - ANSWER Gaskets or fittings (allow air or moisture into the system? 
 
What is the most ...
-
EPA 608 Type III Practice Questions & Answers
- Exam (elaborations) • 3 pages • 2023
- Available in package deal
-
- $10.49
- + learn more
municipal water supply 
 
approximately how much refrigerant vapor is left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed? - ANSWER 100 lbs 
 
a rupture disc on a recovery vessel for low pressure refrigerant relieves at ____ - ANSWER 15 psig 
 
on a centrifugal system, the purge unit takes its suction from the ____ - ANSWER top of the condenser 
 
a centrifugal chiller's rupture disk is connected to the chiller's ______ - ANSWER evaporator 
 
wh...
-
EPA 608 Type 3 Correct Questions & Answers(Rated A+)
- Exam (elaborations) • 10 pages • 2023
-
Available in package deal
-
- $11.99
- + learn more
On low pressure chillers, moisture typically enters the refrigerant system through - ANSWER air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ANSWER 10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - ANSWER ... 
 
A hydrostatic tube test kit is used to: - ANSWER determine if a tube leaks 
 
Commercial and industrial process refrigeration systems must be repaired wh...
-
EPA 608 Type III| QUESTIONS| Correct Answers!
- Exam (elaborations) • 3 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
a Type III Technician or Universal Technician are certified to do what? - ANSWER Maintain, service, repair, or dispose of low-pressure appliances. 
 
Most low pressure appliances are used for what? - ANSWER Most low pressure appliances are used for comfort cooling and are subject to lower allowable leak rate. 
 
The owner and/or operator of the equipment is responsible for what? - ANSWER for keeping records of all leaking inspections and any completed leak repair verification tests. It is their ...
And that's how you make extra money
-
EPA SECTION 608 TYPE III| 25 Questions | Correct Answers
- Exam (elaborations) • 3 pages • 2023
- Available in package deal
-
- $11.49
- + learn more
Which of the following refrigerants 
has a safety classification of B-1 - ANSWER HCFC-123 (R-123) 
 
The EPA-required evacuation level for 
recovery or recycling equipment used on 
low-pressure systems is - ANSWER 25 mm of Hg absolute. 
 
Which organization establishes the refrigerant safety group standard? - ANSWER ASHRAE 
 
Where is the purge unit located in a low-pressure system? - ANSWER The top of the condenser. 
 
To repair a chiller operating with R-22, the technician; - ANSWER must ha...
-
EPA 608 TYPE III Correct Questions & Answers!!
- Exam (elaborations) • 2 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
A-1 - ANSWER refrigerants CFC-12, HCFC-22, HFC-134a are all classified as type what substances? 
 
15 hg - ANSWER when recovering refrigerant from a medium pressure system with more than 200lbs of refrigerant, recover to a level of? 
 
30% - ANSWER EPA requires that all industrial process refrigeration systems containing more than 50 lbs of refrigerant MUST be repaired when the annual leak rate excceds? 
 
pressurize system using controlled hot water - ANSWER whats the most efficient method of l...
-
EPA 608 Certification Correct Questions & Answers!!
- Exam (elaborations) • 5 pages • 2023
-
Available in package deal
-
- $9.99
- + learn more
What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? - ANSWER November 14, 1994 
 
Section 608 of the Federal Clean Air Act requires technicians to what? - ANSWER Recover all refrigerants. 
 
The objective of the Clean Air Act is to protect what? - ANSWER The earth's stratosphere. 
 
HFC's - ANSWER HydroFlouroCarbon's 
 
CFC's - ANSWER ChloroFluoroCarbon's 
 
ODP - ANSWER Ozone Depletion Potential 
 
Which international treaty agreement was...
-
EPA 608 Type III Sample Test Questions & Answers!!
- Exam (elaborations) • 9 pages • 2023
-
Available in package deal
-
- $11.99
- + learn more
Where do leaks commonly occur in low pressure systems? 
a. Evaporator 
b. Condenser 
c. Purge unit 
d. Gaskets or fittings - ANSWER d. Gaskets or fittings 
 
Where do leaks commonly occur in open-drive type compressor systems? 
a. Evaporator 
b. Condenser 
c. Shaft seal 
d. Cooling tower - ANSWER c. Shaft seal 
 
Does refrigerant go out of the system in low pressure systems or does air and 
moisture go in? 
a. Refrigerant escapes through low pressure leaks. 
b. Air and moisture enter the refrige...
-
EPA 608 Type III Correct Questions & Answers(Rated A+)
- Exam (elaborations) • 5 pages • 2023
-
Available in package deal
-
- $9.99
- + learn more
A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is: - ANSWER C) 10 psig. 
 
A charged low pressure refrigeration system can be efficiently leak checked by: - ANSWER D) raising system pressure by heating with circulated hot water or heating blankets. 
 
The existence of air in a low pressure system, causes __________. - ANSWER C) high head pressure. 
 
Which safety precaution should be adhered to for low pr...
Did you know that on average a seller on Stuvia earns $82 per month selling study resources? Hmm, hint, hint. Discover all about earning on Stuvia