Residential Wireman Electrician's Licensing Exam Already Solved 100%
- Exam (elaborations) • 23 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
NEC Article ______ defines breakers and fuses. - Answers According to NEC Article 100, a device that opens and closes a circuit by nonautomatic means automatically closes for a predetermined overcurrent. 
 
Annex _____ of NEC covers conduit fill. - Answers Annex C of NEC covers conduit and tubing fill for conductors and fixture wire fill. 
 
NEMA stands for National Electrical Manufacturers Association - Answers True - NEMA is the acronym for National Electrical Manufacturers Association. 
 
Wha...
-
Residential Wireman Electrical Wiring Midterm Exam With Complete Solution
- Exam (elaborations) • 17 pages • 2023
- Available in package deal
-
- $11.99
- + learn more
When nonmetallic device boxes that are 2-gang or more are used, the installed Type NM cable must be secured no more than __________ inches from the box. 
 
a.12 
b.10 
c.18 
d.8 - Answers a 12 
 
A low resistance path, which results in a high value of current that flows around, rather than through, a circuit is called a(n) __________ circuit. 
 
a. grounded 
 
b. short 
 
c. grounding 
 
d. open - Answers 
 
1. A ____________________-ampere overcurrent protection device is required for a reside...
-
Residential Wireman Electrical Exam - Larry Bobo Correct 100%
- Exam (elaborations) • 10 pages • 2023
-
Available in package deal
-
- $10.99
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - ANSWERS4 
 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
 
Continuity, Grounded conductors 
200.12 - ANSWERSwire. 
 
Each multi-wire branch circuit shall be provided with...
-
Residential Wireman Electrical Exam Questions With Correct Answers
- Exam (elaborations) • 15 pages • 2023
- Available in package deal
-
- $11.49
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - Answers 4 
 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
 
Continuity, Grounded conductors 
200.12 - Answers wire. 
 
Each multi-wire branch circuit shall be provided wi...
-
Residential Wireman Electrical Exam - Larry Bobo Questions & Answers Correct 100%
- Exam (elaborations) • 10 pages • 2023
-
Available in package deal
-
- $10.49
- + learn more
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper 
 
Ampacities, Grounding 
250.122(B) Table 250.122 Table 8 Ch 9 - ANSWERS4 
 
The continuity of the grounded conductor shall depend on a busbar or __ only. 
 
Continuity, Grounded conductors 
200.12 - ANSWERSwire. 
 
Each multi-wire branch circuit shall be provided with...
Make study stress less painful
-
Residential Wireman Electrical Wiring Midterm Exam Term 3 With Complete Solution
- Exam (elaborations) • 11 pages • 2023
- Available in package deal
-
- $10.99
- + learn more
1. A 20-ampere branch circuit requires _____ AWG conductors, ignoring the effects of voltage drop. 
a. 14 aluminum 
b. 14 copper 
c. 12 copper 
d. 12 aluminum - Answers 12 copper 
 
2. A continuous load shall not exceed _____ of the rating of the branch circuit. 
a. 125% 
b. 100% 
c. 50% 
d. 80% - Answers 80% 
 
3. A dual-rated conductor marked THHN/THWN is rated_____ when used in dry locations. 
a. 30°C (86°F) 
b. 90°C (194°F) 
c. 60°C (140°F) 
d. 75°C (167°F) - Answers 90°C 
 
4. A r...
-
Residential Wireman Electrician Exam #1 With Correct Solution
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $9.99
- + learn more
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - Answers A: electrically continuous 
Ref: 250.64(E) 
 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) switched receptacles for cord-connected incandescent luminaires 
b) permanently installed incandescent luminaires 
c) ceiling fans with luminaires...
-
Residential Wireman Electrical Exam #4 Already Solved 100%
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $9.99
- + learn more
When a single branch-circuit with an equipment grounding conductor is supplying a detached garage from a house, what, if any, additional grounding electrode(s) is/are required at the garage? 
a) A ground rod and underground metal water pipe. 
b) A metal underground water pipe only. 
c) A metal underground water pipe and building steel, if available. 
d) No additional electrodes are required. - Answers D: No additional electrodes are required. 
Ref: 250.32(A), Ex. 
 
The point of attachment of a ...
-
Residential Wireman Electrician Exam #3 Questions With Correct Answers
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $9.99
- + learn more
What is the MAXIMUM allowable cord length for the cord supplying a cord-and-plug connected dishwasher installed under a kitchen counter in a dwelling unit? 
a) 11⁄2 feet 
b) 2 feet 
c) 3 feet 
d) 4 feet - Answers D: 4 feet 
Ref: 422.16(B)(2)(2) 
 
What is the MINIMUM size copper SE cable with type THHW insulation that may be used as ungrounded, service-entrance phase conductors for a 150 ampere-rated, 120/240-volt, singlephase, residential service? 
a) 1/0 AWG 
b) 1 AWG 
c) 2 AWG 
d) 3 AWG - A...
-
Residential Wireman Electrician Exam #2 Questions & Answers 100% Correct
- Exam (elaborations) • 8 pages • 2023
- Available in package deal
-
- $9.99
- + learn more
The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches - Answers C: 20 inches 
Ref: 210.52(C)(5) 
 
For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. 
a) hallways 
b) garages 
c) kitchens 
d) bathrooms - Answers D: bathrooms 
Ref: 240.24(E) 
 
The MAXIMUM number of grounded conductors allowed to be terminated in an individual termina...