Mrso safety test - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Mrso safety test? On this page you'll find 35 study documents about Mrso safety test.
Page 2 out of 35 results
Sort by
-
MRSO EXAM Test Questions And Revised Correct Answers
- Exam (elaborations) • 39 pages • 2024
-
Available in package deal
-
- $11.34
- + learn more
MRSO EXAM Test Questions And 
Revised Correct Answers 
How do magnetic flux lines travel? 
A. North to South 
B. South to North 
C. East to West 
D. West to East - ANSWER : A North to South 
Which of the following can be potential safety concerns to 
a patient in the static magnetic field? 
A. Electrically conductive materials 
B. Ferrous objects 
C. Magnetic objects 
D. All of the choices. - ANSWER : D. All of the choices 
An object that retains its magnetic field when exiting the 
static ma...
-
MRSO Mock Test 1 with Questions and Answers.
- Exam (elaborations) • 28 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
MRSO Mock Test 1 with Questions and Answers. 
What pulse sequence will produce the most patient heating? 
A. Inverse recovery sequence 
B. Single shot fast spin echo 
C. Conventional spin echo 
D. Gradient Echo - Answer B. Single shot fast spin echo 
During acquisition, it is noticed that the T wave of the cardiac cycle is elevated. 
What is this artifact called? 
A. Magnetohydrodynamic Effect 
B. Excitation 
C. Teratogenesis 
D. Magnetophosphenes - Answer A. Magnetohyrdodynamic Effect 
When can...
-
MRSO Mock Test 1 with verified solutions 2024/2025
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $17.99
- + learn more
MRSO Mock Test 1What pulse sequence will produce the most patient heating? 
 
A. Inverse recovery sequence 
B. Single shot fast spin echo 
C. Conventional spin echo 
D. Gradient Echo - correct answer B. Single shot fast spin echo 
 
During acquisition, it is noticed that the T wave of the cardiac cycle is elevated. What is this artifact called? 
 
A. Magnetohydrodynamic Effect 
B. Excitation 
C. Teratogenesis 
D. Magnetophosphenes - correct answer A. Magnetohyrdodynamic Effect 
 
When can heatin...
-
MRSO 2 EXAM Test Questions And Revised Correct Answers
- Exam (elaborations) • 22 pages • 2024
-
Available in package deal
-
- $11.34
- + learn more
MRSO 2 EXAM 
Test Questions And Revised 
Correct Answers 
What group issued the ACR white paper MRI safety? 
a. Food and drug association. 
b. OSHA 
c. EPA 
d. American college of radiology blue ribbon panel on MR safety. - 
ANSWER : d. American college of radiology blue ribbon panel on 
MR safety. 
This individual must have an in-depth understanding of the risks 
associated with the MRI environment? 
a. level 1 personnel 
b. level 2 personnel 
c. non-MR personnel 
d. the patient - ANSWER : ...
-
MRSO Mock Test 1|Questions and Answers, 100% Correct| 2024
- Exam (elaborations) • 29 pages • 2024
- Available in package deal
-
- $17.99
- + learn more
MRSO Mock Test 1|Questions and Answers, 100% Correct| 2024 
What pulse sequence will produce the most patient heating? 
A. Inverse recovery sequence 
B. Single shot fast spin echo 
C. Conventional spin echo 
D. Gradient Echo 
B. Single shot fast spin echo 
During acquisition, it is noticed that the T wave of the cardiac cycle is elevated. 
What is this artifact called? 
A. Magnetohydrodynamic Effect 
B. Excitation 
C. Teratogenesis 
D. Magnetophosphenes 
A. Magnetohyrdodynamic Effect 
When can ...
And that's how you make extra money
-
MRSO Mock Test 2 |Question and Answers| 100% Correct
- Exam (elaborations) • 33 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
MRSO Mock Test 2 |Question and 
Answers| 100% Correct 
An object that produces a weak attractive force in the presence of a strong magnetic field is 
called what? 
A. Paramagnetic 
B. Superparamagnetic 
C. Ferromagnetic 
D. Diamagnetic *Ans* A. Paramagnetic 
What is the risks associated with translational force? 
A. Proximity Heating 
B. Missile effect 
C. Peripheral nerve stimulation 
D. Antenna effect *Ans* B. Missile effect 
Which of the following is measured in milliseconds? 
A. The rise t...
-
MRSO 2024 Test Questions & Correct Revised Answers
- Exam (elaborations) • 13 pages • 2024
-
- $11.99
- + learn more
MRSO 2024 Test Questions & Correct Revised Answers 
 
In which ways an a patient self regulate their temperature when they overheat? - Answer -Evaporation, Radiation 
 
Which of the following statements are true when discussing MR safety 
Larger patients will heat up most 
Smaller patients heat up most 
Larger patients are ferromagnetic 
Induction only occurs in smaller patients - Answer -Larger patients will heat up the most 
 
Which of the following personnel can enter zone 3 and 4 but can't...
-
MRSO - Implants and Devices - Module 5 Test Review |Question and Answers| 100% Correct
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $9.49
- + learn more
MRSO - Implants and Devices - Module 5 
Test Review |Question and Answers| 
100% Correct 
MR screening should be *Ans* -verbal and interactive 
-performed by Level 2 MR Personnel 
MR screening should not be *Ans* simplified 
Who defines terms for marking medical devices in MR environment? *Ans* ASTM 
According to ASTM, MR Safe is applied to items that: *Ans* Items that pose no known 
hazard in ANY MR environment 
Ex: wood, glass, plastic 
According to ASTM, MR Unsafe is applied to items that: *...
-
MAGNETIC RESONANCE SAFETY OFFICER (MRSO) MOCK TEST 1
- Exam (elaborations) • 26 pages • 2023
-
- $11.00
- + learn more
MAGNETIC RESONANCE SAFETY OFFICER (MRSO) MOCK TEST 1 
What pulse sequence will produce the most patient heating? A. Inverse recovery sequence 
B. Single shot fast spin echo 
C. Conventional spin echo 
D. Gradient Echo: Correct answer B. Single shot fast spin echo 
2. During acquisition, it is noticed that the T wave of the cardiac cycle is elevated. What is this artifact called? 
A. Magnetohydrodynamic Effect 
B. Excitation 
C. Teratogenesis 
D. Magnetophosphenes: Correct answer A. Magnetohyrdod...
-
MRSO - RADIO FREQUENCY - MODULE 4 Test Review |Question and Answers| 100% Correct
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
MRSO - RADIO FREQUENCY - MODULE 
4 Test Review |Question and Answers| 
100% Correct 
Purpose of RF (B1) field *Ans* excite hydrogen protons 
RF energy is absorbed by tissues *Ans* within the volume of the RF transmit coil. This is a 
thermogenic process. 
Thermogenic process *Ans* Results in production of heat. Ex: RF energy absorption 
MRI local and whole-body tissue heating is due to *Ans* magnetic induction 
Types of RF coil designs *Ans* -linearly polarized 
-circularly polarized (quadratu...
Did you know that on average a seller on Stuvia earns $82 per month selling study resources? Hmm, hint, hint. Discover all about earning on Stuvia