Master Electrical REAL Exam Questions And Correct Answers | Verified
- Exam (elaborations) • 33 pages • 2023
- Available in package deal
-
- $12.99
- + learn more
Master Electrical REAL Exam Questions And 
Correct Answers | Verified 
Control the speed of the motor - ANSWER The purpose of having a 
rheostat in the field of a DC shunt motor is to ________. 
An ammeter, a wattmeter, and a voltmeter - ANSWER You are to check 
the power factor of a load, you cannot get a power factor meter, you would 
use__________. 
Lead sheath - ANSWER High voltage cable which is to be installed in 
underground ducts is generally protected with a __________. 
Lower watt...
-
NYC Master Electrical Exam PREP TEST QUESTIONS AND ANSWERS 100% | VERIFIED
- Exam (elaborations) • 41 pages • 2024
-
- $14.99
- + learn more
NYC Master Electrical Exam PREP TEST 
QUESTIONS AND ANSWERS 100% | 
VERIFIED 
On a four wire Delta connected system with a midpoint of one phase 
winding is grounded, only the conductor or bus bar having a higher phase 
voltage the ground shall be durably and permanently marked by an outer 
finish that is _______ in color or by other effective means. Such 
Identification shall be placed at each point on the system where connection 
is made if the grounded conductor is also present. - ANSW...
-
NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.
- Exam (elaborations) • 15 pages • 2023
-
- $13.99
- + learn more
NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS. 
 
Type ____ is multiconductor cable identified for use as underground service entrance cable. 
Type USE cable 
Knife switch rated for more than 1200 Amps at 250Volts or less 
Can be used only as isolating switch, shall not be opened under load 
Track lighting with outlets in a bathroom is not allowed because ? 
Track lighting has receptacle 
Where internal combustion engines are used as the prime motor, an on si...
-
Master Electrical Closed Book Exam Questions and verified correct answers
- Exam (elaborations) • 35 pages • 2024
-
Available in package deal
-
- $14.99
- + learn more
XC - correct answer ______ is the letter(s) used to indicate capacitive reactance in a circuit. 
 
A) XL, B) Z, C) HZ, D) XC 
 
Conductors drawn from a copper-clad aluminum rod with the copper metallurgically bonded to an aluminum core. The copper forms a minimum of ________ percent of the csa. - correct answer 10 
 
Relay contacts are made of ___________. - correct answer Silver 
 
Defined apparatus - correct answer The organization or system used for doing or operating something 
 
Operation o...
-
NYC Master Electrical Exam Questions & Answers 100% Correct!!
- Exam (elaborations) • 38 pages • 2024
-
- $13.49
- + learn more
______ shall be permitted to be concealed within walls, floors and ceilings were the walls, floors and ceilings provide a thermal barrier material which has at least one hour finish reading as identified in listing of fire rated assemblies. - ANSWERENT 
 
_____________ motors are permitted as controllers. - ANSWERPortable 
 
________________ shall clearly indicate whether they are in the open off or closed on the position where circuit breaker handles are Operated vertically rather than rotation...
As you read this, a fellow student has made another $4.70
-
NYC Master Electrical Exam 2024 Questions and Answers 100% Correct
- Exam (elaborations) • 32 pages • 2024
-
- $11.99
- + learn more
neutral point - ANSWER-The common point on a wye-connection in a polyphase system or midpoint on a single phase, 3-wire system, or midpoint of a single phase portion of a 3-phase delta system, or a midpoint of a 3-wire, direct current system 
 
In the NEC the words ___________indicate a mandatory requirement - ANSWER-Shall or shall not 
 
On a four wire Delta connected system with a midpoint of one phase winding is grounded, only the conductor or bus bar having a higher phase voltage the ground ...
-
NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS.
- Exam (elaborations) • 15 pages • 2024
-
- $14.49
- + learn more
NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS. 
 
Type ____ is multiconductor cable identified for use as underground service entrance cable. 
Type USE cable 
Knife switch rated for more than 1200 Amps at 250Volts or less 
Can be used only as isolating switch, shall not be opened under load 
Track lighting with outlets in a bathroom is not allowed because ? 
Track lighting has receptacle 
Where internal combustion engines are used as the prime motor, an on si...
-
NYC Master Electrical Exam 2024 Questions and Answers 100% Correct!
- Exam (elaborations) • 32 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
neutral point - ANSWER-The common point on a wye-connection in a polyphase system or midpoint on a single phase, 3-wire system, or midpoint of a single phase portion of a 3-phase delta system, or a midpoint of a 3-wire, direct current system 
 
In the NEC the words ___________indicate a mandatory requirement - ANSWER-Shall or shall not 
 
On a four wire Delta connected system with a midpoint of one phase winding is grounded, only the conductor or bus bar having a higher phase voltage the ground ...
-
NYC Master Electrical Exam PREP TEST QUESTIONS AND ANSWERS 100% | VERIFIED
- Exam (elaborations) • 41 pages • 2023
-
Available in package deal
-
- $15.99
- + learn more
NYC Master Electrical Exam PREP TEST 
QUESTIONS AND ANSWERS 100% | 
VERIFIED 
On a four wire Delta connected system with a midpoint of one phase 
winding is grounded, only the conductor or bus bar having a higher phase 
voltage the ground shall be durably and permanently marked by an outer 
finish that is _______ in color or by other effective means. Such 
Identification shall be placed at each point on the system where connection 
is made if the grounded conductor is also present. - ANSW...
-
NYC Master Electrical Exam STUDY GUIDE ANSWERED
- Exam (elaborations) • 33 pages • 2023
-
- $11.99
- + learn more
neutral point - CORRECT ANSWER The common point on a wye-connection in a polyphase system or midpoint on a single phase, 3-wire system, or midpoint of a single phase portion of a 3-phase delta system, or a midpoint of a 3-wire, direct current system 
In the NEC the words ___________indicate a mandatory requirement - CORRECT ANSWER Shall or shall not 
On a four wire Delta connected system with a midpoint of one phase winding is grounded, only the conductor or bus bar having a higher phase volta...