Journeyman electrician 4 - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Journeyman electrician 4? On this page you'll find 165 study documents about Journeyman electrician 4.

Page 2 out of 165 results

Sort by

Journeyman Electrician 4 Exam Questions with Correct Answers
  • Journeyman Electrician 4 Exam Questions with Correct Answers

  • Exam (elaborations) • 6 pages • 2024
  • Journeyman Electrician 4 Exam Questions with Correct Answers Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits including their end fittings, shall not rise more than _____ above the bottom of the enclosure. a) 6 inches b) 4 inches c) 2 inches d) 3 inches - Answer-D: 3 inches Ref: 408.5 When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected _____. a)on the line side of the service disconnect overcurr...
    (0)
  • $9.49
  • + learn more
Journeyman Electrician #4 Exam Questions and Answers 100% Solved
  • Journeyman Electrician #4 Exam Questions and Answers 100% Solved

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • Journeyman Electrician #4 Exam Questions and Answers 100% Solved Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits including their end fittings, shall not rise more than _____ above the bottom of the enclosure. a) 6 inches b) 4 inches c) 2 inches d) 3 inches - answerD: 3 inches Ref: 408.5 When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected _____. a)on the line side of the service disconnect overcurr...
    (0)
  • $11.49
  • + learn more
Journeyman Electrician #4 Exam Questions and Answers 100% Solved
  • Journeyman Electrician #4 Exam Questions and Answers 100% Solved

  • Exam (elaborations) • 8 pages • 2024
  • Available in package deal
  • Journeyman Electrician #4 Exam Questions and Answers 100% Solved Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits including their end fittings, shall not rise more than _____ above the bottom of the enclosure. a) 6 inches b) 4 inches c) 2 inches d) 3 inches - answerD: 3 inches Ref: 408.5 When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected _____. a)on the line side of the service disconnect overcurr...
    (0)
  • $11.49
  • + learn more
Journeyman Electrician Practice Test | Questions with 100% Correct Answers | Latest Update 2024 | Verified
  • Journeyman Electrician Practice Test | Questions with 100% Correct Answers | Latest Update 2024 | Verified

  • Exam (elaborations) • 17 pages • 2024
  • Journeyman Electrician Practice Test | Questions with 100% Correct Answers | Latest Update 2024 | Verified Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, sin...
    (0)
  • $9.99
  • + learn more
Journeyman Electrician Exam Prep | Questions with 100% Correct Answers | Latest Update 2024 | Verified
  • Journeyman Electrician Exam Prep | Questions with 100% Correct Answers | Latest Update 2024 | Verified

  • Exam (elaborations) • 13 pages • 2024
  • Journeyman Electrician Exam Prep | Questions with 100% Correct Answers | Latest Update 2024 | Verified What table sizes bonding jumpers for for AC systems? - 250.102(C)(1) The NEC defines continuous load to be a load where max current on the circuit continues for at least how many hours? - Three To use the adjustment factors in table 310.15(B)(3)(A), you must have greater than how many current carrying conductors in a raceway? - Greater than three Where in the NEC codebook would you find E...
    (0)
  • $9.99
  • + learn more
Journeyman Electrician #4 Exam Questions and Answers
  • Journeyman Electrician #4 Exam Questions and Answers

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • Journeyman Electrician #4 Exam Questions and Answers
    (0)
  • $10.49
  • + learn more
Journeyman Electrician Practice Test Latest Update Graded A+
  • Journeyman Electrician Practice Test Latest Update Graded A+

  • Exam (elaborations) • 20 pages • 2024
  • Available in package deal
  • Journeyman Electrician Practice Test Latest Update Graded A+ Conductors with _____ marked on the insulation are NOT approved for use in a wet location. THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, single-phase, electrical system from the local utility ...
    (0)
  • $9.99
  • + learn more
Journeyman Electrician Questions and Answers with Verified Solutions
  • Journeyman Electrician Questions and Answers with Verified Solutions

  • Exam (elaborations) • 19 pages • 2024
  • Available in package deal
  • Journeyman Electrician Questions and Answers with Verified Solutions For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service equipment? 50 feet The ampacity of a conductor is defined by the NEC to be the maximum current, in amperes, a conductor can carry continuously under the conditions of use without exceeding ______? ...
    (0)
  • $9.99
  • + learn more
Journeyman Electrician CH #4 Assessment Test Questions and Answers
  • Journeyman Electrician CH #4 Assessment Test Questions and Answers

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • Journeyman Electrician CH #4 Assessment Test Questions and Answers Class 3 single-conductors shall NOT be smaller than _____. a) 18 AWG b) 16 AWG c) 14 AWG d) 20 AWG - Answer-A: 18 AWG Ref: 725.179(H) Given: an office building has a 208Y/120 volt, three-phase service with a balanced net computed load of 90 kVA. What is the current each ungrounded conductor carries at full load? a) 188 amperes b) 250 amperes c) 433 amperes d) 750 amperes - Answer-B: 250 amperes Ref: Trade an...
    (0)
  • $11.49
  • + learn more
Journeyman Electrician Exam 1 - Q & A
  • Journeyman Electrician Exam 1 - Q & A

  • Exam (elaborations) • 6 pages • 2024
  • Journeyman Electrician Exam 1 - Q & A When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box. a) six b) four c) eight d) twelve Ref: 314.28(A)(1) In general, all of the following wiring methods listed are permitted to be used as a feeder for temporary wiring on a construction site EXCEPT _____. a) NM cable b) NMC cable c)...
    (0)
  • $10.49
  • + learn more