Michigan Journeyman Test | 2023 | 75 Questions with 100% Correct Answers | Updated & Verified
- Exam (elaborations) • 10 pages • 2023
- Available in package deal
-
- $12.49
- 1x sold
- + learn more
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 
70 amp load using THHM conductors. The minimum size conductors used our 
#_________AWG - 4 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 
3 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 
TW. Each circuit consist of two phase conductors and one grounding conductor and one 
equipment grounding conduct...
-
BICSI Practice Test exam 2023 with 100% correct answers
- Exam (elaborations) • 11 pages • 2023
-
Available in package deal
-
- $16.49
- 1x sold
- + learn more
The 2 main considerations concerning the existing cabling are? - correct answer Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a - correct answer rolling cut 11-28 
 
Which practice involves moving the customer to a temporary office space until their section of the retrofit is completed and then moving them back to their recabled office space? - correct answer Swing space phasing 
 
Whic...
-
Solar Photovoltaics (PV) Installation Exam | Questions & Answers (Rated A+)
- Exam (elaborations) • 8 pages • 2023
-
Available in package deal
-
- $7.99
- 3x sold
- + learn more
Solar Photovoltaics (PV) Installation Exam | Questions & Answers (Rated A+) 
Solar Photovoltaics (PV) Installation Exam | Questions & Answers (Rated A+) 
 
What is the definition of photovoltaics (PV)? - ANSWER - the science of turning sunlight directly into electricity 
 
What does the abbreviation "PV" stand for? - ANSWER - Photons of light and Volts of electricity (photovoltaic) 
 
What do PV modules consist of? What are these typically made of? - ANSWER - solar cells; silicon 
 
What is si...
-
Michigan Journeyman test exam 2023 with 100% correct answers
- Exam (elaborations) • 7 pages • 2023
-
Available in package deal
-
- $13.49
- 1x sold
- + learn more
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG correct answers4 
 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures correct answers3 
 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and one eq...
-
TFM12 Test with 100% Correct Answers REVISED & VERIFIED 2023//2024
- Exam (elaborations) • 6 pages • 2023
-
Available in package deal
-
- $9.99
- 3x sold
- + learn more
TFM12 Test with 
100% Correct Answers 
REVISED & VERIFIED 
2023//2024 
What is used to protect transformers or other devices supplied from power-supply 
conductors? - ANSWER A. An overcurrent device not rated over 20 Amperes. 
What does PLFA stand for? - ANSWER Power Limited Fire Alarm 
What does NPLFA stand for? - ANSWER Non-Power Limited Fire Alarm 
What material must NPLFA circuit conductors be made from? - ANSWER Solid or 
stranded copper 
What is a single station detector? - ANSWER Batt...
Want to regain your expenses?
-
Michigan Journeyman test | 2023/24 questions and answers
- Exam (elaborations) • 4 pages • 2023
- Available in package deal
-
- $9.49
- 1x sold
- + learn more
Michigan Journeyman test | 2023/24 questions and answers 
 
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 3 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and on...
-
Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits Quiz
- Exam (elaborations) • 2 pages • 2022
-
- $5.99
- 7x sold
- + learn more
Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits Quiz_ 2022. 
According to the NEC®, the ampacity of branch circuit conductors must be derated when there are more than how many current-carrying conductors in a raceway? 
 
Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or the branch circuit selection current (whichever is greater)? 
 
Conductors must be derated when installed in conduit 
 
Continuous load...
-
Fire Alarm TFM12 Questions And Answers
- Exam (elaborations) • 7 pages • 2023
-
Available in package deal
-
- $10.99
- 1x sold
- + learn more
What does PLFA stand for? - Answer- Power Limited Fire Alarm 
 
What does NPLFA stand for? - Answer- Non Power Limited Fire Alarm 
 
What material must NPLFA circuit conductors be made from - Answer- Only solid or stranded copper is permitted 
 
What is a single station detector? - Answer- Battery powered smoke detectors that do not communicate off premises. 
 
What is a multiple station detector? - Answer- Mains powered smoke detectors with battery backup that are linked together, so that if on...
-
ABYC Marine Electrical Certification Exam Review Correct 100%
- Exam (elaborations) • 37 pages • 2023
-
Available in package deal
-
- $11.99
- 1x sold
- + learn more
circuit breaker mean? 
a. The breaker is inexpensive 
b. The breaker will have lots of nuisance trips 
c. The breaker will trip out regardless of conditions 
d. The breaker will only trip at 150% of its rated amperage 
 
b. 8 amps (E-11 Table XII Conductor Ampacity - Flexible Cords) - ANSWER maximum current carrying capacity for an flexible cord of 16 AWG with 2 current carrying conductors inside the engine spaces is 
a. 6 amps 
b. 8 amps 
c. 10 amps 
d. 20 amps 
 
c. only in one direction - ANS...
-
Load calculation Feeders and services Level 4 Module 1 Questions with 100% Correct Answers | Latest Version 2024 | Verified
- Exam (elaborations) • 4 pages • 2024
-
- $8.81
- 1x sold
- + learn more
Load calculation Feeders and services Level 
4 Module 1 Questions with 100% Correct 
Answers | Latest Version 2024 | Verified 
What is the demand factor allowed by the NEC® for calculating the neutral conductor size for electric 
range load? - 70% 
 
Using the VA/linear foot method, the total VA that must be used in a service calculation for a 50' show 
window is - 12,500VA 
 
Before it is considered a continuous load, a load must operate for at least how many hours without 
interruption? - 3 ...