Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien
logo-home
Samenvatting Neural networks - deel 1 €10,49   Ajouter au panier

Resume

Samenvatting Neural networks - deel 1

 4 vues  0 fois vendu

Vak Neurological Aspects, deel 1 van Neural Networks, gegeven door Prof. Alaerts (KUL). Deel 2 (gegeven door Prof. Gilat) is ook beschikbaar.

Aperçu 4 sur 51  pages

  • 2 novembre 2024
  • 51
  • 2023/2024
  • Resume
Tous les documents sur ce sujet (2)
avatar-seller
LB2001
NEUROLOGICAL ASPECTS:
NEURAL NETWORKS AND
REORGANIZATION
Academiejaar 2023-2024 – 2MARE




H1. NEUROSCIENTIFIC METHODS

H2. THE POTENTIAL OF NON-INVASIVE BRAIN
STIMULATION IN NEUROREHABILITATION

H3. AGEING AND NEUROPLASTICITY

H4. NEUROREHABILITATION AFTER STROKE




PART PROF. KAAT ALAERTS

, PART KAAT ALAERTS




Neurological aspects: neural networks
and reorganization
CHAPTER 1: NEUROSCIENTIFIC METHODS


• Measuring ‘brain activity’ at the systems level (not single-cell)
• Non-invasive (not ‘inside’ the brain, but at the level of the scull)
• Fundamental research
o Motor control, motor learning
o Cognition
o Memory
o ...
• Clinical research
o Neural processes underlying ageing
o Neural basis of diseases (stroke, Parkinson, epilepsy, neurodevelopmental disorders)
o Neural evaluation of disease progression
o Neural evaluation of interventions/ treatments

Look for each technique at equipment, neurophysiological basis and examples of applications




 Important concept to evaluate the advantages and disadvantages of different techniques
 Temporal and spatial resolution
o Some better for temporal: what is happening in time regarding brain activity?
o TEMPORAL = when in time
o SPATIAL = where in the brain


1/ MAGNETIC RESONANCE IMAGING (MRI)
What isn’t fMRI?
➢ fMRI is not bumpology (claims that bumps on the skull reflected exaggerated functions/traits)
➢ fMRI is not mind-reading
➢ fMRI is not invasive (the skull remains closed)
What is fMRI: a relative, safe, non-invasive technique


1

, PART KAAT ALAERTS




1.1 Equipment
- Giant magnet
- Head coil (helps with high-quality images)

MRI = brain anatomy
fMRI = functional MRI = brain activity
fcMRI = functional connectivity

First MRI-scan around 1950, first functional MRI-scan developed way later (around 1990)

1.2 Biological basis of MRI
• Measures brain anatomy
• Former name: (Nuclear) Magnetic Resonance Imaging → nothing to do with ‘radioactivity’, but
with the magnetic properties of protons, in the nuclei of atoms

Protons:
- Have a mass, are positive (+) and have a spin (they turn around)
- Because protons turn around, they have a small, but measurable magnetic field
- In everyday life, the protons in our body are in balance, randomly oriented, but in balance
- Inside the MRI scanner, which is one giant magnet, the protons align to the magnetic field (B0).
Either in parallel (same direction) or anti-parallel (opposite direction)
- Most protons will align parallel in MRI-scan
- The majority of atoms aligns in parallel, allowing to define the NET magnetization of protons
in the direction of B0
- This is what happens if you’re positioned in the scanner. And this magnetic field is ALWAYS on.




- Emission of a radio frequency pulse by the head coil, induces a flip of the NET magnetization
(instead of aligning to the Z- axis, the protons now align in the X-Y field)
- Proton is in excitation state
- Head coils will emit a radiofrequency: magnetic field of protons will shift (excitation
state) → follow the Y-axis
- However, protons don’t like being in this ‘high-energy’ excitation state’, and from the moment
the radio frequency pulse is turned off, it will ‘relax’ to its initial position (i.e., align back to the
Z-axis of the B0 field).
- During this ‘relaxation state’, the protons emit radio frequency themselves, and this signal is
measured. (The head coil, both emits and measures radio frequencies)
- Proton emits radio frequency during relaxation state
- Protons want to align with the Z-axis → when the radiofrequency is turned off, they
return to the Z-axis
- While doing this, they will emit radiofrequency itself → MRI can measure the different
relaxation times in the different tissue




2

, PART KAAT ALAERTS



The time it takes for a proton to relax to 63% of its initial state (along the z-axis) is called T1
 T1 = relaxation time

• Not all tissues ‘relax’ the same way!
• Protons in fat (e.g., white matter), relax much faster, than protons
in liquid (e.g., cerebrospinal fluid)
• By measuring the relaxation in different tissues, contrasts can be
visualized!
• In so-called ‘T1-weighted’ images, liquid is dark (less energy emitted), and fat is bright (more
energy emitted) → dark matter needs less energy at T1 compared to white matter (grey matter
is in between)
1.2.1 Examples of application
➢ Clinical: Localization of brain lesions
➢ Used in pre-surgical mapping (e.g., epilepsy) and prediction of disease progression




1.3 Functional MRI (fMRI)
 Uses MRI to indirectly measure brain activity

Same principle as MRI: contrasts in brain images based on measurement of magnetic relaxation
→ Here however, it is not about protons, but about hemoglobin in the blood...
1.3.1 Biological basis of fMRI
• Brain region active => increased O2 metabolism => increased blood flow
• fMRI measures the Blood Oxygen Level Dependent (BOLD) signal
o Oxyhemoglobin = diamagnetic (same as tissue)
o Deoxyhemoglobin = paramagnetic (weak magnetic) → interacts with the signal of MRI
• fMRI always measures a change in BOLD-response
o You always need a baseline to see how BOLD has changed
o During baseline situation, the BOLD-signal goes back down again

LEFT-LEFT = brain at rest
 Basic metabolism (good balance between oxy and de-oxy Hb in bloodstream, normal usage of
oxygen by the neuronal cells, normal glucoses dosage as energy resource)
LEFT-RIGHT = activation of the neuron
→ Neurons will require an increased metabolism of glucoses and oxygen
 Initially in bloodstream will be higher amount of de-oxy compared to oxy
→ This gives a reduced BOLD-signal
RIGHT = this triggers a haemodynamic respons rendering an increased transport of oxy to this region
of activation
 Rendering in a lowering of the ratio de-oxy/oxy → rendering in an increase of BOLD-signals



3

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur LB2001. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €10,49. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

80364 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€10,49
  • (0)
  Ajouter