_________ are necessary for complete combustion - Accurate Answers time, temperature, mixture, and atomization If the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - Accurate Answers 214.7 A boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and cl...

[Montrer plus]

Aperçu 4 sur 32  pages

  • 22 octobre 2024
  • 32
  • 2024/2025
  • Examen
  • Questions et réponses
  • 3RD CLASS STATIONARY STEAM ENGINEER LICENSE
  • 3RD CLASS STATIONARY STEAM ENGINEER LICENSE
avatar-seller
3RD CLASS STATIONARY STEAM
ENGINEER LICENSE TEST
3RD CLASS STATIONARY STEAM ENGINEER LICENSE TEST WITH GUARANTEED
ACCURATE ANSWERS




_________ are necessary for complete combustion - Accurate
Answers✔✔✔ time, temperature, mixture, and atomization


If the steam pressure gauge indicates 200 PSIG, the absolute pressure
is______ - Accurate Answers✔✔✔ 214.7


A boiler is operating at 400 PSI, and the safety valve opens at 410 PSI
and closes at 398 PSI. The blowdown is______ psi - Accurate
Answers✔✔✔ 12

,An oil cooler is commonly used with a(n) ________ when operating in
conjunction with a turbo-generator - Accurate Answers✔✔✔ steam
turbine


A boiler is producing 40,000lb of steam/hr at a pressure of 100 PSI and a
steam temperature of 500 degrees Fahrenheit. The steam produced is
_______ steam - Accurate Answers✔✔✔ superheated


The economizer on a boiler is used to _______ - Accurate
Answers✔✔✔ add heat to the feed water


Blowers are normally used with________ boilers - Accurate
Answers✔✔✔ water tube


Overheating of tubes on a boiler can be caused by________ - Accurate
Answers✔✔✔ scale on tubes


Carbon dioxide in a condensate return system causes_________ -
Accurate Answers✔✔✔ channeling


A ________ pump is a positive displacement pump - Accurate
Answers✔✔✔ reciprocating


A boiler generating 6000 lb of steam/hr produces _______btu/hr -
Accurate Answers✔✔✔ 6,000,000

,A bottom blowdown is performed on a boiler to _____ - Accurate
Answers✔✔✔ discharge sludge and sediment


Water columns are connected to the boiler with a minimum of _______"
pipe - Accurate Answers✔✔✔ 1


The minimum size of a water column blowdown valve is_______". -
Accurate Answers✔✔✔ 3/4


The maximum size bottom blowdown valve on a boiler is_________". -
Accurate Answers✔✔✔ 2 1/2


A ________ allows condensate to pass through, but stops Steam. -
Accurate Answers✔✔✔ a steam trap


When taking over a shift, the first thing to do is check the________ -
Accurate Answers✔✔✔ water level in each boiler


According to the asme code, a high-pressure boiler having more than
500 square feet of heating surface shall have________ - Accurate
Answers✔✔✔ two or more safety valves


The probable cause of an increase in temperature of gases of combustion
at the boiler Outlet is____ - Accurate Answers✔✔✔ dirty heating
services

, Boilers in battery equipped with________ must have two main steam
stop valves and a free-flowing drain between them - Accurate
Answers✔✔✔ manhole openings


In order to be sure the gauge glass is indicating an accurate water level
reading, the stationary engineer should______ - Accurate Answers✔✔✔
blowdown the gauge glass


A continuous blowdown line is located___ - Accurate Answers✔✔✔ in
the Steam and water drum well below the nowl


A temperature reading of 80 degrees Celsius is equal to_________°f -
Accurate Answers✔✔✔ 176


A chimney temperature of 250 degrees Fahrenheit above steam
temperature indicates_______ - Accurate Answers✔✔✔ poor efficiency


A manometer is red in________ - Accurate Answers✔✔✔ inches of
water


The boiling point of water will____ with an increase in pressure -
Accurate Answers✔✔✔ be raised


If a lather is not obtained when performing a soap hardness test, the
water sample is_______ - Accurate Answers✔✔✔ hard

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur GRADEUNITS. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €15,04. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

81177 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€15,04
  • (0)
  Ajouter