Garantie de satisfaction à 100% Disponible immédiatement après paiement En ligne et en PDF Tu n'es attaché à rien
logo-home
Commercial Refrigeration Certification Study Questions with Complete Solutions €11,62   Ajouter au panier

Examen

Commercial Refrigeration Certification Study Questions with Complete Solutions

 8 vues  0 fois vendu
  • Cours
  • Commercial Refrigeration Certification
  • Établissement
  • Commercial Refrigeration Certification

Commercial Refrigeration Certification Study Questions with Complete SolutionsCommercial Refrigeration Certification Study Questions with Complete SolutionsCommercial Refrigeration Certification Study Questions with Complete Solutions Approximately how much Air flow is required across an air coole...

[Montrer plus]

Aperçu 2 sur 11  pages

  • 19 septembre 2024
  • 11
  • 2024/2025
  • Examen
  • Questions et réponses
  • Commercial Refrigeration Certification
  • Commercial Refrigeration Certification
avatar-seller
Commercial Refrigeration
Certification Study Questions with
Complete Solutions
Approximately how much Air flow is required across an air cooled condenser? -
ANSWER - 750-1000 CFM Per Ton of Cooling Capacity


A sling psycrometer is used to measure.....? - ANSWER - Wet and dry bulb
temperature


The capacity of an evaporative condenser depends on....? - ANSWER - The Entering
Air Wet Bulb Temperature


Hot Gas Bypass refers to....? - ANSWER - All of Above (Preventing low suction
pressure, Providing Capacity Control, Preventing Compressor short Cycling.)


A compressor is operating with a discharge pressure of 185.3 PSIG and a suction
pressure of 25.3 PSIG. The compression ratio (Pumping Ratio) is.....? - ANSWER - 5:1


Wet bulb depression is.....? - ANSWER - The difference between Wet bulb and Dry
Bulb Temperatures


A compressor net oil pressure is determined by.....? - ANSWER - Oil pump discharge
pressure minus the Suction Pressure


Some compressors are fitted with an unloading device to provide variable capacity.
Variable Capacity is necessary to......? - ANSWER - All of above (Prevent Undesirably
low evaporator pressures, Prevent evaporator coil frost, & Prevent Compressor short
Cycling)


Refrigerant in the suction line should be slightly superheated in order to.......? -
ANSWER - Insure liquid refrigerant does not enter the Compressor

, A decrease in water flow, when using a water cooled condenser....? - ANSWER -
Increase the power consumtion of the compressor


If a TEV sensing bulb lost its charge, what effect would this moment have on the AC
system? - ANSWER - Both A and B(It would cause high side pressure to increase and
cause low side to decrease)


What is the purpose of the distributor....? - ANSWER - It evenly feeds refrigerant to
the evpaorator


High compressor operating temperatures can be caused by.....? - ANSWER - All of
Above (Low Volumetric Efficiency, Low Suction Pressures, and High Compression
Ratio)


The clearance space in a reciprocating compressor....? - ANSWER - Has an effect on
compressor capacity


The amount of heat absorbed in the evaporator is equal to....? - ANSWER - The heat
in the conditioned space


Approximately how much airflow is required across the evaporator per ton of cooling
capacity? - ANSWER - 350-400 CFM Per Ton


The most reliable and safest method of field charging a system is.....? - ANSWER - To
charge by weight according to manufacturer specifications


On split system installations, the suction line should be pitched towards the
compressor at least....? - ANSWER - One inch per 10 feet (1 inch/10ft)


Polyolester oils---? - ANSWER - All of Above (hold moisture tightly, so more
evacuation time may be necessary, Have similar lubricity and miscibility
characteristics as mineral oil, and Absorb atmospheric moisture more easily than
mineral oil)

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur NursingTutor1. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €11,62. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

80364 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€11,62
  • (0)
  Ajouter