Different tissues that have signals that appear similar on an MR image are described as:
A) hypointense
B) hyperintense
C) isointense
D) isodense - ANSWER-isointense
in a large main magnetic field such as those employed in MRI, the motion of a hydrogen
proton has been described as wobbling like a spinning top. this motion is called
A) precession
B) resonance
C) frequency
D) angular momentum - ANSWER-precession
magnetic resonance imaging is derived from the process known as: A) magnetic resonance angiography
B) magnetic relaxation imaging
C) nuclear magnetic resonance
D) nuclear resonance imaging - ANSWER-nuclear magnetic resonance
Once the nmv has moved away from equilibrium, the following will occur
A) the longitudinal component will increase
B) the transverse component will decrease
C) the longitudinal component will stay the same D) the transverse component will increase - ANSWER-the transverse component will increase
In MR, substances respond to a specific radio frequency which is known as:
A) magnetic frequency
B) radio frequency
C) gyro-magnetic frequency
D) resonance frequency - ANSWER-resonance frequency
the introduction of gadolinium based contrast enhancement agents by intra-venous injection can involve passing through an abnormal blood brain barrier. the tissue compartments involved are the:
A) intravascular to interstitial
B) extracellular to intracellular C) hepatobiliary to renal
D) extradural to renal - ANSWER-intravascular to interstitial
t2 is the measurement of time fot the transverse component of the NMV to decrease what percentage of its maximum value after the application of a 90 degree radio-
frequency pulse
A) 33%
B) 63%
C) 37%
D) 67% - ANSWER-37%
in the USA, the MRI system's magnetic field and vector that represents it is symbolized:
A) B1
B) B2
C) B3
D) B0 - ANSWER-B0
The resonance frequency of any substance in a magnetic field can be calculated by employing the A) damadian equation
B) larmor equation
C) faraday equation
D) lauterbur equation - ANSWER-Larmor equation
in a pulse sequence, transmitting an initial 90 degree radio-frequency pulse will cause the NMV to:
A) remain at equilibrium B) shift in both size and direction
C) move to antiparallel
D) rephase - ANSWER-shift in both size and direction
Which type of electromagnetic coils are designed to stimulate and detect an MR signal?
A) gradient coils
B) radio-frequency coils
C) shim coils - ANSWER-radio-frequency
tissues that are less efficient at spin-spin interactions because they contain more free water, such as CSF, should have
A) High T2 values and produce hypointense signals
B) HIgh T2 values and produce hyperintense signals
C) low T2 values and produce hypointnese signals D) low T2 values and produce hyperintense signal - ANSWER-High T2 values and produce hyperintense signals
magnetism can be defined as the ability of certain substances to attract:
A) Copper, aluminum, tin B) Iron, cobalt, nickel
C) Bronze, niobium, titanium
D) Neodymium, niobium-titanium, lodestone - ANSWER-Iron, cobalt, nickel
the purpose of magnetic resonance angiography is to image the:
A) stationary soft tissue
B) blood flow
C) vessel lumen
D) only abnormal vessels - ANSWER-blood flow
the strength of very large magnetic fields like those employed in MRI systems, the SI unit most commonly used is:
A) Tesla
B) Gauss
C) Kilogauss
D) militesla - ANSWER-Tesla
the larmor frequency of hydrogen protons in a 1.5 tesla magnetic field is: A) 6.4 MHZ/Tesla
B) 12.8 MHz/Tesla
C) 25.5 MHz/tesla
D) 63.9 MHz/tesla - ANSWER-63.9 MHz/Tesla
In MR imaging, for chemical substance to be affected by the main magnetic field and the radio-wave it must contain an:
A) Odd number of electrons
B) Odd number of total protons and neutrons
C) Even number of total electrons and neutrons
D) even number of protons - ANSWER-Odd number of total protons and neutrons
A 1.5T magnetic field is equal to:
A) 150 gauss
B) 1500 gauss
C) 15,000 gauss
D) 150,000 gauss - ANSWER-15,000 gauss
the components of the gyromagnetic ratio are:
A) stimulation to relaxation
B) protons to electrons
C) magnetic moment to angular momentum
D) main magnetic field to radio-frequency signal - ANSWER-magnetic moment to angular momentum
fast transition phenomenon and entry phenomenon are theories that explain which of the following characterisitics:
A) T1 effects B) T2 effects
C) hydrogen concentration D) veolcity effects - ANSWER-Velocity effects
the effects of main magnetic field inhomogeneities on the FID signal are corrected for in the spin echo sequence by applying a second radio frequency pulse. the flip angle of this radio frequency pulse is:
A) 45 degrees
B) 60 degrees C) 90 degrees D) 180 degrees - ANSWER-180 degrees
of the following statements, which describes part of the basic MR imaging process:
A) a patient is placed isocenter to ionizing radiation
B) the patient is exposed to ionizing radiation
C) the generated image contains hypersense and hypodense areas
D) radio frequency signals interact with hydrogen protons - ANSWER-radio frequency signals interact with hydrogen protons
which type of electromagnetic coils correct inhomogeneities in the main magnetic field?
A) gradient coils
B) radio frequency coils
C) shim coils - ANSWER-shim coils
immediately after an initial 90 degree radio frequency pulse is turned off, the hydrogen protons will begin to:
A) Rephase
B) Dephase
C) Stay in the transverse plane
D) Stay in phase - ANSWER-Dephase
tissues that are very efficient at spin-lattice interactions near the larmor frequency, such as fatty tissues should have:
A) Low T1 values and produce hyperintense signals
B) High T1 values and produce hyperintense signals
C) High T1 values and produce hypointense signals
D) Low T1 values and produce hypointense signals - ANSWER-Low T1 values and produce hyperintense signals
T1 is the measurement of time for the longitudinal component of the NMV to recover what percentage of its original value after the application of a 90 degree radio frequency
pulse?
A) 33%
B) 63%
C) 37%
D) 67% - ANSWER-63%

Les avantages d'acheter des résumés chez Stuvia:

Qualité garantie par les avis des clients

Qualité garantie par les avis des clients

Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.

L’achat facile et rapide

L’achat facile et rapide

Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.

Focus sur l’essentiel

Focus sur l’essentiel

Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.

Foire aux questions

Qu'est-ce que j'obtiens en achetant ce document ?

Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.

Garantie de remboursement : comment ça marche ?

Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.

Auprès de qui est-ce que j'achète ce résumé ?

Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur NursingTutor1. Stuvia facilite les paiements au vendeur.

Est-ce que j'aurai un abonnement?

Non, vous n'achetez ce résumé que pour €12,60. Vous n'êtes lié à rien après votre achat.

Peut-on faire confiance à Stuvia ?

4.6 étoiles sur Google & Trustpilot (+1000 avis)

80364 résumés ont été vendus ces 30 derniers jours

Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans

Commencez à vendre!
€12,60  2x  vendu
  • (0)
  Ajouter