Mechanical transducer - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Mechanical transducer? On this page you'll find 834 study documents about Mechanical transducer.
Page 2 out of 834 results
Sort by
-
ARDMS- SPI Comprehensive Exam (2023/24) || Questions & 100% Correct Solutions
- Exam (elaborations) • 36 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
ARDMS- SPI Comprehensive Exam (2023/24) || Questions & 100% Correct Solutions 
ARDMS- SPI Comprehensive Exam (2023/24) || Questions & 100% Correct Solutions 
 
 
Mechanical transducer image shape: - ANSWER - fan or sector-shaped 
 
Mechanical transducers have a _________ focal depth. - ANSWER - fixed 
 
When there is any damage done to the crystal in a mechanical transducer, - ANSWER - the entire image is lost 
 
Array transducers are comprised of... - ANSWER - a single slab of PZT cut into ...
-
CCI: Physics of Ultrasound-URR Questions With Answers Graded A+ Assured Success
- Exam (elaborations) • 23 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
Frequencies used in transthoracic imaging are usually in the range of ____________. Frequencies used in 
transesophageal imaging are usually in the range of ______________. 
A) 3-6 MHz;6-8 MHz 
B) 3-6 MHz; 5-7 MHz 
C) 2.5-4 MHz; 5-7 MHz 
D) 1-3 MHz; 6-8 MHz - 2.5-4 MHz; 5-7 MHz 
Which of the following will aid in visualization of the endocardium? 
A) Increased transducer frequency 
B) Larger sector size 
C) Increased wall filter 
D) Agitated saline contrast - Increased transducer frequency-this ...
-
SPI ULTRASOUND REGISTRY REVIEW Questions and Answers (100% Pass)
- Exam (elaborations) • 24 pages • 2024
-
- $13.49
- + learn more
SPL 
 wavelength x # of cycles 
With phased array transducers, the transmitted sound beam is steered by 
 Varying the timing of pulses to the individual piezoelectric elements 
What type of wave is sound? 
 mechanical and longitudinal 
The Frequency ranges for Ultrasound are: 
 > 20,000 Hz (20kHz) 
The speed of sound in soft tissue is: 
 1540 m/s 
Linear sequence Array 
Master01 |Excellent Study Material| Latest update 
1 | P a g e | © copyright Master01| Grade A+ 
 transducer that fires the...
-
CEFM Practice Test| Answered 100% Correctly| Updated 2024-2025
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $20.49
- + learn more
CEFM Practice Test| Answered 100% Correctly| Updated 
The paper speed used with EFM in North America is: 
a. 1cm/min 
b. 2cm/min 
c. 3cm/min 
C. 3cm/min 
The US transducer on the EFM measures the 
a. Electrical signal of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
c. R to R intervals of the fetal heart 
b. Mechanical movement of the fetal heart reflected off of sound waves 
The purpose of the autocorrelation in external monitoring is to 
a. Compare i...
-
SPI ULTRASOUND REGISTRY REVIEW EXAM QUESTIONS & ANSWERS SCORED A+
- Exam (elaborations) • 9 pages • 2024
- Available in package deal
-
- $8.39
- + learn more
The layer of material within the transducer which has an intermediate impedance 
between the transducer element and the human tissue in known as the: - 
️️matching layer 
Huygen's Principle - ️️states that waves are the result of the interference of many 
wavelets produced at the face of the transducer 
What happened to intensity if the amplitude of a signal is halve? - ️️Quarted/ 
Intensity is proportional to the amplitude squared, so if the amplitude is halved, the 
resulting in...
Fear of missing out? Then don’t!
-
CEFM Practice Test Questions & Answers | with 100% Correct Answers | Updated & Verified
- Exam (elaborations) • 28 pages • 2024
-
- $12.99
- + learn more
1.	The paper speed used with EFM in North America is: 
a.	1cm/min 
b.	2cm/min 
c.	3cm/min 
ANS : c. 3cm/min 
2.	The US transducer on the EFM measures the 
a.	Electrical signal of the fetal heart 
b.	Mechanical movement of the fetal heart reflected off of sound waves 
c.	R to R intervals of the fetal heart 
ANS : b. Mechanical movement of the fetal heart reflected off of sound waves 
3.	The purpose of the autocorrelation in external monitoring is to 
a.	Compare incoming waveforms for comparison 
...
-
Davies Breast Sonography Review ARDMS Exam Study Guide Questions and Answers 2024
- Exam (elaborations) • 42 pages • 2024
- Available in package deal
-
- $15.49
- + learn more
Which artifact may cause structures to look deeper than they actually are? 
A. Side lobe 
 B. Shadowing 
 C. Refraction 
 D. Propagation speed error 
E. Slice thickness -Correct Answer D. propagation speed error 
 
The optimum operating frequency for a broad-bandwidth transducer would 
be: 
A. 6 MHz 
 B. 7 MHz 
C. 8 MHz 
D. 9 MHz 
E. 10 MHz -Correct Answer C. 8 
 
In breast sonography, which of the following is NOT significantly affected by the limited field of view when imaging superficia...
-
ASVAB MEPS Exam 223 Questions with Verified Answers,100% CORRECT
- Exam (elaborations) • 24 pages • 2023
-
- $12.99
- 2x sold
- + learn more
ASVAB MEPS Exam 223 Questions with Verified Answers 
 
A radar is designed to report the track of an aircraft every second. If this radar reports 30 tracks in one minute, what percentage of the time did the radar track the aircraft? - CORRECT ANSWER 50% 
 
Jerry walked a dog from 6:40 a.m. to 7:30 a.m. one day. If he was paid at the rate of $6 per hour, how much did he earn that day? - CORRECT ANSWER $5.00 
 
A woman is looking for a bigger square office. She finds an office twice the area of he...
-
URR mock exam 1 SPI Questions And Answers Rated A+
- Exam (elaborations) • 26 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
The doppler shift is 5000 Hz. The pulse repetition frequency is 9000 Hz. Which of the 
following is true? 
A. peak pressure gradient is 36mmHg 
B. range ambiguity will occur 
C. aliasing will occur 
D. the peak velocity is equal to 2 m/s - ️️C. aliasing will occur 
When evaluating a suspected arterial stenosis, a doppler angel of ____ degrees will 
produce the most accurate flow velocity. 
A. 0 
B. 30 
C. 60 
D. 90 - ️️A. 0 
Spatial resolution is: 
A. the minimum reflector separation req...
-
DMS Physics review Questions With Complete Solutions
- Exam (elaborations) • 49 pages • 2023
-
- $15.99
- + learn more
Waves are classified according to whether or not they need a medium in which to propagate. A wave which needs a medium is called a(n) ______________________ wave, a wave which will propagate in a vacuum (the absence of a medium) is called a(n) ________________ wave correct answer: mechanical, electromagnetic 
 
What are the two classifications of mechanical waves? correct answer: Transverse and longitudinal 
 
Frequency has the units of: (select all that apply) 
A. Cycles/second 
B. Hz 
C. Her...
Do you wonder why so many students wear nice clothes, have money to spare and enjoy tons of free time? Well, they sell on Stuvia! Imagine your study notes being downloaded a dozen times for $15 each. Every. Single. Day. Discover all about earning on Stuvia