100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
Previously searched by you
OHLO LEAD ABATEMENT CONTRACTOR TEST EXAM QUESTIONS AND CORRECT ANSWERS| ACCURATE REAL EXAM WITH FREQUENTLY TESTED QUESTIONS AND RATIONALE|ALREADY A GRADED|GUARANTEED PASS|LATEST UPDATE 2024/2025$24.89
Add to cart
OHLO LEAD ABATEMENT CONTRACTOR TEST EXAM QUESTIONS AND CORRECT ANSWERS| ACCURATE REAL EXAM WITH FREQUENTLY TESTED QUESTIONS AND RATIONALE|ALREADY A GRADED|GUARANTEED PASS|LATEST UPDATE 2024/2025
1 view 0 purchase
Course
OHLO LEAD ABATEMENT CONTRACTOR
Institution
OHLO LEAD ABATEMENT CONTRACTOR
OHLO LEAD ABATEMENT CONTRACTOR TEST EXAM
QUESTIONS AND CORRECT ANSWERS| ACCURATE REAL
EXAM WITH FREQUENTLY TESTED QUESTIONS AND
RATIONALE|ALREADY A GRADED|GUARANTEED
PASS|LATEST UPDATE 2024/2025OHLO LEAD ABATEMENT CONTRACTOR TEST EXAM
QUESTIONS AND CORRECT ANSWERS| ACCURATE REAL
EXAM WI...
OHLO LEAD ABATEMENT CONTRACTOR TEST EXAM
QUESTIONS AND CORRECT ANSWERS| ACCURATE REAL
EXAM WITH FREQUENTLY TESTED QUESTIONS AND
RATIONALE|ALREADY A GRADED|GUARANTEED
PASS|LATEST UPDATE 2024/2025.
"Competent Person for health and safety" as defined by OSHA - CORRECT ANSWER A
person who can identify hazards
Someone who can take corrective action
OSHA respirator protection standards relevant to lead abatement work - CORRECT ANSWER
When above the permissible exposure limit:
Need to wear HEPA filter and any other appropriate filter
Have a written respiratory program in place
OSHA general industry standards relevant to lead abatement work - CORRECT ANSWER
Similar to the construction rule except: it pertains to exposure to lead when it is not
Construction
Agriculture
Factory manufacturing
Medical removal is different
Return to work level is different
Describe blood monitoring requirements - CORRECT ANSWER If air monitoring is above the
action level
30ug/m3 for more than 30 days/year
Every 2 months for the first 6 months
If above 40ug/dl then back to every 2 months
At 50ug/dl- medical removal (if 2 consecutive tests)
,Recognize the correct wording of lead wording signs - CORRECT ANSWER DANGER: Lead
work area
May Damage Fertility or the Unborn Child, Cause Damage to the Central Nervous System, Do
Not Eat, Drink, or Smoke in this Area
Describe the OSHA construction standards (other than lead regs) - CORRECT ANSWER -Fall
protection
-Eye protection
-Hazard Communication
-Anything having to do with worker protection and construction (including asbestos)
Describe the general requirements specified by the OSHA construction standards - CORRECT
ANSWER -Train your people
-Monitor the air they're breathing (PEL is 50ug/m3, AL is 30ug/m3)
-Take steps to reduce exposure to lead
-Do blood monitoring
Keep adequate records
Describe the exposure monitoring and written compliance plan requirements specified by the
OSHA lead in construction standards - CORRECT ANSWER -Depending on what Class work it
is, assume a certain exposure of lead
-Adjust respirator after finding out what exposure is
-Document what type of work is being done
-Exposure below AL (30ug/m3) is considered negative assessment. not repeated until job
conditions change
-If exposure is above PEL (50ug/m3) monitor every 3 months
-between 30-50ug/m3, monitor every 6 months
-written compliance plan
Exposure assessment schedule when assessment reports levels below AL (30ug/m3) -
CORRECT ANSWER Not repeated until job conditions change
,Exposure assessment schedule if exposure is above PEL (50ug/m3) - CORRECT ANSWER
Every 3 months
Exposure assessment schedule if exposure is between AL (30ug/m3) and PEL (50ug/m3) -
CORRECT ANSWER Every 6 months
OSHA hazard communication standards (HAZCOM) relevent to Lead Abatement work -
CORRECT ANSWER -Train workers about hazards they're working with and how to respond
appropriately
-label containers
-Distribute MSDS
OSHA Action Level for lead - CORRECT ANSWER 30ug/m3
OSHA Permissible exposure level for lead - CORRECT ANSWER 50ug/m3
How often do lead abatement supervisors need to take a refresher course? - CORRECT
ANSWER Every 2 years
The units used to express lead levels in air - CORRECT ANSWER ug/m3
The units used to express lead levels in soil - CORRECT ANSWER ppm
The units used to express lead levels in dust - CORRECT ANSWER ug/sq ft.
HUD and EPA post-abatement clearance standards for lead in dust - CORRECT ANSWER
Floor= 40 ug/ft2
Sill= 250 ug/ft2
Well= 400 ug/ft2
Describe the purpose and focus of the HUD guidelines - CORRECT ANSWER - Provide
guidance for federally assisted housing
- It has become a standard for the industry
, Why is it important to ensure that worker certification cards and certificates are current? -
CORRECT ANSWER - So they don't have to take the full course again
- So that the supervisor doesn't get fined for having people with expired cards on site
Wisconsin DHS 163 certification requirements for lead worker - CORRECT ANSWER Lead
safe renovator class
Lead abatement work class
Submit application and fee to DHS
WI DHS 163 certification requirements for supervisor - CORRECT ANSWER - 1 day lead safe
renovator class
- One day lead abatement work class and related experience
- 2 yrs construction experience or 1 yr as lead worker
- 2 day lead abatement supervisor class
- Submit application and fee to WI DHS
- Pass state exam
WI DHS 163 definition of abatement - CORRECT ANSWER Activity designed to permanently
eliminate lead based paint hazards
WI DHS 163 definition of lead based paint - CORRECT ANSWER - 0.5% lead by weight
- more than 1.0 mg/cm2
Notification requirements for lead abatement or lead hazard reduction activities - CORRECT
ANSWER - Not less than 2 days before project starts
- Notify if there is a change in date within one working day of the original start date
- Emergency notification by phone, but DHS has to receive notice in writing within 24 hrs.
Which WI regulation covers lead training and certification - CORRECT ANSWER DHS 163
DHS 163 definition of interim control activity - CORRECT ANSWER - A measure designed to
temporarily reduce human exposure to a lead-based paint hazard
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller DrMedinaReed. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $24.89. You're not tied to anything after your purchase.