Which artifact may cause structures to look deeper than they actually are?
A. Side lobe
B. Shadowing
C. Refraction
D. Propagation speed error
E. Slice thickness - ANSWER D. propagation speed error

The optimum operating frequency for a broad-bandwidth transducer would
be:
A. 6 MHz
B. 7 MHz
C. 8 MHz
D. 9 MHz
E. 10 MHz - ANSWER C. 8

In breast sonography, which of the following is NOT significantly affected by the limited
field of view when imaging superficial structures?
A. Contrast resolution
B. Spatial resolution
C. Axial resolution
D. Lateral resolution
E. Temporal resolution - ANSWER E. temporal resolution

Which of the following affects the actual intensity of the sound utilized for imaging?
A. TGC
B. Output power
C. Overall gain
D. Dynamic range
E. Harmonics - ANSWER B. output power

The dynamic range of a display is the:
A, Number of gray shades
B. Depth of focal zone
C. Intensity of sound utilized
D. Image scale
E. Output power - ANSWER A. number of gray shades

,6.
Using color/power Doppler while a patient hums to better delineate a mass is called:
A. Aliasing
B. Spectral mirroring
C. Ring-down
D. Harmonics
E. Fremitus - ANSWER E. fremitus

7. A standoff pad thicker than 1 cm is NOT recommended because it will:
A. Make the skin line look thicker than normal.
B. Affect the optimal placement of the fixed elevation plane focus.
C. Compress the mammary layer and make it look fibrotic.
D. Cause enhancement of echoes in the mammary zone.
E. Cause decreased penetration and an inability to see the chest wall. - ANSWER B.
affect the optimal placement of the fixed elevation plane focus

Which type of transducer does NOT allow the sonographer to vary the focusing
capabilities?
A. Electronic linear array
B. Electronic convex array
C. Annular array
D. Mechanical sector
E. Electronic sector - ANSWER D. mechanical sector

9. When taking patient history for a breast sonogram, what information from a
previous mammogram would NOT be considered relevant?
A. Symmetry of breasts
B. Location of a questionable lesion
C. Size of a questionable lesion
D. Date and results of a previous mammogram
E. Name of the radiographer - ANSWER E. Name of radiologist

10. Image amplitude is affected by:
A. Power
B. Overall gain
C. Time gain compensation (TGC)
D. A and B
E. A, B, and C - ANSWER E. Power, TGC, Overall gain

11. High-frequency transducers used in breast imaging provide excellent
resolution of breast tissues but limited:
A. Focusing options
B. Gain adjustment
C. Penetration
D. Gray scale

,E. Scan lines - ANSWER C. penetration

2. When using the 123-ABC method of annotation, "B" would indicate:
A. Mass is close to the nipple.
B. Mass is medium shade of gray
C. Mass is in the mammary zone.
D. Mass is benign.
E. Mass requires biopsy. - ANSWER C. mass is in the mammary zone

13. In the 123-ABC method of annotation, the numbers denote the:
A. Distance from nipple
B. Depth of the mass
C. Number of masses
D. Stage of cancer
E. Sequence of imaging - ANSWER A. distance from nipple

14. Which method of patient positioning is best for evaluating the medial aspect of the
breast?
A. Posterior oblique
B. Lateral decubitus
C. Upright
D.Trendelenburg
E. Supine - ANSWER E. supine

15. The two-handed technique is used to image:
A. Both breasts at the same time
B. An extremely large breast
C. The main breast duct and nipple
D. Multiple masses within the breast
E. A palpable mass that is mobile - ANSWER C. the main breast duct and the nipple

16. Which of the following transducers would be the best choice for breast
imaging?
A. 5 MHz phased array
B. 3.5-5 MHz curved linear array
C. 8 MHz annular array
D. 10 MHz linear array
E. 12 MHz mechanical sector - ANSWER D. 10 MHz linear array

17. Selecting multiple focal zones will:
A. Decrease frame rate
B. Increase frame rate
C. Decrease frequency
D. Increase frequency
E. Increase penetration - ANSWER A. decrease the frame rate

, 18. When viewing a mammogram, one always sees the marker in the region
toward the:
A. Axilla
B. Nipple
C. Medial breast
D. Top of the film
E. Bottom of the film - ANSWER A. axilla

19. If a breast sonographic image is labeled Rt. AR 2:00 1A, the area described
is:
A. In the right axillary region, upper outer quadrant, just under the skin
B. Radial scan of the right breast, upper outer quadrant, mid breast
C. Radial scan of the right breast, upper inner quadrant, near the chest wall
D. Antiradial scan of the right breast, upper inner quadrant near the nipple,
under the skin
E. Antiradial scan of the right breast, lower inner quadrant, under the skin,
near the areola - ANSWER D.

20. When viewing a mammogram, a mass is marked near the CC marker in the
right breast. This will indicate to the sonographer that the mass is located:
A. In the lower outer quadrant
B. In the medial breast
C. In the lateral breast
D. In the upper outer quadrant
E. Near the nipple - ANSWER C. in the lateral breast

**the mamm marker CC is always placed near the axilla, which is lateral to the breast;
therefore, the mass would be more located toward the lateral aspect of the breast

A transducer that can operate at multiple frequencies is said to have:
A. Broad bandwidth
B. Variable focus
C. Harmonics
D. Multiple transmit zones
E. Dynamic range - ANSWER A. broad bandwidth

All of the following statements about high-frequency transducers are true
EXCEPT:
A. Axial resolution is increased
B. Lateral resolution is increased
C. Sound travels faster
D. Sound penetration is decreased
E. Best for breast imaging - ANSWER C. sound travels faster

Decreasing depth will:
A. Increase the frequency of sound used

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller leonardmuriithi061. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart