100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS. Exam Questions With Correct Answers $12.49   Add to cart

Exam (elaborations)

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS. Exam Questions With Correct Answers

 0 view  0 purchase
  • Course
  • Sprinkler
  • Institution
  • Sprinkler

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS. Exam Questions With Correct Answers. Fire department connection - answernormally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furn...

[Show more]

Preview 3 out of 27  pages

  • November 12, 2024
  • 27
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Sprinkler
  • Sprinkler
avatar-seller
Thebright
©THEBRIGHT EXAM SOLUTIONS

11/05/2024 12:06 PM


S12 sprinkler test, S13 standpipe test,
Sprinklers segment 5, S-12 CITYWIDE
SPRINKLER SYSTEMS. Exam Questions
With Correct Answers.


Fire department connection - answer✔normally on exterior of building... FDNY can pump supplemental
water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to
supplement existing water supplies.

system control valve - answer✔valve controlling flow to water-based fire protection systems.

fire command center - answer✔Designated room or area in a structure where the status of the fire
detection, alarm, and protection systems is displayed and the systems can be manually controlled.

Fire pump, automatic standpipe. - answer✔A fire pump located at or below street level that supplies the
lower 300 feet (91.4 m) of a standpipe system or a combined standpipe and sprinkler system.

tags - answer✔on closed section valves serving affected areas: area affected, brief description,
occupancy classification, c of f number, estimated time until operational

Green tag - answer✔no impairment found in entire system- main control valve

red tag - answer✔place on main control valve if FULLY out of service... put sprinkler company name,
date of removal from service and anticipated time to operational

blue disk - answer✔partially out of service- on all fire department connections

water storage tank - answer✔Collects cooled water

OS & Y valve - answer✔indicating type of control valve used for fire sprinkler system

deluge valve - answer✔water supply control valve intended to be operated by actuation of an automatic
detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL
AND AUTO

deluge sprinkler system - answer✔employing open sprinklers that are attached to a piping system that is
connected to a water supply through a valve that is opened by the operation of a detection system

, ©THEBRIGHT EXAM SOLUTIONS

11/05/2024 12:06 PM

installed in the same areas as the sprinklers. WHEN IT OPENS, water flows into the piping system and
discharges from all sprinklers attached.

Early suppresion fast response sprinklers - answer✔fast response sprinkler that is listed for its capability
to provide fire suppression of specific high challenge fire hazards

extra large orifice sprinklers - answer✔= or > 1 inch less pressure to achieve a given discharge density

extended coverage sprinkler - answer✔400 max square feet discharge 20 foot by 20 foot spacing
between sprinklers

fire pump - answer✔a provider of liquid flow and pressure dedicated to fire protection. A fire pump is a
part of a fire sprinklers system water supply and can be powered by electric, diesel or steam. connected
to public water source or tank. provides higher pressure to sprinkler system

Glass bulb sprinkler - answer✔operated by heat breaking a glass bulb filled with a non freezing liquid
with diameters that vary form 3 mm for quick response to 5 mm for standard response

hose valve - answer✔valve to additional hose connection

hydraulic placard - answer✔sign attached to a hydraulically calculated sprinkler system indicating the
design density, required gallons per minute and pressure for the system to operate properly

hydraulically calculated systems - answer✔method of sizing auto sprinkler piping using a prescribed
amount of water to be distributed over a specific area.

impairment coordinator - answer✔in charge of safety during out of service systems

intermediate level sprinkler - answer✔sprinkler equipped with integral shields to protect the operating
elemtn form discharge from sprinklers installed at higher elevations

large orifice sprinkler - answer✔sprinkler head with orifice size equal or greater than 3/4 and less than 1
inch

listed device - answer✔A fire protection component that has been tested to perform under parameters
specified for its use by a nationally recognized testing agency. Underwriter's Laboratory (UL) and Factory
Mutual (FM) are the two most common.

Master Pressure Reducing Valve - answer✔A pressure reducing valve installed to regulate pressures in
an entire fire protection system and/or standpipe system zone.

Main Drain - answer✔The primary drain connection located on the system riser and also utilized as a
flow test connection.

Microbiologically Influenced Corrosion (MIC) - answer✔Corrosion caused by the presence of microbes in
the water supply that over time attack the interior of metallic piping and cause leaks, pitting, and
blockages.

, ©THEBRIGHT EXAM SOLUTIONS

11/05/2024 12:06 PM

Old-Style/Conventional Sprinkler - answer✔A sprinkler that directs 40% to 60% of the water initially in a
downward direction and is designed to be installed with the deflector in either the upright or pendent
position.

Pendent Sprinkler - answer✔A sprinkler designed to be installed in such a way that the water stream is
directed downward against the deflector.

Pintle Screws - answer✔A visual indicating device required for sprinklers manufactured prior to 1999
identifying small orifice sprinklers and large orifice sprinklers where orifice size is different than the
nominal thread size of the sprinkler head.

Pipe Schedule Systems - answer✔A method of sizing piping based upon the number of sprinkler heads
and the occupancy of the protected area.

Preaction Sprinkler System - answer✔A sprinkler system employing automatic sprinklers that are
attached to a piping system that contains air that may or may not be under pressure, with a
supplemental detection system installed in the same areas as the sprinklers.

Pressure Control Valve - answer✔A pilot operated pressure reducing valve that may be used with a fire
or booster pump designed for the purpose of preventing the incoming water supply pressure from
dropping below a set pressure.

Pressure-Reducing Valve - answer✔A valve designed for the purpose of reducing the downstream water
pressure under both flowing (residual) and nonflowing (static) conditions.

Pressure Relief Valve - answer✔A valve designed for the purpose of releasing excess air or water
pressure from the Fire Protection Piping System.

Pressure Tank - answer✔A tank using air pressure to supplying water for water-based fire protection
systems. Tank contents to be maintained at one third air to two thirds water.

Quick Response Sprinkler Head - answer✔A sprinkler having a fusible link with a response time index
(RTI) of 50 or less.

Recessed Sprinkler - answer✔A sprinkler in which all or part of the body, other than the shank thread, is
mounted above the ceiling.

Residential Sprinkler - answer✔A type of fast response sprinkler that has been specifically tested to
enhance survivability in the room of fire origin and listed for use in dwelling units.

Response Time Index (RTI) - answer✔A measurement of the thermal sensitivity of a sprinkler head
expressed in (meters-seconds) 1/2.

Supervisory signal - answer✔A signal indicating the need for action or the use of such device in
connection with the supervision of fire alarm systems or the maintenance features of related systems.

Small orifice sprinklers - answer✔A sprinkler head with and orifice size smaller than 1⁄2"

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Thebright. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79373 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart