100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
EPA SECTION 608 TYPE III (2024 revision) $11.99   Add to cart

Exam (elaborations)

EPA SECTION 608 TYPE III (2024 revision)

 0 view  0 purchase
  • Course
  • EPA SECTION 608 TYPE III
  • Institution
  • EPA SECTION 608 TYPE III

Identify the pressure corresponding to 32F for R-123 - answer20 inches of Hg vacuum Refrigerant is added to a centrifugal machine through the - answerevaporator charging valve What precaution should be taken prior to recovering refrigerant from a chiller suspected of having tube leaks? - answ...

[Show more]

Preview 2 out of 15  pages

  • November 11, 2024
  • 15
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • EPA SECTION 608 TYPE III
  • EPA SECTION 608 TYPE III
avatar-seller
TOPDOCTOR
EPA SECTION 608 TYPE III (2024 revision)
Identify the pressure corresponding to 32F for R-123 - answer20 inches of Hg vacuum

Refrigerant is added to a centrifugal machine through the - answerevaporator charging valve

What precaution should be taken prior to recovering refrigerant from a chiller suspected of having tube
leaks? - answerdrain the water sides of the evaporator and condenser

Where does refrigerant go after it leaves the purge unit of a low pressure centrifugal system - answerthe
evaporator

A charged low pressure refrigeration system can be efficiently leak checked by - answerraising system
pressure by heating with circulated hot water or heating blankets

To determine how much vapor to charge into an evacuated chiller, you should charge with vapor until -
answerthe system pressure corresponds to a refrigerant saturation temperature of 36F

After recovering the liquid refrigerant you must - answerrecover the vapor refrigerant

A rupture disc on a recovery vessel for low pressure refrigerants relieves at - answer15 psig

The discharge from a rupture disc should be piped - answeroutdoors for venting

According to the EPA, there is approximately ________ refrigerant vapor left in an average 350 ton R-11
chiller at 0 psig pressure once all the R-11 liquid has been removed? - answer100 lbs

When there is excessive moisture collecting in the purge unit of a low pressure refrigeration system, this
indicates that the - answercondenser or chiller barrel tubes are leaking

R-11 at a pressure of 17 inches Hg vacuum has a saturation temperature of - answer35f

The maximum test pressure for leak testing a low pressure centrifugal is - answer10 psig

R-11 at 14.7 PSIA will boil at about - answer74.5F

According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above
_______ during a standing vacuum test, the system should be checked for leaks. - answer2.5 mm Hg

If you suspect a leak in the water box of a chiller, you should place the leak detector probe
_____________, and sniff for refrigerants. - answerthrough a drain valve

The purge unit takes its suction from the - answertop of the condenser

When installing more than one, pressure relief valves must be installed;

A.) In series with each other.

, B.) In parallel with each other.

C.) In the system's suction line.

D.) On top of compressor head. - answerc.) In parallel with each other

In a low-pressure chiller, air and other non-condensables collect at the;

A.) Bottom of the compressor

B.) Top section of the condenser

C.) Bottom fo the evaporator

D.) Header before the metering device. - answerb.) Top section of the condenser

Because a low-pressure system operates below atmospheric pressure (in a vacuum),

A.) The system is unlikely to have air and moisture enter the system.

B.) Leaks in gaskets or fittings will cause air and moisture to enter the system.

C.) Leaks in the gaskets or fittings will cause substantial refrigerant leaks.

D.) Leaks in the gaskets or fittings will cause oil clogging at the condenser. - answerb.) Leaks in gaskets or
fittings will cause air and moisture to enter the system.

Where is the purge unit located in a low-pressure system?

A.) The top of the condenser

B.) In the lowest location.

C.) Above the shell.

D.) Before the oil operator. - answera.) The top of the condenser

When LEAK TESTING a low-pressure chiller, the maximum pressure to use is;

A.) 5 psig

B.) 10 psig

C.) 15 psig

D.) 20 psig - answerb.) 10 psig

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TOPDOCTOR. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81989 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.99
  • (0)
  Add to cart