OIL BURNER LICENSE EXAM 2024| 250 ACTUAL EXAM
QUESTIONS AND 100% CORRECT ANSWERS| GRADED A+
What is the first thing a tech should do when arriving at a no combustion call? - CORRECT ANS✔✔ Ask
how many times the customer reset the unit.
What is the best long term solution for preventing a clogged nozzle? - CORRECT ANS✔✔ -Remove any
underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.
Hot water and steam valves are interchangeable. - CORRECT ANS✔✔
False
When in the presence of a flame, a cad cell normally reads.. - CORRECT ANS✔✔ 300-1000 ohms
If a pump is used to bring oil to a level higher than the tank, an oil safety valve is required. - CORRECT
ANS✔✔ True
On a call where a hydronic heat system is putting out too much heat on the stack, the issue may be.. -
CORRECT ANS✔✔ -Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.
A high CO2 reading is caused by.. - CORRECT ANS✔✔ Incomplete combustion
An often overlooked cause of a high CO2 reading is.. - CORRECT ANS✔✔ Not enough combustion air in
the equipment room.
When multiple pumps are wired together in a heating system, they should be wired in.. - CORRECT
,ANS✔✔ parallel
In a series circuit.. - CORRECT ANS✔✔ Current has one path.
When 2 burners are connected to the same chimney.. - CORRECT ANS✔✔ Sufficient draft must be
obtained to operate both units.
The ignition transformer is located.. - CORRECT ANS✔✔ In the primary control.
When safeties are wired in series one safety will affect the operation of the others. - CORRECT ANS✔✔
True
A stack switch is no longer allowed to be installed or replaced because.. - CORRECT ANS✔✔ It's safety
cutout time is higher than what is now required.
What is a power venter and what does it do? - CORRECT ANS✔✔ An electrical device that sends fluid
gases into the chimney connector.
A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening for
combustion air? - CORRECT ANS✔✔ 140"
The difference between an adjustable flame retention burner and a fixed flame retention burner is? -
CORRECT ANS✔✔ Air inlets can be adjusted
Ignitor position can be adjusted
Fuel can be adjusted
,Oil tank design, construction, installation and testing shall be in accordance with.. - CORRECT ANS✔✔
527 CMR 9.0
Heat is a form of.. - CORRECT ANS✔✔ Energy
If a burner is operational but the circulator pump isn't running.. - CORRECT ANS✔✔ The pump relay is
not working correctly
A method of dealing with low viscosity/cold temps with #2 oil? - CORRECT ANS✔✔ Increase pump
pressure/ decrease nozzle size
What is needed at the outlet of an oil tank? - CORRECT ANS✔✔ Thermal safety
valve
Where do you obtain an installation permit for oil burners? - CORRECT ANS✔✔
Fire Dept
How many Btu's approximately in 1 gal of #2 fuel oil? - CORRECT ANS✔✔
140,000 btu's
Solid state ignition is superior to spark because - CORRECT ANS✔✔ It is not affected by reduced voltage
What is an installation? - CORRECT ANS✔✔ The complete setting in place, ready for operation, of an
oil burner appliance together with its accessories and equipment.
How far must a power vent terminate from an opening or window? - CORRECT
ANS✔✔ 4' A pump in a one pipe system that is full of air can be self purged. -
CORRECT ANS✔✔ False List the minimum size of an oil supply line. - CORRECT
ANS✔✔ 3/8"
, A material with electrons so loose it allows voltage to pass with little or no resistance.. - CORRECT
ANS✔✔ Is a conductor
If a high limit goes off, what does a low water switch do? - CORRECT ANS✔✔ Maintains water
temperature
What is flashpoint an indicator of? - CORRECT ANS✔✔ Minimum temperature oil will ignite but not
continue to burn.
What travels on the inside of the wire? - CORRECT ANS✔✔ Volts
What does readily accessible mean pertaining to oil burning equipment? - CORRECT ANS✔✔ Capable
of being reached easily and quickly for operation, maintenance or inspection.
What is the minimum vent pipe on an oil tank? - CORRECT ANS✔✔ 1 1/4"
What causes corrosion on a flue pipe? - CORRECT ANS✔✔ When the flue pipe is operating below the
dew point temperature.
What are the methods to prevent oil waxing? - CORRECT ANS✔✔ Put additives in the fuel.
Add an oil line heater.
Cut with #1 fuel or kerosene.
What is the maximum tank size allowed inside unenclosed? - CORRECT ANS✔✔ 660 gal
What is the purpose of a delayed oil valve? - CORRECT ANS✔✔ Allows time for the oil pump to get up to
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller TopNursingSolution. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $15.49. You're not tied to anything after your purchase.