Which three locations are slip joint connections allowed? ✔✔Trap seal, Trap outlet, Trap inlet
(IPC 405.9)
What is the minimum waste connection for an eye wash station? ✔✔None required (IPC 411.2)
The occupant load for seasonal outdoor seating and entertainment areas shall not be included when
determining the minimum number of facilities required. T/F ✔✔False (IPC 403.1)
Where a toilet room is provided for the use of multiple occupants, the egress door for the room shall
be lockable from the inside of the room. T/F ✔✔False (IPC 403.3.6)
Water closet bowls for public or employee toilet facilities shall be of the elongated type. T/F
✔✔True (IPC 425.2)
A water heater pan may be installed without any connection to a drain. T/F ✔✔True (IPC 504.7.1)
There shall be a check valve or shutoff valve between a relief valve and the heater or tank served. T/F
✔✔False. (IPC 504.4.1) Shall NOT be a check valve
The drain valve on a water heater shall be provided with female garden hose threads. T/F ✔✔False.
(IPC 501.3) Shall be "male garden hose threads."
Temperature and Pressure Relief Valve discharge pipe may be smaller than the outlet of the
device served. T/F ✔✔False (IPC 504.6)
, Which device is provided to relieve excess pressure on a water heater? ✔✔temperature and pressure
relief valve (IPC 504.4)
The pan shall be not less than _______ in depth. ✔✔1 1/2" (IPC 504.7.1)
What is the maximum temperature for a Temperature and Pressure Relief Valve? ✔✔210
degrees Fahrenheit (IPC 504.5)
Where a storage tank-type water heater or a hot water storage tank is installed in a location where water
leakage from the tank will cause ___________, the tank shall be installed in a pan. ✔✔damage
(IPC 504.7)
The pan drain shall extend full size . . .and terminate not less than _____ inches and not more than
_____ inches above the adjacent ground surface. ✔✔6, 24 (IPC 504.7.1)
Water heaters and storage tanks shall be located and connected so as to provide ready access
for observation, maintenance, servicing and replacement. T/F ✔✔False
The method of connecting a circulating water heater to the tank shall provide proper ________ of water
through the water heater. ✔✔circulation (IPC 503.2)
All water heaters should be provided with a 30" x 30" access for inspection, service, repair
and replacement. T/F ✔✔True (IPC 502.5)
Unfired hot water storage tanks shall be insulated to what R-factor? ✔✔12.5 (IPC 505.1)
Temperature and Pressure Relief Valve discharge pipe must be trapped. T/F ✔✔False (IPC 504.6) not be
trapped.
Where a combination potable water heating and space heating system requires water for space heating
at temperatures greater than _______, a master thermostatic mixing valve . . . shall be provided to limit
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Examsplug. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $13.00. You're not tied to anything after your purchase.