100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
NHIE_ Electrical System — Exam QuestionsCOMPLETE SOLUTIONS GRADED A+ $8.99   Add to cart

Exam (elaborations)

NHIE_ Electrical System — Exam QuestionsCOMPLETE SOLUTIONS GRADED A+

 2 views  0 purchase
  • Course
  • MS or M.S. - Master of Science
  • Institution
  • MS Or M.S. - Master Of Science

NHIE_ Electrical System — Exam QuestionsCOMPLETE SOLUTIONS GRADED A+

Preview 2 out of 8  pages

  • November 1, 2024
  • 8
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • MS or M.S. - Master of Science
  • MS or M.S. - Master of Science
avatar-seller
mbitheeunice2015
11/2/24, 12:44 AM NHIE: Electrical System — Exam Questions Flashcards | Quizlet



NHIE: Electrical System — Exam Questions COMPLETE
SOLUTIONS GRADED A+
Terms in this set (96)


Service entrance conductors run from the - True
service drop to the service box or service
panel. True of false?

The service size is determined by the - True
amperage and the voltage ratings of the
service.

Is the service drop overhead or - Overhead
underground?

Are service laterals overhead or - Underground
underground?

The drip loop is typically part of the service - False
drop. True or False?

The wire size for the service drop must be - False
the same as the wire size for the service
entrance conductors. True or False?

How many wires would you typically find in -3
a 240-volt service drop?

What would 4 wires mean? - 3-phase electricity

What would 2 wires usually mean? - 120 volt service

1. Overhead wires too low.
2. Damaged or frayed wires.
3. Trees or vines interfering with wires.
List 7 common problems with service
4. Wires too close to doors or windows.
drops.
5. Wires not well-secured to the house.
6. Poor connection between service drop and service entrance.
7. Inadequate clearance from roofs.

Clearances above:
- Roadway 18 ft
- Driveway 12 ft.
List clearances above ground, swimming - Walkway 10 ft.
pools, and roofs. - Flat roof 10 ft.
- Sloped roof (e.g., > 4:12) 18 in.
- Low slope roof (e.g., < 4:12) 3 ft.
- Swimming pool 22.5 ft

The service entrance conductors run from - Service drop to service box
the _________ to the __ _.

All service entrance conductors must be in - False
conduit. True or False?

All service entrance conductors must be - False
attached above roof level. True or False?

The drip loop should be as close to the - False
roof as possible. True or False?

https://quizlet.com/637857009/nhie-electrical-system-exam-questions-flash-cards/ 1/8

, 11/2/24, 12:44 AM NHIE: Electrical System — Exam Questions Flashcards | Quizlet
1. No drip loop
2. No mast head
3. Mast head not weather tight.
4. Mast or conduit bent.
List 10 common problems with service 5. Mast or conduit rusted.
entrance conductors. 6. Mast rotted (if wood).
7. Mast conduit or cable not well secured.
8. Mast conduit or cable not weather tight.
9. Conduit or cable not well sealed at house/wall penetration.
10. Cable frayed, damaged, or covered by siding.

1. conduit joints
2. mast head
List 4 common areas of water penetration
3. roof flashing
into service entrances.
4. meter base
5. house entry

1. Prevents water entry into the conduit or service entrance conductors.
List 2 functions of the drip loop.
2. Shows that the service drop wires are not straining the splices.

Roughly 999 out of 1000 houses have - 240 volts
_ ____ volts available.

Roughly 999 out of 1000 houses have - 3 service entrance wires
_ ____ service entrance wires.

Load calculations are part of a home - False
inspection.

Implications of an undersized service - e.
include:
a. shock hazard
b. fire hazard
c. shock and fire hazard
d. melting insulation
e. nuisance tripping of the main fuses and
breakers

What is the largest single-phase service - 400 amps
that you are likely to find in a home?

What size copper wire would you expect a. 6 gauge
to find on the service entrance for: b. 4 gauge
a. 60-amp service c. 2-0 gauge
b. 100-amp service
c. 200-amp service

Which of the following is a reliable way to - d.
identify the service size?
a. Size of the service drop wires
b. Distribution panel rating
c. Service box rating
d. Service entrance conductor
e. Service entrance conduit size

Aluminum is an acceptable service - True
entrance conductor material. True or
False?

A fused 200-amp service has two 100-amp - False
fuses in the service box. True or False?



https://quizlet.com/637857009/nhie-electrical-system-exam-questions-flash-cards/ 2/8

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller mbitheeunice2015. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $8.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80796 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$8.99
  • (0)
  Add to cart