100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
2024 VA HIC License Exam Prep $9.99   Add to cart

Exam (elaborations)

2024 VA HIC License Exam Prep

 7 views  0 purchase
  • Course
  • Virginia Hic
  • Institution
  • Virginia Hic

2024 VA HIC License Exam Prep Protruding objects may not protrude more than ___ inches into the path of travel. - ANS 4" ANSI Accessible and Usable Buildings and Facilities, 2017 Page 15 In new buildings, thresholds at doorways should be no higher than ______. - ANS ...

[Show more]

Preview 4 out of 36  pages

  • October 29, 2024
  • 36
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Virginia Hic
  • Virginia Hic
avatar-seller
DocLaura
2024 VA HIC License Exam Prep


Protruding objects may not protrude more than ___ inches into the path of travel. - ANS 4"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 15

In new buildings, thresholds at doorways should be no higher than ______. - ANS 1/2"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 30

In a Type A unit, if measuring to the highest part of the rim or highest part of the counter, what is
the maximum height of the sink front above the floor? - ANS 34"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 149

The height of handrails shall be ____ minimum and ____ maximum vertically above stair
nosings, ramp and walking surfaces. - ANS 34" minimum, 38" maximum

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 62

A hallway more than 24 inches long must have a clear width of ____. - ANS 36"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19

Enter and proceed" is presented as a _____ on the raised touchable surface on a function key."
- ANS Circle

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 107

Operable parts shall be operable with one hand and shall not require: - ANS Tight
grasping, pinching, or twisting of the wrist.

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 18

,In existing buildings and facilities, the clear width of a walking surface shall be permitted to be
reduced to ____ minimum for a length of 24 inches maximum. - ANS 32 inches

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19

The clear width of an exterior accessible route located within seating areas shall be ___
minimum. - ANS 36 inches

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19

The running slope of walking surfaces shall not be steeper than: - ANS 1:20

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19

What components shall not be part of an accessible route? - ANS Revolving doors &
Turnstiles

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 19

The maximum height of existing elevator call buttons shall be permitted to be located ___ above
the floor. - ANS 54"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 40

The maximum knee clearance shall be permitted to extend ____ under an element that is 9"
above the floor. - ANS 25"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 13

The brightness of the elevator car landing sill, threshold, platform and controls are to be no less
than _____ foot candles. - ANS 5

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 51

What is the least diameter of grab bars with circular cross sections? - ANS 1-1/4"

,ANSI Accessible and Usable Buildings and Facilities, 2017
Page 87

All hardware such as handles, locks, or any other operable parts shall be ____ minimum above
the floor. - ANS 34"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 32

In new construction, what is the maximum slope of a ramp? - ANS 0.05

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 33

In existing buildings and facilities, the turning space shall be a circular space with a ___
minimum diameter. - ANS 60-inch

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 10

What is the minimum diameter of a circular turnaround area in a new building? - ANS 60"

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 10

Doorways shall have a clear opening width of 32 inches minimum. Projections into the clear
opening width between 34 inches and 80 inches above the floor shall not exceed: - ANS 4
inches

ANSI Accessible and Usable Buildings and Facilities, 2017
Page 25

What is the first step to placing a bifold door? - ANS Install the top track first

Carpentry and Building Construction - Page 616

Glulams are sometimes manufactured with a slight upward curve known as ____? - ANS
Camber

Carpentry and Building Construction - Page 361

When using a splash block to direct water from a down spout, how long should it be to carry
away water from the foundation? - ANS 3'

, Carpentry and Building Construction - Page 653

How many bundles are usually in a square of 3-tab shingles? - ANS 3

Carpentry and Building Construction - Page 637

What would be mixed into a concrete mixture to control the wear resistance and stability of
concrete? - ANS Water

Carpentry and Building Construction - Page 223

What is the typical height of a regular base kitchen cabinet? - ANS 34-1/2"

Carpentry and Building Construction - Page 784

A roll roofing strip should have at least how many inches overlapping at the eave? - ANS
1/4"

Carpentry and Building Construction - Page 629

Of the species commonly used in house construction, the heartwood of bald cypress, redwood,
and various cedars is highest in _______ resistance. - ANS Decay

Carpentry and Building Construction - Page 329

Before concrete is placed, what is commonly used to secure the sides of foundation wall forms
to prevent spreading? - ANS Snap ties

Carpentry and Building Construction - Page 265

On a blueprint, what do lines that end with arrows represent? - ANS Dimension lines

Carpentry and Building Construction - Page 45

Which of the following is not a required material when mixing a concrete batch? - ANS
Calcium chloride

Carpentry and Building Construction - Page 218

What should be placed with every second course when you are building a stack bond pattern
block wall? - ANS Joint reinforcement

Carpentry and Building Construction - Page 276-277

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller DocLaura. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67096 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99
  • (0)
  Add to cart