§ 2635(c)(2). Installation and Testing Requirements for All New Underground
Storage Tanks
(2) The local agency may waive the requirement for overfill prevention equipment
where the tank inlet exists in an observable area, the spill container is adequate
to collect any overfill, and the tank system is filled by transfers of no more than 25
gallons at one time.
What is true about flow restrictors?
A. Flow restrictors on vent piping meet positive shut-off requirements
B. Flow restrictors do not meet positive shut-off requirements prior to Oct 1,
2018.
C. Flow restrictors on vent piping which require repair or replacement on or after
October 1, 2018, shall be retrofitted with overfill prevention equipment
D. Local agency can approve the use of flow restrictors on or after Oct 1, 2018. -
ANSWERS-C. Flow restrictors on vent piping which require repair or replacement
,on or after October 1, 2018, shall be retrofitted with overfill prevention
equipment
§ 2635. Installation and Testing Requirements for All New Underground Storage
Tanks and
§ 2665. Spill Container and Overfill Prevention Equipment Upgrade Requirements
§ 2635 (d) On and after October 1, 2018, flow restrictors on vent piping do not
meet the requirement of subdivision (c) above when overfill prevention
equipment is installed.
§ 2665(c) All overfill prevention equipment which use flow restrictors on vent
piping which require repair or replacement on or after October 1, 2018, shall be
retrofitted with overfill prevention equipment in accordance with sections
2635(c) and (d).
What does not describe how suction piping is designed/constructed?
A) The below-grade piping operates at less than atmospheric pressure
B) Suction piping is continuously monitored
C) No valves or pumps are installed below grade in the suction line. Only one
check valve is located directly below and as close as practical to the suction pump
D) The below-grade piping is sloped so that the contents of the pipe will drain
back into the storage tank if the suction is released - ANSWERS-B) Suction piping
is continuously monitored
By definition an "underground storage tank system" includes
a.) The tank, all connected piping and dispensers
,b.) The tank, all connected piping, ancillary equipment and containment system
c.) Only the tank
d.) Only tanks totally beneath the surface of the ground - ANSWERS-b.) The tank,
all connected piping, ancillary equipment and containment system
(H&SC, Sec 25281(z))
The written report submitted to the local agency after an unauthorized release is
required to include the following except:
a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered - ANSWERS-b.) Cause of the release
CCR Title 23, Sec 2652(c)
Which agency approves a site-specific variance which allows for an alternative
method of construction or monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control
d.) The local agency - ANSWERS-a.) The Regional Water Quality Board
CCR Title 23, Sec 2681(a)
, The regulations to enforce compliance of underground storage tank systems in
the state are found in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17 - ANSWERS-b.) California
Code of Regulations; Title 23, Chapter 16
An unauthorized release which does not escape from secondary containment only
requires a record on the operator's monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection
D. All of the above - ANSWERS-D. All of the above
H&SC, Sec 25294
The annual monitoring certification may be performed by:
A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the monitoring
equipment
C. A designated UST operator
D. A person who meets the requirements of both a and b - ANSWERS-D. A person
who meets the requirements of both a and b
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller NurseLNJ. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $15.99. You're not tied to anything after your purchase.