100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
NCIDQ PRACTICUM EXAM 2024 ACTUAL EXAM COMPLETE 250 QUESTIONS AND CORRECT ANSWERS WITH EXPLANATIONS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!! $18.99   Add to cart

Exam (elaborations)

NCIDQ PRACTICUM EXAM 2024 ACTUAL EXAM COMPLETE 250 QUESTIONS AND CORRECT ANSWERS WITH EXPLANATIONS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!!

 8 views  0 purchase
  • Course
  • NCIDQ PRACTICUM
  • Institution
  • NCIDQ PRACTICUM

NCIDQ PRACTICUM EXAM 2024 ACTUAL EXAM COMPLETE 250 QUESTIONS AND CORRECT ANSWERS WITH EXPLANATIONS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!!

Preview 3 out of 29  pages

  • October 17, 2024
  • 29
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • NCIDQ PRACTICUM
  • NCIDQ PRACTICUM
avatar-seller
Americannursingaassociation
NCIDQ PRACTICUM EXAM 2024 ACTUAL EXAM
COMPLETE 250 QUESTIONS AND CORRECT
ANSWERS WITH EXPLANATIONS (VERIFIED
ANSWERS) |ALREADY GRADED A+||BRAND NEW
VERSION!!




In wet areas, what are the requirements for wall finishes? - ANSWER- walls within 2' or
service sinks, toilets, or urinals are required to be constructed of moisture resistant
material (cement board, X) and are required to have tile (or similar) finish up to
minimum 4' AFF. Wallcovering may be used above 4' AFF. Lavatories do not count as a
service sink.

Are outlets required on every wall? - ANSWERResidential yes, Commercial no

What is the minimum clear floor space in front of a lavatory? - ANSWER30" x 48" with
about 17" of that clear under the lavatory

What is the minimum clear floor space in front of a bathtub? - ANSWER30" x 48"

What is the minimum clear floor space in front of a urinal? - ANSWER30" x 48"

What is the minimum clear floor space in front of a shower? - ANSWER30" x 48"

All front approach (barrier free) counters must have a clear knee space of at least: -
ANSWER30" W x 17"D

All front approach (barrier free) counters must have a clear floor space of: -
ANSWER30" W x 48"D with about 17" of the 48" underneath the counter

(t/f) The dip of the overflow shall not be considered in determining knee and toe
clearances. - ANSWERtrue, you don't count the overflow drain

For the PRAC, this chair is in the way of a credenza. Where do I put the marker(s)? -
ANSWEROn BOTH the chair AND the credenza, they are in the way of each other.

,What are the CLEARANCES required at an accessible toilet/water closet? - ANSWERa
60" turnaround anywhere in the space, have 60" clear at the toilet's rear wall, and 56"
clear along the side wall.

When taking PRAC, are clearances and dimensions the same? - ANSWERNO -
clearances are the dashed shaped boxes and dimensions are the linear strings

When taking PRAC, can you put more than one room label per room when asked to
label spaces per program? - ANSWERNO, one label per room. just because you can fit
2 workstations in an open office, doesn't mean you put the "open office" label in the
room twice.

Which walls are subject to the most glare and heat issues? - ANSWERSouth

Where should emergency lighting be located? - ANSWERAisles, corridors, and exit
access stairways and ramps.

Where should audio/visual fire alarms be located? - ANSWERRestrooms, hallways,
lobbies, and general assembly areas & visible from any location in the room. This
means that sometimes 2 are required if the space is a hallway with a turn. They are
mounted between 6'-8" to 7'-6" AFF.

what do supply diffusers look like in an RCP - ANSWERThey typically have an X
through them

what do return diffusers typically look like in an RCP? - ANSWERThey typically have a
diagonal line through them.

What residential walls need to be framed as plumbing walls? - ANSWERAny wall with
any type of plumbing going through it. Standard residential walls are 2x4 studs and
walls with any pipes going through need to be 2x6.

What residential appliances require a 240V outlet? - ANSWERAppliances with a heating
element like ovens, cooktops and dryers.

How should outlets be placed in a residential kitchen? - ANSWEREach appliance gets
an outlet. Each section of countertop that is wider than 12" gets an outlet. Outlets
shouldn't be closer than 24". An outlet should be placed on either side of the sink. All
outlets in a dwelling serving the countertop will be GFCI.

Per NCIDQ, electrical receptacles located within ________" of a water source must be
_______. - ANSWER......36" of a water source must be GFI.

Name the correct parts of a door. - ANSWER1. Head
2. Top Rail
3. Panel

, 4. Lock Rail
5. Hinge Jamb
6. Strike Jamb
7. Stile
8. Bottom Rail
9. Sill

When would you choose to label the base of a door elevation a Sill rather than a
Threshold? - ANSWERIf you cannot see a distinction between the sill and threshold,
choose Sill. If there was a section view showing the actual threshold, then you can label
it. Otherwise the base of a door is a Sill.

Do showers, balconies, and closets count towards the max travel distance? -
ANSWERYES!!

What is the minimum path width of a pass-through kitchen? - ANSWER40"

If, per the program, a restroom is not accessible, and a questions asks for accessibility
requirements, what should you always keep in mind? - ANSWERthe toilet distance from
the nearest adjacent wall.

What is non-accessible counter height? - ANSWER36"

What is the accessible mounting height for mirrors? - ANSWERthe edge of the reflective
surface should be no higher than 40"

When taking the PRAC, see if you need to measure to ________ _________ of an
intermediate partition or wing wall. - ANSWERboth faces

What types of fixtures would require plumbing trench extensions? - ANSWERall of
them. it's not the type of fixture that determines the need for an extension, its the type of
drain fixture (floor or wall) and whether the floor drain is directly on the trench or the wall
that the wall drain mounts to is within 10' of the trench.

Storage rooms over _______sf must be _______. - ANSWER100sf, 1 hour fire rated

How is a partition made to be 1 hour rated? - ANSWERbrought to deck, 2 layers of fire
rated gyp

The interior deisgner should measure to the inside ________ of the exterior wall
according to ANIS/BOMA Z65.1. - ANSWERGlass Surface / Glass (if the exterior wall is
more than 50% glass) OR Surface (if the exterior wall is less than 50% glass)

To be accessible egress, stairs must be a minimum of _____________. - ANSWER48"
or 44" between handrails depending if the building is sprinklered or not.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Americannursingaassociation. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $18.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75057 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$18.99
  • (0)
  Add to cart