100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Florida Home Inspector Exam Questions With Correct Answers 2024 $18.49   Add to cart

Exam (elaborations)

Florida Home Inspector Exam Questions With Correct Answers 2024

 1 view  0 purchase
  • Course
  • Florida Home Inspector
  • Institution
  • Florida Home Inspector

Florida Home Inspector Exam Questions With Correct Answers 2024

Preview 4 out of 86  pages

  • October 15, 2024
  • 86
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • are service late
  • Florida Home Inspector
  • Florida Home Inspector
avatar-seller
RANKGRADES
Florida Home Inspector Exam Questions
With Correct Answers 2024



Service .entrace .conductors .run .from .the .service .drop .to .the .service .box .or .service .panel.
.True .or .False? .- .correct .answer.True




The .service .size .is .determined .by .the .amperage .and .the .voltage .ratings .of .the .service. .-
.correct .answer.True




Is .the .service .drop .overhead .or .underground? .- .correct .answer.Overhead

Are .service .laterals .overhead .or .underground? .- .correct .answer.Underground

The .drip .loop .is .typically .part .of .the .service .drop. .True .or .False? .- .correct .answer.False

The .wire .size .for .the .service .drop .must .be .the .same .as .the .wire .size .for .the .service
.entrance .conductors. .True .or .False? .- .correct .answer.False




How .many .wires .would .you .typically .find .in .a .240-volt .service .drop? .- .correct .answer.3

What .would .4 .wires .mean? .- .correct .answer.3-phase .electricity

What .would .2 .wires .usually .mean? .- .correct .answer.120 .volt .service

List .7 .common .problems .with .service .drops. .- .correct .answer.1. .Overhead .wires .too .low.
2. .Damaged .or .frayed .wires.
3. .Trees .or .vines .interfering .with .wires.
4. .Wires .too .close .to .doors .or .windows.
5. .Wires .not .well-secured .to .the .house.
6. .Poor .connection .between .service .drop .and .service .entrance.
7. .Inadequate .clearance .from .roofs.

List .clearances .above .ground, .swimming .pools, .and .roofs. .- .correct .answer.above
.roadway--18 .ft.

above .driveway--12 .ft.
above .flat .roof--8 .to .10 .ft.
above .sloped .roof--18 .inches
away .from .water .in .swimming .pool--22.5 .ft

,3 .ft. .above .sloped .roof .with .pitch .> .4 .in .12
above .walkway--10 .ft.

The .service .entrance .conductors .run .from .the ._________ .to .the .___________. .- .correct
.answer.service .drop .to .service .box




All .service .entrance .conductors .must .be .in .conduit. .True .or .False? .- .correct .answer.False

All .service .entrance .conductors .must .be .attached .above .roof .level. .True .or .False? .-
.correct .answer.False




The .drip .loop .should .be .as .close .to .the .roof .as .possible. .True .or .False? .- .correct
.answer.False




List .10 .common .problems .with .service .entrance .conductors. .- .correct .answer.1. .No .drip
.loop

2. .No .mast .head
3. .Mast .head .not .weather .tight.
4. .Mast .or .conduit .bent.
5. .Mast .or .conduit .rusted.
6. .Mast .rotted .(if .wood).
7. .Mast .conduit .or .cable .not .well .secured.
8. .Mast .conduit .or .cable .not .weather .tight.
9. .Conduit .or .cable .not .well .sealed .at .house/wall .penetration.
10. .Cable .frayed, .damaged, .or .covered .by .siding.

List .4 .common .areas .of .water .penetration .into .service .entrances. .- .correct .answer.1.
.conduit .joints

2. .mast .head
3. .roof .flashing
4. .meter .base
5. .house .entry

List .2 .functions .of .the .drip .loop. .- .correct .answer.1. .Prevents .water .entry .into .the .conduit
.or .service .entrance .conductors.

2. .Shows .that .the .service .drop .wires .are .not .straining .the .splices.

Roughly .999 .out .of .1000 .houses .have ._________ .volts .available. .- .correct .answer.240

Roughly .999 .out .of .1000 .houses .have .__________ .service .entrance .wires. .- .correct
.answer.3




Load .calculations .are .part .of .a .home .inspection. .- .correct .answer.False

Implications .of .an .undersized .service .include:
a. .shock .hazard

,b. .fire .hazard
c. .shock .and .fire .hazard
d. .melting .insulation
e. .nuisance .tripping .of .the .main .fuses .and .breakers .- .correct .answer.e.

What .is .the .largest .single-phase .service .that .you .are .likely .to .find .in .a .home? .- .correct
.answer.400 .amps




What .size .copper .wire .would .you .expect .to .find .on .the .service .entrance .for:
a. .60-amp .service
b. .100-amp .service
c. .200-amp .service .- .correct .answer.a. .6 .gauge
b. .4 .gauge
c. .2-0 .gauge

Which .of .the .following .is .a .reliable .way .to .identify .the .service .size?
a. .the .size .of .the .service .drop .wires
b. .the .distribution .panel .rating
c. .the .service .box .rating
d. .the .service .entrance .conductor
e. .the .service .entrance .conduit .size .- .correct .answer.d.

Aluminum .is .an .acceptable .service .entrance .conductor .material. .True .or .False? .- .correct
.answer.True




A .fused .200-amp .service .has .two .100-amp .fuses .in .the .service .box. .True .or .False? .-
.correct .answer.False




If .you .can't .read .the .size .of .the .fuses .in .the .service .box, .you .should .remove .them .to .try .to
.get .a .better .look. .True .or .False? .- .correct .answer.False




Which .of .the .following .is .a .safety .issue:
a. .The .main .fuses .have .a .lower .rating .than .the .service .entrance .wire.
b. .The .main .fuses .have .a .higher .rating .than .the .service .entrance .wire.
c. .The .service .box .has .a .higher .rating .than .the .service .entrance .wires.
d. .The .service .box .has .the .same .rating .as .the .service .entrance .wires.
e. .The .distribution .panel .has .a .larger .rating .than .the .service .entrance .wires. .- .correct
.answer.b




The .service .box .can .be .inside, .outside, .or .in .the .garage. .True .or .False? .- .correct
.answer.True




There .can .be .up .to .10 .throws .to .disconnect .all .the .electricity .in .the .house. .True .or .False?
.- .correct .answer.False

, The .service .box .may .stand .alone .or .may .be .combined .with .the .distribution .panel. .True .or
.False? .- .correct .answer.True




List .common .conditions .you .might .find .in .a .service .box. .- .correct .answer.1. .poor .access
.or .location

2. .loose
3. .rust .or .water .in .box
4. .unprotected .opening
5. .damaged .parts
6. .overheating
7. .incorrect .fuse .or .breaker .size; .box .rating .too .small
8. .service .entrance .wires .exposed .in .house
9. .poor .connections
10. .illegal .taps
11. .neutral .wire .by-passes .service .box
12. .fused .neutral .wire
13. .fuses .upstream .of .disconnect .switch
14. .obsolete .box
15. .exterior .box .not .weather-tight
16. .box .not .rated .for .aluminum

The .functions .of .earth .grounding .systems .include: .- .correct .answer.1. .Dissipate .electricity
.from .lightning.

2. .Avoid .static .electricity .buildup.

The .grounding .electrode .conductor .may .also .be .called .__________. .- .correct .answer.the
.ground .wire




You .are .allowed .to .ground .to .the .gas .piping. .True .or .False? .- .correct .answer.False

The .grounding .systems .are .connected .to .the .house .neutral .at .the .___________. .- .correct
.answer.Service .box




From .the .point .where .the .ground .and .neutral .wires .connect, .there .are .2 .paths .to .ground.
.What .are .they? .- .correct .answer.Through .the .neutral .service .wire .or .through .the

.grounding .electrode .conductor .to .water .pipes .or .ground .rods.




List .5 .destinations .where .ground .wires .can .terminate. .- .correct .answer.1. .metal .water
.pipes

2. .metal .rods .driven .into .the .ground
3. .wires .buried .in .the .footings .(UFER .ground)
4. .buried .grounding .plates .or .rings
5. .frame .of .metal .buildings
6. .metal .well .casings

List .common .problems .found .with .grounding .systems. .- .correct .answer.1. .no .ground

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller RANKGRADES. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $18.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80562 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$18.49
  • (0)
  Add to cart