1 (8497) - Which section of a turbine engine provides high pressure bleed air to an air cycle machine for pressurization and air-conditioning? - Answers A- Low or high pressure compressor
2 (8498) - At wh...
ASA Cabin Atmosphere Control system Review Questions with Complete Solutions Already Passed
1 (8497) - Which section of a turbine engine provides high pressure bleed air to an air cycle machine for
pressurization and air-conditioning? - Answers A- Low or high pressure compressor
2 (8498) - At which component in an air-cycle cooling system does air undergo a pressure and
temperature drop? - Answers A- Expansion turbine.
3 (8499) - In a freon vapor-cycle cooling system, where is cooling air obtained for the condenser? -
Answers B- Ambient air.
4 (8500) - What is ventilating air used for on a combustion heater? - Answers B- Carries heat to the
places where needed.
5 (8501) - Turbine engine air used for air-conditioning and pressurization is generally called - Answers C-
bleed air.
6(8502) - In the combustion heater, combustion air system, what prevents too much air from entering
the heaters as air pressure increases? - Answers A- Either a combustion air relief valve or a differential
pressure regulator.
7 (8503) - The cabin pressure of an aircraft in flight is maintained at the selected altitude by - Answers C-
controlling the rate at which air leaves the cabin.
8 (8504) - What controls the operation of the cabin pressure regulator? - Answers A- Cabin altitude.
9 (8505) - The basic air-cycle cooling system consists of - Answers A- a source of compressed air, heat
exchangers, and a turbine.
10 (8506) - The purpose of the dump valve in a pressurized aircraft is to relieve - Answers A- all positive
pressure from the cabin.
11 (8507) - What component might possibly be damaged if liquid refrigerant is introduced into the low
side of a vapor-cycle cooling system when the pressure is too high or the outside air temperature is too
low? - Answers A- Compressor.
12 (8508) - How can it be determined that a vapor-cycle cooling system is charged with the proper
amount of freon? - Answers A- Air bubbles in the sight glass disappear.
13 (8509) - When charging a vapor-cycle cooling system after evacuation, the low-pressure gauge fails to
come out of a vacuum. What is indicated? - Answers A- Blockage in the system.
14 (8510) - What component in a vapor-cycle cooling system would most likely be at fault if a system
would not take a freon charge? - Answers A- Expansion valve.
15 (8511) - Frost or ice buildup on a vapor-cycle cooling system evaporator would most likely be caused
by - Answers C- inadequate airflow through the evaporator.
, 16 (8512) - What test is used to determine the serviceability of an oxygen cylinder? - Answers C-
Pressure test with water.
17 (8513) - How often should standard weight high-pressure oxygen cylinders be hydrostatically tested?
- Answers A- Every 5 years.
18 (8514) - To be eligible for recharging, a DOT 3HT oxygen cylinder must have been hydrostatically
tested every three years and be retired from service after - Answers A- 24 years or 4,380 filling cycles.
19 (8515) - What type of oxygen system uses the rebreather bag-type mask? - Answers B- Continuous
flow.
20 (8516) - The altitude controller maintains cabin altitude by modulation of the - Answers C- outflow
valve.
21 (8517) - Hot compressor bleed air operates the conditioned air system on some turbine aircraft, cold
air supplied by the - Answers C- ram air cycle cooling unit.
22 (8518) - For use in pressurized aircraft, which is generally the least complicated and requires the least
maintenance? - Answers A- Chemical oxygen generator systems.
23 (8519) - The main cause of contamination in gaseous oxygen systems is - Answers A- moisture.
24 (8520) - Where does the last stage of cooling in an air-cycle air-conditioning system occur? - Answers
C- Expansion turbine.
25 (8521) - The point at which freon flowing through a vapor-cycle cooling system gives up heat and
changes from a gas to a liquid is the - Answers A- condenser.
26 (8522) - The point at which freon flowing through a vapor-cycle cooling system absorbs heat and
changes from a liquid to a gas is the - Answers B- evaporator.
27 (8523) - How is the cabin pressure of a pressurized aircraft usually controlled? - Answers B- By an
automatic outflow valve that dumps all the pressure in excess of the amount for which it is set.
28 (8524) - Which is considered a good practice concerning the inspection of heating and exhaust
systems of aircraft utilizing a jacket around the engine exhaust as a heat source? - Answers A-
Supplement physical inspections with periodic operational carbon monoxide detection tests.
29 (8525) - On some cabin pressurization systems, pressurization on the ground is restricted by the -
Answers A- main landing gear operated switch.
30 (8526) - The cabin pressure control setting has a direct influence upon the - Answers A- outflow valve
opening.
31 (8527) - The function of the evaporator in a freon cooling system is to - Answers B- lower the
temperature of the cabin air.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller TutorJosh. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $7.99. You're not tied to anything after your purchase.