Nicet Fire Alarm Level 1 Questions And Answers Guaranteed Success.
1 view 0 purchase
Course
Nicet Fire Alarm Level 1
Institution
Nicet Fire Alarm Level 1
Nicet Fire Alarm Level 1 Questions And Answers Guaranteed Success.
Break locks prevent - correct answer. a non-energized break from being turned on by an unauthorized person.
Hard hats must be worn on the job only if people are working above you or it is possible an object may fall o...
Nicet Fire Alarm Level 1 Questions And
Answers Guaranteed Success.
Break locks prevent - correct answer. a non-energized break from being turned on by
an unauthorized person.
Hard hats must be worn on the job only if people are working above you or it is possible
an object may fall on you. - correct answer. False
What is not true regarding noise exposure limits set by osha? - correct answer. When
the daily noise exposure is composed of two or more periods of noise exposure of
different levels, the maximum sound shall be used.
When the scaffolds working platform reaches a certain height above the ground,
handrails and toe guards are required, what is that height in feet? - correct answer. 10
Who is responsible for the development and maintenance of an effective fire protection
and prevention program at the fire alarm installation job site? - correct answer. the
alarm contractor
What is the maximum distance from the wall permitted for the bottom of an 18 foot
ladder when leaning against a wall? - correct answer. 4-1/2 feet
A tool belt is an example of a PPE? - correct answer. False
Can a type I industrial step ladder be made of wood? - correct answer. Yes
What is the height limit of Type II commercial step ladders? - correct answer. 12 feet
Are you and your assistant required to wear eye protection when using an explosive
actuated fastening tool? - correct answer. Yes
Scaffold planks shall be replaced if they have been used for ground support, have any
splits, or have layers or paint, plaster, etc. - correct answer. True
The total allowable sound pressure level produced by combining the ambient sound
pressure and all audible notification appliances operating was lowered in the 2007
, edition to what db level and what is the length of time OSHA permits workers to be
exposed to these levels per eight hour work day? - correct answer. 110db and 1/2
hour
Scaffolds and their components shall be capable of supporting without failure, at least
_______ times their maximum intended load? - correct answer. four
On a powered scissor lift, per OSHA a personal fall system is required. - correct
answer. False
For safety, is it permitted to use a rope to tie off the bottom of a ladder to the building
structure? - correct answer. True
How many feet above the roof must your ladder extend when using the ladder to access
the roof? - correct answer. 3 feet
Monitoring for integrity of a circuit is not required if a single open or ground-fault causes
an alarm signal. - correct answer. False
The circuit disconnecting means for a fire alarm system to the light and power service
shall _____ - correct answer. have a red marking and identified as "FIRE ALARM"
On a Class B Initiating Device Circuit, which devices on the circuit will remain
operational during a single open trouble condition? - correct answer. Device located
up to (before) a single open condition
When installing a 2-wire smoke detector with separate IN and OUT terminals for the
positive wire, what would be the result of installing both the incoming and outgoing
positive wires under the same positive IN terminal? - correct answer. Detector not
supervised but circuit would function
With a 24vdc circuit and a 480 Ohm resistor, what is the milliamps of the circuit? -
correct answer. 50
What is the DC resistance of 500'ft of 18 awg coated, solid copper wire measured at
75C (167F)? - correct answer. 4.04 Ohms
375 mA (milliamps) can also be expressed as ______ - correct answer. .375 amps
All styles of Class A circuits using physical conductors shall be installed such that the
outgoing and return conductors, exiting from and returning to the control unit,
respectively, are _________ - correct answer. routed separately
A commercial office building's power limited fire alarm system requires a vertical cable
run between 4 floors. What type of cable is required for this if the cable will not be
installed in a metal raceway of fireproof shaft? - correct answer. FPLR or FPLP
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller techgrades. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.99. You're not tied to anything after your purchase.