UDC was required at time of installation for all systems installed after?
January 1, 2000
July 1, 2005, service techs shall possess or work under someone who has a
current certification indicating he or she has passed the?
ICC UST Service Technician Exam ICC
cert must be renewed every?
24 months
Service techs must possess or be employed by a person who has the
appropriate contractor's license unless?
The individual has a tank testing license
Service tech is defined by any individual who?
Tests UST monitoring equipment, trouble shoots UST systems, and/or installs
UST monitoring equipment.
If the manufacturer training no longer exist, the local agency may?
Approve comparable alternate training .
UST includes?
Tank and connected piping What
is considered a UST?
A petroleum storage tank.
What UST system meets the requirements for secondary containment?
Doubled wall tanks
,According to title 23; the following piping components if installed after July 1,
1987 must have secondary containment.
Pressured product piping
Considered "pipe" on tanks installed after July 1, 2003.
Pressured product piping and below ground vapor recovery. Under
dispenser containment (UDC) was required for all existing UST
systems by December 31, 2003
System for exchanging gas vapors in a storage tank and product in a fuel
delivery truck
Stage 1 vapor recovery
An approved method for non-visual monitoring for existing UST systems.
Statistical Inventory Reconciliation (SIR)
ATG must be capable for detecting a release of?
0.2 gallons per hour
What is no longer an approved method for non-visual monitoring on existing
UST systems?
Manual inventory reconciliation.
Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of detecting a leak of ?
3 gallons per hour at 10 psi
How often should ATG be programmed to test the tank?
At least monthly
According to PEI RP 300, a combustible gas can be used to?
Detect vapor leaks in a vapor recovery system.
According to PEI RP 300, a written scope of work for vapor recovery
installation should include?
,Construction plans
Positive shut off overfill protection device must stop the flow of fuel when the
tank is no more then?
95% full
According to Executive Order (EO) VR 201-A , what could cause a nozzle
shut off mechanism or malfunction?
Depended filter seal damage
According to VR 201-A, breakaway reconnection must be?
Logged in GDF log
According to PEI RP 300 what is an INCORRECT method of documenting
piping location?
Sketching a diagram on the inside cover of vapor recovery equipment manual
According to PEI RP 300 as built drawing or pictures of the underground
pipping and other components shall be_________. maintained as long as UST
is in service.
According to EO VR 101-E maintenance records are required to include
what?
Name and Designated UST Operator.
The Phil-Tite EVR Phase 1 system require that vapor vent pipes at any UST
system be
Used with no more than 3 p/v valves
According to EO VR 2010 after installing a new spout assembly in the Healy
900 nozzle the following test must be conducted?
Nozzle dispensing shut off test
According to Healy EO VR 201-A a vapor recovery record is to be maintained
by?
Gasoline dispensing facility operator(GDF)
, An enhanced leak detection test is required within how many feet of a public
drinking well?
1000 feet
What are the components of the Fire Triangle?
Fuel, Heat/Ignition Source, Oxygen
If equipped with an over fill alarm, it must be located?
So it can be seen or heard from the delivery location.
If installed, the following requires independent 3rd party certification to
prove compliance with established regulations. Automatic Tank Gauge,
Liquid Product Detectors, SIR Where are ATG's installed?
Opening in top of the tank
What is true about ATG's
They're capable of alarming operator of low product level
The following types of releases must be reported to the local agency. Releases
greater than 25 gallons that escape secondary containment. Release that
escape primary containment. Releases less than 25 gallons which escape
secondary containment
If an unauthorized product release meets the requirements for reporting to
the local agency, verbal notification must be made within ____hours, followed
by a written notification within ____days.
24 HRS, 5 DAYS
The following unusual conditions shall be reported to the local agency,
EXCEPT:
Water in spill buckets
If the monitoring system detects a leak that has occurred, the local agency
must be notified unless______.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller nyagajoseph539. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $24.49. You're not tied to anything after your purchase.