100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Ohio fire alarm Questions and Answers 2024 $15.99   Add to cart

Exam (elaborations)

Ohio fire alarm Questions and Answers 2024

 8 views  0 purchase
  • Course
  • Fire Alarm
  • Institution
  • Fire Alarm

Ohio fire alarm Questions and Answers 2024 Where Public Mode audible appliances are installed they shall be ____________ above average ambient sound level 15dba Where audible appliances are installed in mechanical equipment rooms, the average ambient sound level is 85dba Previous...

[Show more]

Preview 2 out of 10  pages

  • October 3, 2024
  • 10
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Fire Alarm
  • Fire Alarm
avatar-seller
julianah420
Ohio fire alarm Questions and Answers
2024


Where Public Mode audible appliances are installed they shall be ____________ above
average ambient sound level - answer15dba

Where audible appliances are installed in mechanical equipment rooms, the average
ambient sound level is - answer85dba

An average ambient sound level greater than ______ shall require the use of a visible
notification appliance - answer105dba

All fire detection devices shall be listed or approved for the purpose for which they are
intended - answerTrue

A detector should not be recessed in any way unless they have been tested for such a
mounting - answerTrue

How far from the doorway shall a Manual fire alarm station be mounted - answer5'

Vane type flow switch have no longer than _____ to initiate alarm - answer90 sec

smoke detectors must be tested every - answer1 year

Sensitivity in smoke detectors and single & multiple-station smoke alarms in other than
1&2 family dwellings shall be checked within _____ year or years after installation -
answer1 year

A spot-type heat detector located on a wall shall not be more than _____ inches from
the ceiling - answer12''

With a peak ceiling, heat and smoke detectors shall be located within _____ of the
peak, measured horizontally - answer36''

smoke detectors shall not be located near - answerAir supply diffusers

When beams project more than _____ inches below the ceiling and are more than 8' on
center, each bay formed by the beams shall be treated as a separate area for heat
detectors - answer18''

, When manual fire alarm boxes are used, the distance between boxes will not be in
excess of - answer200'

A water flow device should be field adjusted so that an alarm is initiated in no more than
_____ seconds - answer90 seconds

smoke detectors shall not be located directly in the air stream of - answersupply
registers

Detectors shall not be installed until after - answerFinal clean up of all trades

a heat detector integrally mounted on a smoke detector shall be listed and approved for
not less than - answer50'

Detectors for common return systems should be installed up to ______ in front or
behind openings - answer12''

A line-type obsucration smoke detector, where the light beam is projected across the
area to be protected - answerprojected beam smoke detector

A device which detects the visible particles of combustion is a ____ detector -
answerSmoke

Manual Fire alarm boxes shall not be less than _______ inches and not more than
______ inches above the floor level - answer42/48

single and multiple stations smoke alarms shall be tested after the initial installation test
every ____ - answer1 year

smoke detectors installed within _______ feet of cooktop or range must be of the _____
type - answer20 feet/photo

Dwelling smoke alarms must produce an audible _____ signal for at least _____
minutes - answerevacuation/ 4 minutes

Rechargeable power supplies for smoke alarms must recharge in _____ hours or less
when connected to a _____ portion of branch circuit - answer4/switched

smoke detectors must be installed within ______ feet of a door to a sleeping room -
answer21 feet

Wall mounted heat detectors must be mounted between _____ and _____ inches from
a ceiling - answer4''/12''

a fire alarm system must operate on standby for a period of not less than ______ days
followed by at least ______ minutes of alarm - answer7/4

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $15.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$15.99
  • (0)
  Add to cart