100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Fire alarm lesson 5&6 Questions and Answers 100% Correct $17.49   Add to cart

Exam (elaborations)

Fire alarm lesson 5&6 Questions and Answers 100% Correct

 7 views  0 purchase
  • Course
  • Fire Alarm
  • Institution
  • Fire Alarm

Fire alarm lesson 5&6 Questions and Answers 100% Correct Which article of the NEC covers burglary system wiring? Article 725 Correct Non-power-limited circuits operate with voltages up to ? . 600 V Previous Play Next Rewind 10 seconds Move forward 10 seconds Unmute 0:08 / ...

[Show more]

Preview 2 out of 7  pages

  • October 3, 2024
  • 7
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Fire Alarm
  • Fire Alarm
avatar-seller
julianah420
Fire alarm lesson 5&6 Questions and
Answers 100% Correct

Which article of the NEC covers burglary system wiring? - answer Article 725 Correct

Non-power-limited circuits operate with voltages up to ? . - answer600 V

Tables ? and ? provide limitations for power-limited circuits. - answer12A and 12B

Generally speaking, power-limited fire alarm circuits operate at ? . - answerless than
100 VA

Power-limited wiring requirements are found in Part ? of Article 760. – answer III

Power-limited equipment circuit limitations are verified by ? . – answer The testing
laboratory

Underground power-limited copper fire alarm circuits that extend outside the building
must comply with ? . - answerParts II, III, and IV of Article 800 and Part I of Article 300

Fire alarm cables are permitted to be laid directly on top of suspended ceiling tiles. -
answerFalse

The inside of a conduit installed under a concrete slab at grade level is considered a ?
location. - answerWet

What cable type is suitable for two hours of direct attack by fire? - answerFPLP-CI

Fire alarm circuit survivability is required for systems using ? . - answer. partial
evacuation or relocation

Circuit integrity (CI) cable can be spliced with off-the-shelf twist-on connectors between
the controls and the zone it serves. - answerFlase

Power-limited circuits may be wired using ? . - answer1. Chapter 3 wiring methods
2. non-power-limited wiring methods
3. power-limited wiring methods

Assuming that there are no approved separations between conductors, which of the
following conductors are permitted in the same cable or raceway as power-limited circuit
conductors? - answerClass 2

, Which cable type is permitted to be installed exposed in a plenum space? -
answerFPLP

Failure to remove conduit burrs usually results in ? . - answerground faults

The proper non-power-limited cable for riser use is ? . - answerNPLFR

Under what conditions can abandoned fire alarm cables remain in a building? -
answerWhen they are tagged for future use

Non-power-limited circuits may be wired using which of the following? - answerTHHN in
EMT

Where non-power-limited wiring is installed exposed, it must be mechanically protected
within ? of the finished floor. - answer7'

Fire alarm circuit conductors above a suspended ceiling may use the same support
wires that support the ceiling grid. - answerFalse

Fire alarm cables are permitted to be strapped to other conduit. - answerFalse

The location of unit resistances for copper wire is found in ? of the NEC. - answerTable
8

An 18 AWG uncoated solid copper conductor has a unit resistance of ? per 1,000 feet. -
answer7.77 Ω

A circuit that is 1,500 feet from the control unit to the last device will have a loop
resistance of ? , when an 18 AWG uncoated solid copper conductor is used. -
answer23.310 Ω

What is the length of a 16 AWG solid coated copper conductor having a resistance of
23.5 ohms? - answer4,626'

Firestopping materials are always listed - answerFalse

A firestopping classification having a minimum F rating of ? must be used on a two-hour
rated firewall to resist the passage of flames. - answer120

NEC ? requires electrical penetrations to be firestopped. - answer300.21

A firestopping material that expands when heated is referred to as ? . -
answerIntumescent

A cable tray is considered a ? penetration. - answerDynamic

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.49
  • (0)
  Add to cart