Fire Alarm Midterm

The primary purpose of dwelling fire warning equipment is ? . - answer life safety

Single-station smoke alarms for dwelling use became available in the ? . - answer1970s

Which of the following areas is covered under the requirements of NFPA 72, Chapter
29? - answer an apartment

Heat alarms or detectors installed on ceilings that consist of beams or joists must be
installed? . - answer on the bottoms of the beams or joints

Areas of a dwelling over ? require additional smoke alarms or detectors. - answer1000
square feet

Which device, when actuated and interconnected to another similar device, will cause
the other device to actuate? - answer Ulti-station alarm

Actuation of multiple-station smoke alarms cannot cause actuation of ? . - answer all of
the above

Single-station and multiple-station smoke alarms can be used in an office building to
provide occupant warning. - answerfalse

Dwelling smoke alarms can be installed in ambient temperatures between ? and ? . -
answer40 degrees F/ 100 degrees F

The most appropriate type of detection in dwelling garages, unfinished attics, or crawl
spaces is ? . - answerheat detector

Wall-mounted heat detectors must be mounted so the top of the detector is between ?
and 12 inches from the ceiling. - answer4"

What is the maximum number of unmonitored smoke alarms that can be
interconnected? - answer12

Smoke alarms or detectors on peaked ceilings must be within ? of the peak. - answer3'

Heat detectors and alarms mounted on a ceiling must be mounted at least ? from a wall.
- answer4"

, For the purposes of life safety, Chapter 29 of NFPA 72 requires the primary means of
fire detection in dwellings to be which of the following types of detection? -
answersmoke detector

The fire alarm signal in a dwelling sleeping room must be not less than ? at the pillow. -
answer75 dBA

A 110-candela visible notification appliance used to awaken a sleeping person must be
mounted more than ? from the ceiling. - answer24"

A new two-story single-family dwelling with a basement and three bedrooms on the
second floor requires a minimum of ? smoke alarms. - answer6

Heat detectors used in dwellings must have a listed spacing of not less than ? . -
answer50'

Dwelling heat detectors must be selected to operate at a temperature not less than ?
above the maximum expected ambient temperature in the protected space. - answer25
degrees F

The Code requires smoke alarms or detectors within ? to ? of a range or cooktop to be
either of the photoelectric type or to have a silence feature. - answer10'/20'

Smoke detectors or alarms must be located at least ? from a supply diffuser or tips of a
paddle fan. - answer3'

Smoke alarms or detectors in a basement must be ? . - answermounted on the
basement ceiling near the stairs

Where AC is the primary supply for dwelling fire alarm or carbon monoxide systems, the
supply must be fed from a(n) ? . - answereither a or c is acceptable

A primary power source for smoke detector equipment may consist of ? . - answerany of
the above

Carbon monoxide (CO) alarms or detectors must be ? . - answerlocated in all rooms
containing a fossil fuel burning appliance

Which of the following is not one of the three primary fire protection elements for
providing fire protection in a building? - answerreporting

Which of the following are considered primary functions of a fire alarm system? I.
Actuation of emergency control functions II. Early detection of fires III. Notification of the
fire department IV. Occupant notification V. Supervision of other systems - answerall of
the above

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79976 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.99
  • (0)
  Add to cart