Asbestos Test Study Guide questions with correct
answers
Category 1 nonfriable asbestos-containing material (AMC) Correct
Answer-means asbestos-containing packages, gaskets, resilient floor
covering, and asphalt roofing products containing more than 1 percent
asbestos as determined using the method specified in appendix E,
subpart E, 40 CRF part 763, section 1, Polarized Light Microscopy
Category II nonfiriable AMC Correct Answer-means any material,
excluding Category I nonfirable AMC, containing more than 1 percent
asbestos as determined using the method specified in appendix E,
subpart E, 40 CRF part 763, section 1, Polarized Light Microscopy that ,
when dry, cannot be crumbled, pulverized, or reduced to powder by
hand pressure
Demolition Correct Answer-means the wrecking of tacking out of any
load-supporting structural member of a facility together with any related
handling operations or the international burning of any facility
Friable asbestos material Correct Answer-means any material containing
more than 1 percent asbestos as determined using the method specified
in appendix E, subpart E, 40 CRF part 763, section 1, Polarized Light
Microscopy that , when dry, can be crumbled, pulverized, or reduced to
powder by hand pressure. If the asbestos content is less than 10 percent
as determined by a method other than point counting by polarized light
microscopy (PLM), verify the asbestos content by point counting using
PLM.
, Regulated asbestos-containing material (RAMC) Correct Answer-means
(a) Friable asbestos material, (b) Category I nonfriable AMC that has
become friable, (c) Category I nonfirbale AMC that will be or has been
subjected to sanding, grinding, cutting, or abrading, or (d) Category II
Nonfirable ACM that has become crumbled, pulverized, or recorded, or
reduced to powder by the forces expected to act on the material in the
course of demolition or renovation operations regulated by this subpart
Renovations Correct Answer-means altering a facility or one or more
facility components in any way, including the stripping or removal of
RAMC from a facility component. Operations in which load-supporting
structural members are wrecked or taken out of demolitions.
Visible emissions Correct Answer-means any emissions, which are
visually detectable with out the help of instruments, coming form
RAMC or asbestos-containing waste material, or form any asbestos
milling, manufacturing, or fabricating operations. This does not include
condensed, uncombined water vapor
61.145 Standard for demolition and renovation (a) 1 (i) Correct Answer-
At least 80 linear meters (260 linear feet) on pipes or at least 15 square
meters (160 square feet) on another facility components
61.145 Standard for demolition and renovation (a) 1 (ii) Correct
Answer-At least 1 cubic meter (35 cubic feet) off facility components
where the length or area could not be measured previously