During a TXV repair, refrigerant was recovered from the system. The refrigerant
________. - ANSWER: can be charged back into the same system after repairs are
made and the system is leak checked and properly evacuated

When charging an R-410A refrigeration system with a water-cooled evaporator, to
avoid freezing the water in the evaporator, operate the water pump and charge the
system with vapor first until a pressure of about ________ is achieved. - ANSWER:
110 psig

________ indicates low charge in a high-pressure system with a capillary tube. -
ANSWER: Excessive superheat

The EPA recommends that ________ should be used to remove ice from a sight
glass. - ANSWER: isopropyl alcohol

Before using a recovery unit, you should ________. - ANSWER: check the service
valve positions and recovery oil level (if recovery compressor is not oil less) before
turning the recovery unit on

After reaching the required recovery vacuum on a system, ________. - ANSWER:
wait at least a few minutes to see if the system pressure rises

After installing a new split-system AC unit, the next step is to ________. - ANSWER:
pressurize with nitrogen and leak check the system

Which repair is ALWAYS considered "major system repair" under EPA's regulations? -
ANSWER: replacement of a condenser

Before recovering refrigerant into an empty recovery tank, you must ________. -
ANSWER: evacuate the cylinder

What must owners/operators do if their supermarket system that contains 60
pounds of R-22 leaks more than 125% of its full charge in a calendar year? -
ANSWER: Submit a report to EPA describing efforts to identify leaks and repair the
appliance

After buttoning up a system, the next step is to ________. - ANSWER: pressurize with
nitrogen and leak check

You have repaired a significant leak in an industrial process refrigeration system that
contains 1000 pounds of R-404A. How often is the owner required to perform a leak
inspection to verify the system is no longer leaking? - ANSWER: Every 3 months

, Recovering refrigerant as a vapor minimizes the removal of ________ from the
system. - ANSWER: oil

________ appliances are defined by the EPA as refrigeration appliances used in the
retail food and cold storage warehouse sectors. - ANSWER: Commercial refrigeration

Whenever you are using nitrogen to flush a system or break a vacuum, always use
________. - ANSWER: nitrogen gas not liquid nitrogen

a pressure regulator

a pressure relief valve downstream

Every refrigerating system must be protected by ________. - ANSWER: a pressure
relief device

What must an owner of a commercial refrigeration appliance with a charge of 2000
pounds of R-22 do when the leak rate threshold has been exceeded? - ANSWER:
Take further action by repairing, retiring, mothballing, or retrofitting the appliance.

The ________ is located downstream of the evaporator and before the compressor.
- ANSWER: accumulator

An HVAC company must keep records for each disposed appliance with a charge
between 5 and 50 pounds for ________. - ANSWER: 3 years

A hermetic compressor will overheat if operated in a vacuum because ________. -
ANSWER: the compressor motor uses the flow of refrigerant through the compressor
for cooling

If you back-seat a compressor discharge shutoff valve, you ________. - ANSWER:
close the gauge port

________ is a potential refrigerant for a low-pressure chiller. - ANSWER: R-123

If the ________, a reciprocating compressor could be damaged if energized. -
ANSWER: discharge service valve is closed

According to the EPA, soap bubbles are best used to ________. - ANSWER: pin point
refrigerant leaks

A factory has a chiller with 200 pounds of charge that uses 65% of the chiller's
cooling capacity to cool a manufacturing line and the remaining 35% of the chiller's
cooling capacity is used to air condition the office space in the factory. Which leak
rate category would this chiller be in? - ANSWER: industrial process refrigeration

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller salopchemay. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

83100 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart