100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ASPE CPD Study Questions AH Questions and Answers | Latest Update $13.49   Add to cart

Exam (elaborations)

ASPE CPD Study Questions AH Questions and Answers | Latest Update

 4 views  0 purchase
  • Course
  • ASPE CPD
  • Institution
  • ASPE CPD

Front Back What is the specific weight of water? 62.4 lbs per cubic foot What happens in a storm and sanitary system after it passes the water test? A smoke pressure test is recommended with a smoke pressure of 1 in wc to prove the system gas tight. Is an air test acceptable for a storm ...

[Show more]

Preview 4 out of 87  pages

  • September 26, 2024
  • 87
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ASPE CPD
  • ASPE CPD
avatar-seller
TestTrackers
2024/ 2025 | © copyright | This work may not be copied for profit gain Excel!

ASPE CPD Study Questions AH Questions
and Answers | Latest Update
Front


✓ Back




What is the specific weight of water?


✓ 62.4 lbs per cubic foot




What happens in a storm and sanitary system after it passes the water test?


✓ A smoke pressure test is recommended with a smoke pressure of 1 in

wc to prove the system gas tight.




Is an air test acceptable for a storm and sanitary system?


✓ Yes, if a water test is not possible, at a pressure of 5 psi, are tests are

impractical and costly




What are the testing procedures for the storm and sanitary system?


✓ A water test upon completion of the rough piping and prior to

concealment of 10 ft wc minimum (except the topmost 10 feet of pipe),



1 | P a g e | G r a d e A + | 2 0 0 2 5

,2024/ 2025 | © copyright | This work may not be copied for profit gain Excel!
not to exceed 100 ft wc. If system is higher than 100 feet, test plugs must

be installed to facilitate testing, rarely are more than 7 stories tested at

one time. A peppermint oil test may also be done with 2 oz of

peppermint oil and 10 qt boiling water, and searching for peppermint

smell at leaks, however it is difficult to pinpoint the leak by this method




The maximum length from the vent connection to any future drain outlet is required by

code, why, how long is the distance (listed in the book), and what’s the exception?


✓ To prevent a dead end where slime, sludge and fungi can grow, 2 feet,

unless the piping must be extended to an accessible location for a

cleanout




A sanitary tee may be used in the vertical but what may not be used in the vertical and why?


✓ A double sanitary tee because the possibility of flow crossover and

excessive pressures when one branch is discharging and the other isn’t

are possible




What are the slopes of pipe inside the building that correspond to 2 fps velocity?


✓ 1/4 in per foot for 3 in and smaller 1/8 in per foot for larger pipe all

elbows, taps, tees etc are tapped at a pitch of 1/4” per foot




1 | P a g e | G r a d e A + | 2 0 0 2 5

,2024/ 2025 | © copyright | This work may not be copied for profit gain Excel!
Where should cleanouts be provided?


✓ 1) Inside or outside the building at the point of exit (use a wye branch)

2) at every change in direction greater than 45 degrees 3) every 50 feet

for piping 4” and less, and 100 ft for larger piping 4) underground

piping larger than 10 in should be provided with manhol es at every

change in direction and every 150 feet 5) at the base of all stacks 6) as

required by code




What size cleanouts are provided in piping?


✓ Piping up to 4 inches, the cleanout is the same size as the pipe. Piping

greater than 4 inches, 4 inch cleanouts are adequate.




What should be installed in the house drain if there is a danger of backflow of sewage into

the building? Whats the difference?


✓ A backwater valve or a combination BWV with manually operated gate

valve. The BWV does not inter fere with the airflow throughout the

system, and the gate valve is recommended where there is a history of

backflow as a positive means of protection.




Branch connections to the house drain should be made where and why?




1 | P a g e | G r a d e A + | 2 0 0 2 5

, 2024/ 2025 | © copyright | This work may not be copied for profit gain Excel!
✓ At the upper portion of the pipe (above the 1/2 - 2/3 full mark) because:

1) there is a lower chance of stoppages in the branch 2) there is less flow

interference at the point of connection 3) When there is no flow in the

branch, the full area of the pipe is available to relieve pneuma tic pressure

fluctuations in the house drain




How many fixture units are equivalent to 1 gpm continuous or semicontinuous flow and

what are examples of these types of flow?


✓ 2 FUs, sump pumps, ejectors, air conditioning equipment, water cooled,

equipment, etc




What minimum slopes are required for building drains and why?


✓ 3 in pipe and smaller: 1/4 in/ft 4 -6 in pipe: 1/8 in/ft 8 in pipe and larger:

1/16 in/ft to maintain 2 fps scouring action if low flow fixtures are

present, 1/4 in/ft for all is a good idea




House drains are designed to flow how full?


✓ 1/2 full to 3/4 full max under uniform flow conditions




What is a house (building) drain?




1 | P a g e | G r a d e A + | 2 0 0 2 5

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TestTrackers. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart