100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
PBCFR DRIVER Midterm Exam Questions And All Correct Answers. $10.39   Add to cart

Exam (elaborations)

PBCFR DRIVER Midterm Exam Questions And All Correct Answers.

 1 view  0 purchase
  • Course
  • PBCFR Driver Operator
  • Institution
  • PBCFR Driver Operator

Upon dispatch to an automatic fire alarm, units shall respond - Answer Code 1 Company Officers may use discretion to respond ________ based on available or updated information from the Communications Center. - Answer Code 3 If the Communications Center is notified by a monitoring company,...

[Show more]

Preview 2 out of 8  pages

  • September 25, 2024
  • 8
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • PBCFR Driver Operator
  • PBCFR Driver Operator
avatar-seller
TestSolver9
PBCFR DRIVER Midterm Exam
Questions And All Correct Answers.
Upon dispatch to an automatic fire alarm, units shall respond - Answer Code 1



Company Officers may use discretion to respond ________ based on available or updated information
from the Communications Center. - Answer Code 3



If the Communications Center is notified by a monitoring company, that a fire alarm was a false alarm
and a proper code was given, then all responding unit(s) shall - Answer Cancel



If the Communications Center is notified by a business or homeowner that there is no emergency, then
all responding unit(s)shall continue - Answer Code 1 to verify



Access should be gained when the interior of the building is - Answer not readily visible from the
exterior.



_______should be utilized when no key or key holder is available, and there are indications that an
actual fire may be present. - Answer Forcible Entry



After a thorough search of the building for a fire conditions, a fire alarm may be - Answer Silenced



The alarm annunciator panel should be located, and a check should be made for pull stations or smoke
detectors that have been activated. - Answer



Units dispatched to automatic fire alarms that are reported as water flow alarms shall respond - Answer
Code 3



When there is no indication of fire from Side Alpha, or after locating the annunciator panel, personnel
shall (3) - Answer 1.Perform a 360-degree size up

2. Locate the outside risers

, 3. Check the system to see if water is actually flowing (pressure gauges, water gong alarm, etc...).



If a water flow is confirmed, personnel shall - Answer gain access to the interior of the structure, in
order to accurately evaluate the cause of the alarm.



All buildings in the county that are equipped with fire alarm systems are also required to maintain
building access keys in a - Answer Knox Box



If a building with a fire alarm system is found to not have a Knox Box or is not operating properly, please
advise the appropriate - Answer area inspector within Bureau of Safety Services.



During an emergency or non-emergency incident, if the proper keys are not in the Knox Box, the
Company Officer should determine if a - Answer key holder can respond in a timely manner, or if there
is an immediate need to force entry.



(FIRE ALARMS) If no building representative is present, advise the Communications Center that the alarm
has been silenced. The Communications Center shall notify the monitoring company to contact the
building representative that the system needs to be serviced. - Answer



When a fire occurs in a building equipped with a fire protection system (sprinklers and/or hose cabinets)
the second arriving engine should be assigned to - Answer support these systems



(Sprinklered Buildings) The second arriving engine should connect to the Fire Department Connection
(FDC) with a minimum of - Answer two 3" supply lines and connect to a hydrant with LDH.



(Sprinklered Buildings) Supply lines shall be charged and maintained at - Answer 150 PSI



Static water sources (lakes, canals, etc.) should not be used to - Answer support fire protection systems
connected to a potable water supply.



Water needed for other firefighting activities should not - Answer diminish the water supply to the
building's fire protection system.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TestSolver9. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.39. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76669 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.39
  • (0)
  Add to cart